The Inspection Auto-Selection feature allows you to automatically assign an Inspection to a Degradation Mechanism Evaluation (DME) in RBI 581. By default, this feature is disabled. You can enable the feature by accessing the Inspection Auto-Selection workspace.
For each DME for which you want GE Digital APM to assign Inspections automatically, an RBI Inspection Auto-Selection Criteria record must exist. This record stores the following details:
The following table provides a list of baseline RBI Inspection Auto-Selection Criteria records and their field values. You can access these records only after you enable the Inspection Auto-Selection feature.
Analysis Family | DM Methodology | Equivalent DM Methodology | Degradation Mechanism | Years of Inspection History |
---|---|---|---|---|
RBI 581 Risk Analysis | RBI 581 External Cracking Damage Evaluation | Blank | Blank | 20 |
RBI 581 Risk Analysis | RBI 581 External Damage Evaluation | Criticality Ext. Corr. Deg. Mech. Eval. | Blank | 20 |
RBI 581 Risk Analysis | RBI 581 Thinning and Lining Evaluation | Criticality Int. Corr. Deg. Mech. Eval. | Blank | 20 |
RBI 581 Risk Analysis | RBI 581 Cracking Damage Evaluation | Criticality Env. Crack. Deg. Mech. Eval. | Blank | 20 |
RBI 581 Risk Analysis | RBI 581 Thinning and Lining Evaluation | Criticality Int. Corr. Deg. Mech. Eval. | 581-Atmospheric Tank Bottom Corrosion | 20 |
When you create, duplicate, or apply an RBI 581 Risk Analysis, all the Inspections that meet the criteria specified in the RBI Inspection Auto-Selection Criteria record are assigned to the DME automatically.
The maximum number of Inspections that can be assigned to RBI 581 Cracking Damage Evaluation or RBI 581 External Cracking Damage Evaluation is six. Therefore, among the Inspections that meet the criteria specified in the RBI Inspection Auto-Selection Criteria record, only the latest six Inspections are assigned to the DME. Similarly, the maximum number of Inspections that can be assigned to the 581-Atmospheric Tank Bottom Corrosion DM is one. Therefore, only the latest Inspection (among the ones that meet the criteria) is assigned to the corresponding DME.
Note: Inspections are also assigned automatically when you create an RBI 581 Risk Analysis using the Risk Based Inspection (RBI) 581 Data Loader.
Even after you delete an RBI Inspection Auto-Selection Criteria record, Inspections are automatically assigned to a DME. These Inspections, however, are not filtered based on the criteria specified in the record.
Suppose you have created an RBI 581 Risk Analysis on 17th March, 2017, which is linked to the 581-Amine Corrosion DM.
The following RBI Criticality Auto-Selection Criteria record is used to assign Inspections to all the DMs that are linked to RBI 581 Thinning and Lining Evaluation (which includes 581-Amine Corrosion).
Field | Value |
---|---|
Analysis Family | RBI 581 Risk Analysis |
DM Methodology | RBI 581 Thinning and Lining Evaluation |
Equivalent DM Methodology | Criticality Int. Corr. Deg. Mech. Eval. |
Degradation Mechanism | Blank |
Years of Inspection History | 20 |
Suppose the following Inspections appear in the Inspection History for 581-Amine Corrosion:
Inspection ID | Inspection Confidence | Degradation Mechanism | Completion Date |
---|---|---|---|
Insp-1 | A | 581-Amine Corrosion | 06/15/2012 00:00:00 |
Insp-2 | A | 581-Cooling Water Corrosion | 08/18/2014 10:30:00 |
Insp-3 | B | Criticality Calculator Internal Corrosion | 11/25/1995 05:00:00 |
Insp-4 | C | 581-Amine Corrosion | 01/15/2000 06:00:00 |
Insp-5 | C | 581-Acid Sour Water Corrosion | 01/28/1990 04:45:00 |
Insp-6 | B | 581-High Temperature Oxidation | 06/02/2012 06:15:00 |
Insp-7 | A | Criticality Calculator Internal Corrosion | 10/13/2012 07:30:00 |
Among the Inspections in the previous table, the following Inspections are not assigned to 581-Amine Corrosion because they were completed more than 20 years ago:
The remaining Inspections are automatically assigned to 581-Amine Corrosion because they satisfy the following conditions:
Now, suppose you have created an RBI Inspection Auto-Selection Criteria record with the following details:
Field | Value |
---|---|
Analysis Family | RBI 581 Risk Analysis |
DM Methodology | RBI 581 Thinning and Lining Evaluation |
Equivalent DM Methodology | Criticality Int. Corr. Deg. Mech. Eval. |
Degradation Mechanism | 581-Amine Corrosion |
Years of Inspection History | 10 |
Suppose you have created another RBI 581 Risk Analysis on 17th March, 2017, which is linked to 581-Amine Corrosion.
In this case, only Insp-1 will be assigned to 581-Amine Corrosion. Although Insp-4 is also linked to 581-Amine Corrosion, it will not be automatically assigned to the DM because the Inspection was completed more than 10 years ago.