RBI Policies
RBI Policies
An RBI Policy allows you to develop and execute strategies based on historical data and dynamic data, which is obtained by monitoring conditions in real time. The policies used in RBI are categorized as follows:
- Policies used to calculate an analysis
- Policies used to generate recommendations
- Policies used in risk mapping
These policies appear in the Module Workflow Policies section of the Policy Designer Overview page.
Policies and RScripts used to Calculate an RBI 581 Risk Analysis
This topic provides a list of Policies and RScripts used by each family in RBI 581 to calculate an RBI 581 Risk Analysis.
If you want to design a policy, you must be a member of the following Security Groups:
-
MI Policy Designer
-and-
- MI RBI Calculation Policy Designer
If you want to view a policy, you must be a member of the following Security Groups:
-
MI Policy Viewer
-and-
- MI RBI Calculation Policy Viewer
Family: RBI 581 Cracking Damage Evaluation
The following table provides a list of Policies and RScripts that are used by RBI 581 Cracking Damage Evaluation. These RScripts are stored in the following catalog folder: Public\Meridium\Modules\Risk Based Inspection - 581\Rscripts
Degradation Mechanism | Policy | RScript Name |
---|---|---|
581-Sulfide Stress Cracking 581-HIC/SOHIC-H2S | RBI 581 Calculate Environmental Severity | None |
581-HIC/SOHIC-H2S | RBI 581 Calculate Susceptibility - HIC/SOHIC H2S | None |
581-Alkaline Carbonate Stress Corrosion Cracking | RBI 581 Calculate Susceptibility - Alkaline | None |
581-Amine Cracking | RBI 581 Calculate Susceptibility - Amine Cracking | None |
581-Caustic Cracking | RBI 581 Calculate Susceptibility - Caustic | None |
581-Chloride Stress Corrosion Cracking | RBI 581 Calculate Susceptibility - CISCC | None |
581-HIC/SOHIC-HF | RBI 581 Calculate Susceptibility - HIC/SOHIC HF | None |
581-Hydrogen Stress Cracking 581-HIC/SOHIC-HF | RBI 581 Calculate Susceptibility - HSC HF | None |
581-Polythionic Acid Cracking | RBI 581 Calculate Susceptibility - PASCC | None |
581-Sulfide Stress Cracking | RBI 581 Calculated Susceptibility - SSC | None |
Family: RBI 581 External Cracking Damage Evaluation
The following table provides a list of Policies and RScripts that are used by RBI 581 External Cracking Damage Evaluation. These RScripts are stored in the following catalog folder: Public\Meridium\Modules\Risk Based Inspection - 581\Rscripts
Degradation Mechanism | Policy | RScript Name |
---|---|---|
581-Austenitic Component Cracking Under Insulation | RBI 581 Calculate Susceptibility - Austenitic CUI | Austenitic CUI Calculate Susceptibility |
581-Austenitic Component Atmospheric Cracking | RBI 581 Calculate Susceptibility - Austenitic | None |
Family: RBI 581 Mechanical Fatigue Damage Evaluation
The following table provides a list of Policies and RScripts that are used by RBI 581 Mechanical Fatigue Damage Evaluation. These RScripts are stored in the following catalog folder: Public\Meridium\Modules\Risk Based Inspection - 581\Rscripts
Degradation Mechanism | Policy | RScript Name |
---|---|---|
581-Piping Mechanical Fatigue | RBI 581 Mechanical Fatigue Pipe Damage Evaluation | Determine Base Damage Factor For Mechanical Fatigue |
Family: RBI 581 Thinning and Lining Evaluation
The following table provides a list of Policies and RScripts that are used by RBI 581 Thinning and Lining Evaluation. These RScripts are stored in the following catalog folder: Public\Meridium\Modules\Risk Based Inspection - 581\Rscripts
Degradation Mechanism | Policy | RScript Name |
---|---|---|
581-Amine Corrosion | RBI 581 Amine Corrosion Rate | Determine Amine Corrosion for Carbon and Low Alloy Steel |
581-Acid Sour Water Corrosion | RBI 581 Acid Sour Corrosion Rate | Determine Acid Sour Velocity Factor |
581-Alkaline Sour Water Corrosion | RBI 581 Alkaline Sour Water Corrosion Rate | Alkaline Sour Water Adjusted Corrosion Rate |
581-Atmospheric Tank Bottom Corrosion | RBI 581 AST Bottom Corrosion Rate | Determine Final Corrosion Soil |
Determine Soil Multiplyfactor | ||
Final Tank Bottom Corrosion Rate | ||
RBI 581 Damage Factor - AST Bottom Thinning | Art For AST Bottom | |
Calculate Component Date in Service | ||
Final Thinning Damage Factor (AST Bottom) | ||
581-Cooling Water Corrosion | RBI 581 Cooling Water Corrosion Rate Estimation | Calculate Cooling Water Corrosion Rate |
Calculate Corrosion Rate Sea Water | ||
Calculate RSI | ||
Calculate Velocity Adj Factor | ||
581-Soil Side Corrosion | RBI 581 Soil Side Corrosion Rate Calculation | Soil Side Corrosion Rate Calculations |
Soil Side Corrosion Rate Calculations when Coating Present is NO | ||
581-High Temperature H2/H2S Corrosion | RBI 581 H2-H2S Corrosion Rate | None |
581-Sulfuric Acid Corrosion | RBI 581 H2SO4 Corrosion Rate | None |
581-Hydrochloric Acid Corrosion | RBI 581 HCL Corrosion Rate | None |
581-High Temperature Oxidation | RBI 581 HT Oxidation Corrosion Rate | None |
581-Hydrofluoric Acid Corrosion | RBI 581 Hydrofluoric Acid Corrosion Rate | None |
581-High Temperature Sulfidic and Naphthenic Acid Corrosion | RBI 581 Sulfidic and Naphthenic Corrosion Rate | None |
Policies used to Generate Recommendations
This topic has been intentionally excluded from the GE Digital APM product documentation website. This topic is available to you via the product documentation that is provided within the GE Digital APM system.
Policies used in Risk Mapping
This following policies are used in risk mapping in RBI 581:
- 581-DEF-RISK_MAPPING-OPERATIONS
- 581-DEF-RISK_MAPPING-SAFETY
If you want to design a policy, you must be a member of the following Security Groups:
-
MI Policy Designer
-and-
- RBI Risk Mapping Policy Designer
If you want to view a policy, you must be a member of the following Security Groups:
-
MI Policy Viewer
-and-
- RBI Risk Mapping Policy Viewer
Policies and Fields Used to Calculate Corrosion Rate
This topic has been intentionally excluded from the GE Digital APM product documentation website. This topic is available to you via the product documentation that is provided within the GE Digital APM system.
Policies and Fields Used to Calculate Susceptibility
This topic has been intentionally excluded from the GE Digital APM product documentation website. This topic is available to you via the product documentation that is provided within the GE Digital APM system.