Event records store information about the fields that are defined for the Primary Event and Contributing Event families in the baseline GE Digital APM database. This topic provides an alphabetical list and description of the fields that exist for the Primary Event and Contributing Event families and appear on the Event datasheet. The information in the table reflects the baseline state and behavior of these fields. The values in these fields are defined by NERC in the GADS DRI and CEA in the Generation Equipment Status ERIS. This list is not comprehensive.
This family is enabled for site filtering, which means that records in this family can be assigned to a specific site, and will then only be accessible to users who are assigned to the same site and have the appropriate license and family privileges. See the Site Filtering section of the documentation for more information on using this feature.
Field | Data Type | Description | Behavior and Usage |
---|---|---|---|
Ambiguous Date and Time Preference | Character | Identifies whether the date and time entered in the Event Start Date field occurred before or after the clock was reset. |
This field is disabled by default. This field is enabled and required when you enter an ambiguous date and time in one of the following fields:
You can select one of following values in this field:
This field exists in the Primary Event family but not the Contributing Event family. |
Amplification Code | Character | Identifies the failure mode of the event. |
This field is enabled only when the Cause Code field is populated with a value. A baseline rule exists to populate this field with a list of values from the Amplification Code field in the Amplification Codes records. Notes: Consider the following when the Primary Event is associated with a GAA Unit in which the value in the Primary Regulatory Body field is North American Electric Reliability Corporation (NERC):
This field is required when the Primary Event is in the Unit Approved state. This field is included in NERC event reports. |
Capacity Event Type | Character |
Identifies the type of event. |
For NERC,
For CEA, this field contains a list of values defined in the GAA Event Types records.
This field excludes the Event Types based on the Unit Types that you selected in the Excluded Unit Type field in the GAA Event Types record. This field is included in NERC event reports. This field is required. |
Cause Code | Character | Identifies the cause code of the cause for the event. |
A baseline rule exists to populate this field with a list of values in fields in Cause Codes records using the format Cause Code (Cause Code Description). This field is required when the Primary Event is in the Unit Approved state. |
Cause Code Component | Character | Identifies the cause code component for the cause of the event. |
A baseline rule exists to populate this field with a list of values in the Component field in Cause Codes records. This field is required when the Primary Event is in the Unit Approved state. |
Cause Code Description | Character | Identifies the description of the cause code associated with the cause of the event. |
A baseline rule exists to populate this field with a list of values in the Cause Code Description field in Cause Codes records. This value is defined by NERC in the GADS DRI and CEA in the Generation Equipment Status ERIS. This field is required when the Primary Event is in the Unit Approved state. |
Cause Code System | Character | Identifies the system for the cause code associated with the event. |
A baseline rule exists to populate this field with a list of values in the System field in Cause Code records. This field is required when the Primary Event is in the Unit Approved state. |
Cost Calculation Status | Character | Indicates the status of the cost calculation. |
This field is populated automatically with information regarding the status of the calculation performed in the Capacity Incident Cost field. This field exists in the Primary Event family but not in the Contributing Event family. |
Count of Contributing Events |
Character | Indicates the number of Contributing Events that exist for the Primary Event. |
This field is disabled and populated automatically with a value that indicates the number of Contributing Events that are linked to the Primary Event. The value in this field is updated each time you link a new Contributing Event to the Primary Event and each time you unlink a Contributing Event from the Primary Event. This field exists in the Primary Event family but not the Contributing Event family. |
Cumulative Engine Starts at Time of Event |
Character |
Identifies the total number of engine starts the unit had experienced at the time the event occurred. |
This field is available in the Additional Reporting section for a Primary Event. |
Cumulative Fired Hours at Time of Event |
Character |
Identifies the total cumulative number of hours the unit spent generating power at the time the event occurred. |
This field is available in the Additional Reporting section for a Primary Event. |
Dominant Derate | Boolean |
Indicates whether the Event represents a dominant derate event. |
This field is enabled only when the Capacity Event Type field contains a value that identifies the event as a derate event. If the value in this field is:
This field exists in the Primary Event family but not in the Contributing Event family. |
End Date is Estimated? | Boolean |
Indicates whether the value in the Event End Date field is an estimate. |
Select this check box when the value in the Event End Date field represents an estimate of when the event ended or will end. Clear this check box if the value in the Event End Date field represents the actual time that the event ended. Note: This check box is selected automatically if you enter a future date in the Event End Date field. This field exists in the Primary Event family but not in the Contributing Event family. |
Event Contribution Code | Character |
Indicates how the incident contributed to the event. |
A baseline rule exists to populate this field with a list of System Codes in the MI_GAA_EVENT_CONTR_CODE System Code Table. You can change the value by selecting one of the following options:
This value is included in the NERC event reports. This field exists in the Contributing Event family but not in the Primary Event family. |
Event Duration | Character |
Indicates how long the event lasted. |
This field is disabled and calculated automatically using the following formula: Event End Date - Event Start Date The Event Duration takes into account any existing Daylight Saving Time Reference records for the time period between the Event Start date and Event End date. |
Event End Date | Date |
Indicates the date and time that the event ended. |
This value is included in NERC event reports. |
Event ID | Character |
|
This field is disabled and populated automatically. |
Event Number | Numeric |
Indicates the order in which the event occurred with respect to other events that exist for the same unit. |
This field does not appear on the datasheet. |
Event Start Date | Date |
Indicates the date and time that the event began. |
This value is included in NERC event reports. This field is required. |
Failure Mechanism Code | Character |
Indicates the manner in which the component failed. |
A baseline rule exists to populate this field with a list of System Codes in the MI_GM_FAILURE_MECHANISM System Code Table. This field exists in the Primary Event family but not the Contributing Event family. This field is available in the Additional Reporting section for a Primary Event. |
Gross Available Capacity | Character |
Identifies the gross available generation capacity of the unit during the event. |
|
Gross Dependable Capacity | Character | Identifies the gross dependable generation capacity of the unit at which the event occurred. |
This field is populated automatically with the value in the Gross Dependable Capacity field in the Unit Capacity record for a GAA Unit based on the start date of the Primary Event. This field exists in the Primary Event family but not the Contributing Event family. |
Gross Derate Amount | Character |
Indicates the gross amount of generation capacity that was lost during the event. |
|
Gross Maximum Capacity | Character | Identifies the gross maximum generation capacity of the unit. |
This field is populated automatically with the value in the Gross Maximum Capacity field in the Unit Capacity record for a GAA Unit based on the start date of the Primary Event. This field does not appear on the datasheet. |
Man-hours Worked | Numeric | Identifies the number of man hours that were worked correcting the cause of the event or repairing the unit. |
You can enter a value manually. |
Net Available Capacity | Character |
Identifies the net available capacity of the unit during the event. |
|
Net Dependable Capacity | Character |
Identifies the net dependable generation capacity of the unit at which the event occurred. |
This field is populated automatically with the value in the Net Dependable Capacity field in the Unit Capacity record for a GAA Unit based on the start date of the Primary Event. This field exists in the Primary Event family but not the Contributing Event family. |
Net Derate Amount | Character |
Indicates the net amount of generation capacity that was lost during the event. |
|
Net Maximum Capacity | Character | Identifies the net maximum generation capacity of the unit at which the event occurred. |
This field is populated automatically with the value in the Net Maximum Capacity field in the Unit Capacity record for a GAA Unit based on the start date of the Primary Event. This value is defined by NERC in the GADS DRI. This field does not appear on the datasheet. |
OMC Event | Boolean |
Indicates whether the event occurred for reasons that are outside of management control, such as a flood or lightning. |
If the value in this field is:
|
Potential Capacity Incident Cost | Character |
Identifies the potential cost of the event. |
This field is disabled and populated automatically with the calculated event cost, if a cost has been calculated. This field exists in the Primary Event family but not in the Contributing Event family. |
Primary Incident ID | Character | Identifies the Primary Event for which the Contributing Event exists. |
This field is disabled and populated automatically with the value in the Event ID field in the Primary Event to which the Contributing Event is linked. This field exists in the Contributing Event family but not the Primary Event family. |
Problem Alert | Boolean |
Indicates whether the problem that caused the event is the result of a design flaw or standard operating practices. |
If the value in this field is:
|
Refresh Incident Cost | Boolean |
Indicates whether the GE Digital APM system should refresh the cost calculation for the Primary Event. |
When you save the Primary Event, if the value in this field is:
This field exists in the Primary Event family but not the Contributing Event family. |
Reporting Month | Character |
Identifies the month for which the data in the Primary Event should be reported. |
This field is disabled and populated automatically with the month indicated by the value in the Event Start Date field. This field exists in the Primary Event family but not the Contributing Event family. |
Reporting Year | Numeric |
Identifies the year for which the data in the Primary Event should be reported. |
This field is disabled and populated automatically with the year indicated by the value in the Event Start Date field. This field exists in the Primary Event family but not the Contributing Event family. |
Revision | Numeric |
Identifies the revision number of the Event and should be incremented each time you re-submit a report which includes information in the Event to a Regulatory Organization. |
By default, for an Event submitted to the regulatory organization for the first time, the value in this field is set to 0. You must increase the value in this field each time you submit a report to the Regulatory Organization. |
Start Date is Estimated? | Boolean |
Indicates whether the value in the Event Start Date field is an estimate. |
Select this check box when the value in the Event Start Date field represents an estimate of when the event ended or will end. Clear this check box if the value in the Event Start Date field represents the actual time that the event ended. This field exists in the Primary Event family but not the Contributing Event family. |
Trip Mechanism | Character |
Indicates how the unit was shut down during the event. |
This field contains no value by default, and a baseline rule exists to populate this field with a list of the following values:
After you select a value in this field and save the Event record, you will not be able to clear the field. This field is available in the Additional Reporting section for a Primary Event. |
Unit ID | Character |
Identifies the Unit ID of the GAA Unit record with which the Event is associated. |
|
Unit Name | Character |
Identifies the name of the unit to which the event occurred. |
This field is disabled and populated automatically using values from Performance or GAA Unit records. |
Validate Incident | Boolean |
Indicates whether the GE Digital APM system will validate the record against all other existing Primary Events. |
When you save the Primary Event, if the value in this field is:
This field exists in the Primary Event family but not the Contributing Event family. |
Verbal Description | Character |
Describes the event. |
This field can be used to store any information about the event that is not captured in the other fields in the Event record. When you create a Primary Event, you can enter a verbal description of up to 255 characters. When you generate a NERC Event Report, the verbal description in the generated report will display only the first 84 characters of the description that you entered in the Verbal Description field. This field is required when the Primary Event is in Unit Approved state. |
Work Duration | Character |
Indicates the duration of the work that was completed as a result of the event. |
This field is disabled and populated automatically using the following formula: Work Started + Work Ended |
Work Ended | Date |
Indicates the date and time when work on the unit ended as a result of the event. |
If you enter an ambiguous date and time in this field, a message will appear and the Ambiguous Date and Time Preference field will be enabled and required. This value is included in NERC event reports. |
Work Started | Date |
Indicates the date and time when work on the unit started as a result of the event. |
If you enter an ambiguous date and time in this field, a message will appear and the Ambiguous Date and Time Preference field will be enabled and required. This value is included in NERC event reports. |