RBI Policies
RBI Policies
An RBI Policy allows you to develop and execute strategies based on historical data and dynamic data, which is obtained by monitoring conditions in real time. The policies used in RBI are categorized as follows:
- Policies used to calculate an analysis
- Policies used to generate recommendations
- Policies used in risk mapping
These policies appear in the Module Workflow Policies section of the Policy Designer Overview page.
Policies used to Calculate an RBI 581 Risk Analysis
This topic provides a list of Policies used by each family in RBI 581 to calculate an RBI 581 Risk Analysis.
If you want to design a policy, you must be a member of the following Security Groups:
-
MI Policy Designer
-and-
- MI RBI Calculation Policy Designer
If you want to view a policy, you must be a member of the following Security Groups:
-
MI Policy Viewer
-and-
- MI RBI Calculation Policy Viewer
Family: RBI 581 Cracking Damage Evaluation
Degradation Mechanism | Policy |
---|---|
581-Sulfide Stress Cracking 581-HIC/SOHIC-H2S | RBI 581 Calculate Environmental Severity |
581-HIC/SOHIC-H2S | RBI 581 Calculate Susceptibility - HIC/SOHIC H2S |
581-Alkaline Carbonate Stress Corrosion Cracking | RBI 581 Calculate Susceptibility - Alkaline |
581-Amine Cracking | RBI 581 Calculate Susceptibility - Amine Cracking |
581-Caustic Cracking | RBI 581 Calculate Susceptibility - Caustic |
581-Chloride Stress Corrosion Cracking | RBI 581 Calculate Susceptibility - CISCC |
581-HIC/SOHIC-HF | RBI 581 Calculate Susceptibility - HIC/SOHIC HF |
581-Hydrogen Stress Cracking 581-HIC/SOHIC-HF | RBI 581 Calculate Susceptibility - HSC HF |
581-Polythionic Acid Cracking | RBI 581 Calculate Susceptibility - PASCC |
581-Sulfide Stress Cracking | RBI 581 Calculated Susceptibility - SSC |
Family: RBI 581 External Cracking Damage Evaluation
The following table provides a list of Policies that are used by RBI 581 External Cracking Damage Evaluation.
Degradation Mechanism | Policy |
---|---|
581-Austenitic Component Cracking Under Insulation | RBI 581 Calculate Susceptibility - Austenitic CUI |
581-Austenitic Component Atmospheric Cracking | RBI 581 Calculate Susceptibility - Austenitic |
Family: RBI 581 Mechanical Fatigue Damage Evaluation
The following table provides a list of Policies that are used by RBI 581 Mechanical Fatigue Damage Evaluation.
Degradation Mechanism | Policy |
---|---|
581-Piping Mechanical Fatigue | RBI 581 Mechanical Fatigue Pipe Damage Evaluation |
Family: RBI 581 Thinning and Lining Evaluation
The following table provides a list of Policies that are used by RBI 581 Thinning and Lining Evaluation.
Degradation Mechanism | Policy |
---|---|
581-Amine Corrosion | RBI 581 Amine Corrosion Rate |
581-Acid Sour Water Corrosion | RBI 581 Acid Sour Corrosion Rate |
581-Alkaline Sour Water Corrosion | RBI 581 Alkaline Sour Water Corrosion Rate |
581-Atmospheric Tank Bottom Corrosion | RBI 581 AST Bottom Corrosion Rate |
RBI 581 Damage Factor - AST Bottom Thinning | |
581-Cooling Water Corrosion | RBI 581 Cooling Water Corrosion Rate Estimation |
581-Soil Side Corrosion | RBI 581 Soil Side Corrosion Rate Calculation |
581-High Temperature H2/H2S Corrosion | RBI 581 H2-H2S Corrosion Rate |
581-Sulfuric Acid Corrosion | RBI 581 H2SO4 Corrosion Rate |
581-Hydrochloric Acid Corrosion | RBI 581 HCL Corrosion Rate |
581-High Temperature Oxidation | RBI 581 HT Oxidation Corrosion Rate |
581-Hydrofluoric Acid Corrosion | RBI 581 Hydrofluoric Acid Corrosion Rate |
581-High Temperature Sulfidic and Naphthenic Acid Corrosion | RBI 581 Sulfidic and Naphthenic Corrosion Rate |
Policies used to Generate Recommendations
This topic provides a list of Policies that are used to generate Recommendations in RBI 581.
If you want to design a policy, you must be a member of the following Security Groups:
-
MI Policy Designer
-and-
- MI RBI Recommendation Policy Designer
If you want to view a policy, you must be a member of the following Security Groups:
-
MI Policy Viewer
-and-
- MI RBI Recommendation Policy Viewer
Component Type: Storage Tank
The following table lists the policies that are used by components of type Storage Tank, the DMs that are applicable to use the policy, and the fields that are used in the policy.
Policy | Fields used by the Policy (Family Name) | Applicable Degradation Mechanisms |
---|---|---|
RBI 581 Tank Shell Ext Corrosion Recommendation |
| All DMs related to RBI 581 External Damage Evaluation |
RBI 581 Tank Shell Int Corrosion Recommendation |
| All DMs related to RBI 581 Thinning and Lining Evaluation except 581- Atmospheric Storage Tank Bottom |
Component Type: Storage Tank Bottom
The following table lists the policies that are used by components of type Storage Tank Bottom, the DMs that are applicable to use the policy, and the families that use the policy.
Policy | Fields used by the Policy (Family Name | Applicable Degradation Mechanisms |
---|---|---|
RBI 581 Tank Bottom Insp Recommendation |
|
|
Other Component Types
The following table lists the policies that are used by components other than Storage Tank, Storage Tank Bottom, and Heat Exchangers, the DMs that are applicable to use the policy, and the families that use the policy.
Policy | Fields used by the Policy (Family Name) | Applicable Degradation Mechanisms |
---|---|---|
RBI 581 Thinning and Lining Insp Recommendation |
| All DMs related to RBI 581 Thinning and Lining Evaluation except 581- Atmospheric Storage Tank Bottom |
RBI 581 External Damage Inspection Recommendation |
| All DMs related to RBI 581 External Cracking Damage Evaluation All DMs related to RBI 581 External Damage Evaluation |
RBI 581 Env Cracking Insp Recommendation |
| All DMs related to RBI 581 Cracking Damage Evaluation |
Policies used in Risk Mapping
This following policies are used in risk mapping in RBI 581:
- 581-DEF-RISK_MAPPING-OPERATIONS
- 581-DEF-RISK_MAPPING-SAFETY
If you want to design a policy, you must be a member of the following Security Groups:
-
MI Policy Designer
-and-
- RBI Risk Mapping Policy Designer
If you want to view a policy, you must be a member of the following Security Groups:
-
MI Policy Viewer
-and-
- RBI Risk Mapping Policy Viewer
Policies and Fields Used to Calculate Corrosion Rate
The following table provides a list of policies that are used and fields that are required to calculate the corrosion rate for each DM related to RBI 581 Thinning and Lining Evaluation.
Damage Mechanism | Policy Name | Field | Family |
---|---|---|---|
581-Hydrochloric Acid Corrosion | RBI 581 HCL Corrosion Rate | Is Air or Oxident Present? | RBI 581 Thinning and Lining Evaluation |
pH of Water | RBI 581 Risk Analysis | ||
Operating Temperature | RBI 581 Risk Analysis | ||
581-High Temperature Sulfidic and Naphthenic Acid | RBI 581 Sulfidic and Naphthenic Corrosion Rate | Total Acid Number | RBI 581 Thinning and Lining Evaluation |
Sulphur Concentration | RBI 581 Thinning and Lining Evaluation | ||
Fluid Velocity | RBI 581 Risk Analysis | ||
Operating Temperature | RBI 581 Risk Analysis | ||
581-High Temperature H2/H2S Corrosion | RBI 581 H2-H2S Corrosion Rate | H2/H2S Content | RBI 581 Thinning and Lining Evaluation |
Hydrocarbon Type | RBI 581 Thinning and Lining Evaluation | ||
Operating Temperature | RBI 581 Risk Analysis | ||
581-Sulfuric Acid Corrosion | RBI 581 H2SO4 Corrosion Rate | Acid Concentration | RBI 581 Thinning and Lining Evaluation |
Is Air or Oxident Present? | RBI 581 Thinning and Lining Evaluation | ||
Operating Temperature | RBI 581 Risk Analysis | ||
Fluid Velocity | RBI 581 Risk Analysis | ||
581-High Temperature Oxidation | RBI 581 HT Oxidation Corrosion Rate | Is Air or Oxident Present? | RBI 581 Thinning and Lining Evaluation |
Operating Temperature | RBI 581 Risk Analysis | ||
581-Acid Sour Water Corrosion | RBI 581 Acid Sour Corrosion Rate | Oxygen in the Process Stream | RBI 581 Thinning and Lining Evaluation |
Operating Temperature | RBI 581 Risk Analysis | ||
pH of Water | RBI 581 Risk Analysis | ||
Fluid Velocity | RBI 581 Risk Analysis | ||
581-Amine Corrosion | RBI 581 Amine Corrosion Rate | Acid Gas Loading | RBI 581 Thinning and Lining Evaluation |
Amine Concentration | RBI 581 Thinning and Lining Evaluation | ||
Amine Type | RBI 581 Thinning and Lining Evaluation | ||
Heat Stable Amine Salts(HSAS) | RBI 581 Thinning and Lining Evaluation | ||
Operating Temperature | RBI 581 Risk Analysis | ||
Fluid Velocity | RBI 581 Risk Analysis | ||
581-Soil Side Corrosion | RBI 581 Soil Side Corrosion Rate Calculation | Cathodic Protection Effectiveness | RBI 581 Thinning and Lining Evaluation |
Coating Type | RBI 581 Thinning and Lining Evaluation | ||
Maximum Coating Temperature Rating Exceeded? | RBI 581 Thinning and Lining Evaluation | ||
Soil Resistivity | RBI 581 Thinning and Lining Evaluation | ||
Soil Type | RBI 581 Thinning and Lining Evaluation | ||
Coating Maintenance Rare or None? | RBI 581 Thinning and Lining Evaluation | ||
Coating Age | RBI 581 Thinning and Lining Evaluation | ||
Coating Present? | RBI 581 Thinning and Lining Evaluation | ||
Operating Temperature | RBI 581 Risk Analysis | ||
581-Alkaline Sour Water Corrosion | RBI 581 Alkaline Sour Water Corrosion Rate | NH4HS concentration | RBI 581 Thinning and Lining Evaluation |
H2S Partial pressure | RBI 581 Thinning and Lining Evaluation | ||
Fluid Velocity | RBI 581 Risk Analysis | ||
581-Hydrofluoric Acid Corrosion | RBI 581 Hydrofluoric Acid Corrosion Rate | HF Concentration | RBI 581 Thinning and Lining Evaluation |
Is Air or Oxident Present? | RBI 581 Thinning and Lining Evaluation | ||
Fluid Velocity | RBI 581 Risk Analysis | ||
Operating Temperature | RBI 581 Risk Analysis | ||
581-Atmospheric Tank Bottom Corrosion | RBI 581 AST Bottom Corrosion Rate | Soil Resistivity | RBI 581 Thinning and Lining Evaluation |
AST Pad | RBI 581 Thinning and Lining Evaluation | ||
AST Drainage | RBI 581 Thinning and Lining Evaluation | ||
AST Bottom Type | RBI 581 Thinning and Lining Evaluation | ||
AST Steam Coil Heater | RBI 581 Thinning and Lining Evaluation | ||
Cathodic Protection | RBI 581 Thinning and Lining Evaluation | ||
Product Side Condition | RBI 581 Thinning and Lining Evaluation | ||
Water Product Draws | RBI 581 Thinning and Lining Evaluation | ||
Thinning Type | RBI 581 Thinning and Lining Evaluation | ||
Has Release Prevention Barrier? | RBI 581 Risk Analysis | ||
Component Type | RBI 581 Risk Analysis | ||
GFF Component Type | RBI 581 Risk Analysis | ||
Operating Temperature | RBI 581 Risk Analysis | ||
581-Cooling Water Corrosion | RBI 581 Cooling Water Corrosion Rate Estimation | Recirculating System Type | RBI 581 Thinning and Lining Evaluation |
Cooling System Type | RBI 581 Thinning and Lining Evaluation | ||
Water Type | RBI 581 Thinning and Lining Evaluation | ||
Water Treatment Type | RBI 581 Thinning and Lining Evaluation | ||
Calcium Hardness | RBI 581 Thinning and Lining Evaluation | ||
Total Dissolved Solids | RBI 581 Thinning and Lining Evaluation | ||
MO Alkalinity | RBI 581 Thinning and Lining Evaluation | ||
Cl Concentration | RBI 581 Thinning and Lining Evaluation | ||
Fluid Velocity | RBI 581 Risk Analysis | ||
pH of Water | RBI 581 Risk Analysis | ||
Operating Temperature | RBI 581 Risk Analysis |
Policies and Fields Used to Calculate Susceptibility
The following table provides a list of policies that are used and fields that are required to calculate susceptibility for each DM related to RBI 581 Cracking Damage Evaluation.
Damage Mechanism | Policy Name | Field | Family |
---|---|---|---|
581-Amine Cracking | RBI 581 Calculate Susceptibility – Amine Cracking | Amine Solution Type | RBI 581 Cracking Damage Evaluation |
Amine Type | RBI 581 Cracking Damage Evaluation | ||
Heat Traced? | RBI 581 Cracking Damage Evaluation | ||
Steam Out? | RBI 581 Cracking Damage Evaluation | ||
Operating Temperature | RBI 581 Risk Analysis | ||
581-Alkaline Carbonate Stress Corrosion Cracking | RBI 581 Calculate Susceptibility – Alkaline | CO3 Concentration in Water | RBI 581 Cracking Damage Evaluation |
pH of Water | RBI 581 Risk Analysis | ||
581-Caustic Cracking | RBI 581 Calculate Susceptibility – Caustic | Heat Traced? | RBI 581 Cracking Damage Evaluation |
Steam Out? | RBI 581 Cracking Damage Evaluation | ||
Caustic Type | RBI 581 Cracking Damage Evaluation | ||
NaOH Caustic Concentration | RBI 581 Cracking Damage Evaluation | ||
581-Chloride Stress Corrosion Cracking | RBI 581 Calculate Susceptibility – CISCC | Chloride Concentration Water Process | RBI 581 Cracking Damage Evaluation |
Operating Temperature | RBI 581 Risk Analysis | ||
pH of Water | RBI 581 Risk Analysis | ||
581-Polythionic Acid Cracking | RBI 581 Calculate Susceptibility – PASCC | Exposure to Oxygen During Operation/Downtime | RBI 581 Cracking Damage Evaluation |
Exposure to Sulfur During Operation/Downtime | RBI 581 Cracking Damage Evaluation | ||
Exposure to Water During Operation/Shutdown | RBI 581 Cracking Damage Evaluation | ||
Downtime Protection Used | RBI 581 Cracking Damage Evaluation | ||
Thermal History (Heat Treatment History) | RBI 581 Cracking Damage Evaluation | ||
Operating Temperature | RBI 581 Risk Analysis | ||
Base Material | RBI 581 Risk Analysis | ||
581-Hydrogen Stress Cracking | RBI 581 Calculate Susceptibility – HSC HF | HF Present? | RBI 581 Cracking Damage Evaluation |
Maximum Brinnell Hardness | RBI 581 Cracking Damage Evaluation | ||
Base Material | RBI 581 Risk Analysis | ||
581-HIC/SOHIC - HF | RBI 581 Calculate Susceptibility – HIC/SOHIC HF | HF Present? | RBI 581 Cracking Damage Evaluation |
Sulfur Content of Steel | RBI 581 Cracking Damage Evaluation | ||
Product Form | RBI 581 Cracking Damage Evaluation | ||
Base Material | RBI 581 Risk Analysis | ||
581-HIC/SOHIC - H2S | RBI 581 Calculate Susceptibility – HIC/SOHIC H2S | H2S Water Content | RBI 581 Cracking Damage Evaluation |
Sulfur Content of Steel | RBI 581 Cracking Damage Evaluation | ||
Product Form | RBI 581 Cracking Damage Evaluation | ||
pH of Water | RBI 581 Risk Analysis | ||
581-Sulfide Stress Cracking | RBI 581 Calculate Susceptibility – SSC | H2S Water Content | RBI 581 Cracking Damage Evaluation |
Maximum Brinnell Hardness | RBI 581 Cracking Damage Evaluation | ||
pH of Water | RBI 581 Risk Analysis | ||
581-Austenitic Component Atmospheric Cracking | RBI 581 Calculate Susceptibility – Austenitic | Atmospheric Condition | RBI 581 External Cracking Damage Evaluation |
Operating Temperature | RBI 581 Risk Analysis | ||
581-Atmospheric Tank Bottom Corrosion | RBI 581 Calculate Susceptibility – Austenitic CUI | Atmospheric Condition | RBI 581 External Cracking Damage Evaluation |
Piping System Complexity | RBI 581 External Cracking Damage Evaluation | ||
Insulation Condition | RBI 581 External Cracking Damage Evaluation | ||
Chloride Free Insulation | RBI 581 External Cracking Damage Evaluation | ||
Operating Temperature | RBI 581 Risk Analysis |