RBI 581 Data Loader

About RBI Data Loaders

APM, through the Risk Based Inspection module, provides the functionality to carry out an RBI Analysis on various types of RBI components to calculate corrosion rate, and the probability and consequence of failure, and then develop intelligent strategies. Using the RBI Data Loaders, you can generate all components for a Process Unit along with the associated analyses.

About the Risk Based Inspection (RBI) 581 Data Loader

Using the Risk Based Inspection (RBI) 581 Data Loader, you can implement Risk Based Inspection when you have RBI data in a legacy system, which is not supported by APM. To import data using the Risk Based Inspection (RBI) 581 Data Loader, APM provides an Excel template, RBI_581_Data_Loader.xlsx, which supports baseline Risk Based Inspection APM. You must export your legacy system so that the data can be used to populate the template. The data from the template will then be imported into APM using the Risk Based Inspection (RBI) 581 Data Loader.

Note: The Excel template is referred to throughout this documentation as the data loader workbook.

The data loader workbook can be used in the following scenarios:

  • Create or update components
  • Create or update analyses
  • Loading components and risk analysis data into APM so that you can retain visibility into the analysis details and calculations, and generate recommendations.
  • Calculate risk, probability and consequence of failure, and then utilize the Inspection Planning feature to mitigate the risk by the plan date.

After importing the data, the Risk Based Inspection (RBI) 581 Data Loader creates the following records in APM:

  • Criticality Calculator RBI Component
  • RBI 581 Risk Analysis
  • RBI Consequence Evaluation
  • RBI 581 Thinning and Lining Evaluation
  • RBI 581 External Damage Evaluation
  • RBI 581 External Cracking Damage Evaluation
  • RBI 581 Cracking Damage Evaluation
  • RBI 581 HTHA Damage Evaluation
  • RBI 581 Mechanical Fatigue Damage Evaluation
  • RBI 581 Brittle Fracture Damage Evaluation

The data on the (Picklist) worksheet is not loaded when you load data using the Risk Based Inspection (RBI) 581 Data Loader.

Note: This data loader workbook is not backward compatible to earlier versions of APM.

About the Risk Based Inspection (RBI) 581 Data Loader Requirements

Before you use the Risk Based Inspection (RBI) 581 Data Loader, you must complete the following steps:

  • Ensure that the RBI 581 module is deployed.
  • Ensure that the following data is present:
    • Site Reference
    • Equipment Taxonomy
    • Equipment and Functional Location Families
    • RBI Data Mapping
    • Units of Measure Conversion Sets
    • Stress Tables (APM provides Stress Tables for Pressure Vessels and Tanks. If you want to use values from these Stress Tables with the data load, you must ensure that the records are imported into your database prior to performing the data load. APM does not provide Piping Stress Tables).

    • Representative Fluids
  • If you have added custom fields to Risk Mapping families (e.g., RBI Risk Matrix Mapping, Risk Analysis Mapping), you must ensure that mappings exist for those fields, or data may not be populated as expected after the data load. This is because the Risk Based Inspection (RBI) 581 Data Loader relies on Risk Mapping families to ensure that fields on RBI 581 Risk Analysis and related records are correctly populated with data, and that resulting risk values can be mapped to the Default Risk Matrix.
  • The Security User performing the data load operation must be associated with either the MI Data Loader User or MI Data Loader Admin Security Role, and must also be associated with the MI RBI Analyst Security Group or a Security Role that is associated with this Security Group.
  • The data loader workbook contains sample data in each column. It is only for your reference. You must remove this data before using the data loader workbook.

About the Risk Based Inspection (RBI) 581 Data Loader Data Model

This topic has been intentionally excluded from the APM product documentation website. This topic is available to you via the product documentation that is provided within the APM system.

About the Risk Based Inspection (RBI) 581 Data Loader General Loading Strategy

The imported data must load in a specific sequence in order to successfully populate fields, to create records, and to link them to the predecessor and/or successor records.

Best Practices

When importing data using the Risk Based Inspection (RBI) 581 Data Loader, you must use the following best practices:

  • ID fields must not include special characters or spaces.
  • Columns (including columns representing custom fields) in the worksheets should be formatted as Text.
  • Import a maximum of 500 assets in each data load. The maximum number of records that you can load per asset using the data loader is specified in the Best Practices for Loading a Single Asset topic.
  • Do not try to create and update a component in the same data loader workbook.
  • Ensure that you enter values in cells that correspond to fields required to calculate an analysis. Otherwise, warnings will be issued in the log for the analysis and related records with invalid data.
  • When a field whose value is required based on the value in another field is blank, a warning is logged in the log file of the import job.

  • You must consider the rules described in the Workbook Layout and Use section of this document while using the Risk Based Inspection (RBI) 581 Data Loader.
  • If you have entered data related to an analysis or a DME, then you must always enter data of the associated component in the RBI_Component worksheet, even if the corresponding Criticality Calculator RBI Component record exists in the APM database.
  • You must enter a valid value in the following cells in the RBI_Component worksheet; Otherwise, the row that corresponds to that component is skipped:
    • Component ID
    • Component Type
    • Process Fluid
      Note: If the value is left blank, a valid value must be provided for each associated RBI 581 Risk Analyses.
    • GFF Component Type
      Note: If the value is left blank, a valid value must be provided for each associated RBI 581 Risk Analyses.
  • When you use the data loader to create an analysis and a cell that requires a Boolean value is blank, the corresponding field in APM is updated with the value False. When you use the data loader to update an analysis and a cell that requires a Boolean value is blank, the corresponding field in APM is not updated. Therefore, to avoid ambiguity, we recommend that you enter the valueTrue or False in the cell and not leave it blank.

  • If you want to override the default values that you have specified in the RBI 581 Admin Options workspace, you can include those values in the Risk Based Inspection (RBI) 581 Data Loader. For example, if the value for the Atmospheric Condition field for an RBI 581 External Damage Evaluation record is set to Temperate in the RBI 581 Admin Options workspace. You can override this value by entering a different value in the Atmospheric Condition cell in the DME_ExternalDamage worksheet.
  • If you want to override values that are populated from the associated component, you can include those values in the Risk Based Inspection (RBI) 581 Data Loader. For example, the value for the Operating Temperature field in an RBI 581 Risk Analysis is populated from the corresponding field in the associated RBI Component. If you want to override this value for the analysis, you must include a column for Operating Temperature in the RBI_581_Analysis worksheet in the data loader workbook, and enter the value in that cell.
  • In addition to the fields included in the Risk Based Inspection (RBI) 581 Data Loader, if you want to add values for more fields for a record, you can add columns for those fields in the appropriate worksheet.

    Note: The fields that you want to add to the data loader workbook must already exist in the corresponding family. If not, you must add the fields to the family via Configuration Manager.
  • You should not add columns that correspond to fields in the Outputs and Intermediate Outputs sections of a datasheet; Otherwise, the calculations might not be correct.
  • You should not add a column that corresponds to the Use Combined Confidence and Use Related Inspection fields to any of the following worksheets:
    • DME_Thinning

    • DME_ExternalCracking
    • DME_Cracking

      The Use Combined Confidence field is part of the integration of the Risk Based Inspection and Inspection Management modules. A value should only be set in APM.

Load Sequence

The data is loaded in the following sequence in order to create all necessary relationships between records:

  1. The Assets worksheet is processed. The Data Loader searches for the asset that corresponds to the Asset ID, Asset CMMS System, Equipment Technical Number (only for an Equipment asset) and Asset Family information that you provide in the Assets worksheet.

    If an asset specified on the worksheet does not exist, it will be skipped, as well as all entries in the subsequent worksheets corresponding to that asset.

  2. The RBI_Component worksheet is processed. The Data Loader searches for the RBI Component based on the asset data and the values in the Component and Component Type cells.

    If a component exists in the APM database, it will be updated. If not, a new component will be created, and linked to the asset.

  3. The RBI 581 Analysis worksheet is processed. For each row based on the cells specified in steps 1 and 2, a new analysis is created and linked to that component. You cannot update an analysis using the data loader workbook. The value in the Analysis Unique ID cell is not stored but will be used to identify all the Degradation Mechanism Evaluations and Consequence Evaluations specified on the subsequent worksheets that should be linked to the analysis.

    If there is invalid data for calculating an analysis, the analysis will still be loaded, but warnings will be issued in the log for all fields with incorrect values.

  4. The RBI 581 Consequence worksheet is processed. For each row based on the cells specified in steps 1 to 3, a Consequence Evaluation is created, and linked to the specified analysis.
  5. The worksheets representing Degradation Mechanism Evaluations are processed. For each row based on the cells specified in steps 1 to 3, a Degradation Mechanism Evaluation is created, and linked to the specified analysis. Additionally, for each Damage Mechanism, a corresponding Potential Degradation Mechanism is created, and linked to the component, unless a Potential Degradation Mechanism of the same type is already linked to the same component.

    When the Degradation Mechanism Evaluations are processed, if you have not included a Degradation Mechanism in the worksheet that corresponds to an existing Potential Degradation Mechanism on the component, that Potential Degradation Mechanism will be unlinked.

Data that you specify in the cells on each worksheet will be included in the records. Additionally, fields in the records will be populated with data based on your RBI Data Mapping. For example, an RBI 581 Risk Analysis will be populated with data from the RBI Component to which it is linked the same way it happens if you create the same records in APM.

Best Practices for Loading a Single Asset

For optimal performance, we recommend that you load a maximum of 14 Components with three DMEs each or 9 Components with seven DMEs. To avoid performance degradation of the data loader, you must maintain the total number of records within this limit. If you want to load more number of DMEs, you must reduce the maximum number of components.

The following tables provide illustrations of the maximum number of records that you can load per Component or Analysis, as applicable. It also provides the maximum total number of records that you can load per Asset.

Important: The numbers shown in the table are for reference purpose only, and not the maximum number of records that the data loader is designed to load. These numbers are derived based on the test results obtained from the laboratory machines. However, the performance of the data loader may vary based on the database server configuration, application server configuration, load on the servers, network speed, and other performance factors. If you find a degradation in the data loader performance, we recommend that you reduce the number of records in a single batch and upload the records in multiple batches.
Record NameAn example of the maximum number of records you can load per Asset/Component/AnalysisAn example of the total number of records you can load per Asset
RBI Component9 per Asset9
RBI 581 Risk Analysis1 per Component9
RBI 581 Consequence Evaluation1 per Analysis9
Internal DME1 per Analysis9
External DME1 per Analysis9
Cracking DME1 per Analysis9
Lining DME1 per Analysis9
External Cracking DME1 per Analysis9
HTHA DME1 per Analysis9
Brittle Fracture DME1 per Analysis9
Total number of records90

About the Risk Based Inspection (RBI) 581 Data Loader Workbook Layout and Use

To import data using the Risk Based Inspection (RBI) 581 Data Loader, APM provides an Excel workbook, Risk Based Inspection (RBI) 581.xlsx, which supports baseline Risk Based Inspection in APM. This workbook must be used to perform the data load. You can modify the Excel workbook to include custom fields used by your organization.

Note: The Excel workbook is referred to throughout this documentation as the data loader workbook.
WorksheetDescription
AssetsThis worksheet is used to specify existing Asset records to which components will be linked.
RBI_ComponentsThis worksheet is used to specify the following types of RBI Component records that will be updated or created and linked to assets.
  • Cylindrical Shell
  • Exchanger Bundle
  • Exchanger Tube
  • Piping
  • Pump Compressor Casing
  • Tank Bottom
RBI_581_AnalysisThis worksheet is used to define RBI 581 Analysis records that will be linked to components. You cannot update an RBI 581 Risk Analysis using the data loader workbook.
RBI_581_ConsequenceThis worksheet is used to define RBI 581 Consequence Evaluation records that will be linked to analyses. Each analysis can be linked to only one RBI 581 Consequence Evaluation.
DME_LiningThis worksheet is used to specify the 581-Internal Component Lining Damage DMs (which are or will be represented by the RBI 581 Thinning and Lining Evaluation records) that you want to create or update. These records will be linked to an RBI 581 Risk Analysis. You can specify these DMs only if the value in the Lining Present column is True in the RBI_Component worksheet for the associated component.
DME_AST

This worksheet is used to specify the 581-Atmospheric Tank Bottom Corrosion DMs (which are or will be represented by the RBI 581 Thinning and Lining Evaluation records) that you want to create or update. These records will be linked to an RBI 581 Risk Analysis.

You can specify these DMs only if:

  • The component family is Tank Bottom (i.e., the value in the Component Family column in the RBI_Component worksheet for the associated component is MI_CCRBICTB).
  • The value in the Is Intrusive column in the RBI_Component worksheet for the associated component is True.
DME_ThinningThis worksheet is used to specify the following DMs that you want to create or update:
  • 581-High Temperature Oxidation
  • 581-Cooling Water Corrosion
  • 581-High Temperature H2/H2S Corrosion
  • 581-Amine Corrosion
  • 581-Hydrofluoric Acid Corrosion
  • 581-Sulfuric Acid Corrosion
  • 581-Hydrochloric Acid Corrosion
  • 581-Acid Sour Water Corrosion
  • 581-High Temperature Sulfidic and Naphthenic Acid
  • 581-Alkaline Sour Water Corrosion
  • 581-Soil Side Corrosion
  • 581-Thinning Damage

These DMs belong to the RBI 581 Thinning and Lining Evaluation methodology. These records will be linked to an RBI 581 Risk Analysis.

DME_ExternalDamage

This worksheet is used to define the following DMs that you want to create or update:

  • 581-Ferritic Component Atmospheric Corrosion
  • 581-Ferritic Component Corrosion Under Insulation

These DMs belong to the RBI 581 External Damage Evaluation methodology. These records will be linked to an RBI 581 Risk Analysis. You can specify these DMs only if the component type is not Tank Bottom (i.e., the value in the Component Family column in the RBI_Component worksheet is not MI_CCRBICTB).

DME_ExternalCracking

This worksheet is used to define the following DMs that you want to create or update:

  • 581-Austenitic Component Cracking Under Insulation
  • 581-Austenitic Component Atmospheric Cracking

These DMs belong to the RBI 581 External Cracking Damage Evaluation methodology. These records will be linked to an RBI 581 Risk Analysis. You can specify these DMs only if the component type is not Tank Bottom (i.e., the value in the Component Family column in the RBI_Component worksheet is not MI_CCRBICTB).

DME_Cracking

This worksheet is used to specify the following DMs that you want to create or update:

  • 581-Amine Cracking
  • 581-Alkaline Carbonate Stress Corrosion Cracking
  • 581-HIC/SOHIC - HF
  • 581-HIC/SOHIC - H2S
  • 581-Caustic Cracking
  • 581-Hydrogen Stress Cracking
  • 581-Other Cracking
  • 581-Sulfide Stress Cracking
  • 581-Chloride Stress Corrosion Cracking
  • 581-Polythionic Acid Cracking

These DMs belong to the RBI 581 Cracking Damage Evaluation methodology. These records will be linked to an RBI 581 Risk Analysis.

DME_HTHAThis worksheet is used to specify the 581-High Temperature Hydrogen Attack DMs (which are or will be represented by the RBI 581 HTHA Damage Evaluation records) that you want to create or update. These records will be linked to an RBI 581 Risk Analysis. You can specify these DMs only if the component type is not Tank Bottom (i.e., the value in the Component Family column in the RBI_Component worksheet is not MI_CCRBICTB).
DME_MechanicalFatigueThis worksheet is used to specify the 581- Mechanical Fatigues DMs (which are or will be represented by the RBI 581 Mechanical Fatigue Damage Evaluation records) that you want to create or update. These records will be linked to an RBI 581 Risk Analysis. You can specify these DMs only if the component type is not Tank Bottom (i.e., the value in the Component Family column in the RBI_Component worksheet is not MI_CCRBICTB).
DME_BrittleFracture

This worksheet is used to specify the following DMs (which are or will be represented by the RBI 581 Brittle Fracture Damage Evaluation records) that you want to create or update.

  • 581-Sigma Phase Embrittlement
  • 581-885F Embrittlement
  • 581-Brittle Fracture
  • 581-Low Alloy Steel Embrittlement

These records will be linked to an RBI 581 Risk Analysis. You can specify these DMs only if the component type is not Tank Bottom (i.e., the value in the Component Family column in the RBI_Component worksheet is not MI_CCRBICTB).

(PickList)

This worksheet contains a list of valid values that you can enter in each column (as applicable) in the aforementioned worksheets. When you load data using the data loader, the data on this worksheet is not loaded.

The values in the some of the columns are filtered based on the values in other fields. For example, the values in the following columns are filtered based on the values in the Stress Lookup Table column:

  • BM Code
  • BM Year
  • BM Spec
  • BM Grade

Also, if you select a value in the BM Code column, the values in the BM Year, BM Spec, and BM Grade columns are filtered accordingly.

Important: The Risk Based Inspection (RBI) 581 Data Loader overrides the default values specified in the RBI 581 Admin Options workspace.

Color Coding

Certain columns on the worksheets have different functions and requirements. To illustrate this, certain columns are color-coded. The following table lists the colors and what they represent.

Color

Description

Comments

Grey 

Lookup Fields

Indicates columns that contain values that are used by the Risk Based Inspection (RBI) 581 Data Loader to look up and create records. If these columns are removed from the worksheets, the data load will fail. While the worksheets require that these columns be present, values are not necessarily required in these columns.

Red 

Fields Required for Calculation

Indicates columns that contain values that are required to perform calculations in Risk Based Inspection. Some cells only require values in certain cases. Such cases are found in parentheses in the first row of each worksheet.

Blue 

Recommended Fields

Indicates columns that, according to APM Best Practice for Risk Based Inspection, should contain values.

Green

Custom Fields

Indicates columns where you can specify custom fields.

Limitations

The Risk Based Inspection (RBI) 581 Data Loader has the following limitations:

  • You must use the data loader workbook. If you modify the format of the values in columns in any of the worksheets, you will not be able to import data.
  • Components of the Heat Exchanger - Bundle type are not supported as part of the baseline APM, but you can enter data related to the component.
  • The values that you enter in the data loader workbook are case-sensitive.
  • You cannot import data related to a custom DME using the Risk Based Inspection (RBI) 581 Data Loader. You must import only those DMEs that are included in the data loader workbook.
  • If you reimport data, the records that have been created by the Data Loader will be updated. While reimporting data, if you remove the data for a field in the data loader workbook, the value for the corresponding field in APM will not be updated.

  • You cannot create Inventory Group Configuration records, or link a Component to an inventory group using the data loader workbook.
  • When you use the data loader to create an RBI Analysis, if the value provided for the field on the Analysis, Consequence, or Degradation Mechanism Evaluation sheets is empty, the field will be skipped and the default value or the value mapped from the RBI Component will remain.
  • When you use the data loader to update an RBI Component or RBI 581 Analysis and the associated Consequence Evaluation, Damage Mechanisms, and Damage Mechanism Evaluations:

    • If a cell contains data, the value in the corresponding field will be updated in the database.
    • If a cell is blank, the value in the corresponding field will not be updated with a blank value in the database. The value that previously existed in the field is retained.
  • You cannot delete the Consequence Evaluation and the Degradation Mechanism Evaluations associated with an RBI Analysis using the data loader.
  • You can set the Event Type column to W and update an existing What-If Analysis using the data loader; however, you cannot create a new What-If Analysis. If there are more than one What-If Analyses linked to a component, you must enter a unique value in the Sub ID column.
  • The RBI 581 HE Bundle Damage Evaluation is not supported in Data Loader.

Assets Worksheet

In the Assets worksheet, you will specify assets to which you want to link components. The columns that appear on this worksheet also appear on every subsequent worksheet, and are used to identify the records that will be linked, directly or indirectly, to the assets. The combination of values in the three columns on this worksheet must be unique.

Field Caption

Field ID

Data Type (Length)

Comments

Asset ID

MI_EQUIP000_EQUIP_ID_C

Character (255)

This column requires at least one cell to have a value. For a Functional Location asset, the field MI_FNCLOC00_FNC_LOC_C must be used.

Asset CMMS System

MI_EQUIP000_SAP_SYSTEM_C

Character (255)

If the Asset record has a value in the CMMS System field, enter that value in this column. For a Functional Location asset the field MI_FNCLOC00_SAP_SYSTEM_C must be used.

Asset Family

ASSET_FAMILY_ID

Character (255)

This column is required when loading Functional Location assets. If no value is provided, the asset is considered as an Equipment asset.
Note: The following values are the valid values:
  • MI_EQUIP000
  • MI_FNCLOC00

Equipment Technical Number

MI_EQUIP000_EQUIP_TECH_NBR_C

Character (255)

If you are required to enter a value for the CMMS System cell for an equipment asset, and the Equipment has a value in the Equipment Technical Number field, enter that value in this column.

If there is no value in the CMMS System field, this column can be blank, even if the Equipment record contains a value for the Equipment Technical Number field.

Note: This field must be left blank for a Functional Location asset.

RBI_Component Worksheet

In the RBI_Component worksheet, you will specify the components (which are or will be represented by RBI Component records) that you want to create or update.

Field Caption

Field ID

Data Type (Length)

Comments

Asset ID

MI_EQUIP000_EQUIP_ID_C

Character (255)

Values in this column must match values entered in the Assets worksheet. Multiple components can be linked to the same asset (i.e., rows may have the same value in this column).

Asset CMMS System

MI_EQUIP000_SAP_SYSTEM_C

Character (255)

Values in this column must match values entered in the Assets worksheet, if they exist. Multiple components can be linked to the same asset (i.e., rows may have the same value in this column).

Equipment Technical Number

MI_EQUIP000_EQUIP_TECH_NBR_C

Character (255)

Values in this column must match values entered in the Assets worksheet, if they exist. Multiple components can be linked to the same asset (i.e., rows may have the same value in this column).

Component

MI_RBICOMPO_COMPO_C

Character (250)A value is required and must be unique. This value identifies the component.

Component Type

MI_RBICOMPO_COMPO_TYPE_C

Character (60)A value is required.

This cell may only contain one of the following values, which exist in the list in the Component Type field for RBI Component records:

  • 1" Pipe

  • 1.25" Pipe

  • 1.5" Pipe

  • 1/2" Pipe

  • 10" Pipe

  • 102" Pipe

  • 12" Pipe

  • 14" Pipe

  • 16" Pipe

  • 18" Pipe

  • 2" Pipe

  • 2.5" Pipe

  • 20" Pipe

  • 24" Pipe

  • 26" Pipe

  • 28" Pipe

  • 3" Pipe

  • 3/4" Pipe

  • 30" Pipe

  • 32" Pipe

  • 34" Pipe

  • 36" Pipe

  • 4" Pipe

  • 40" Pipe

  • 42" Pipe

  • 48" Pipe

  • 5" Pipe

  • 54" Pipe

  • 56" Pipe

  • 6" Pipe

  • 60" Pipe

  • 8" Pipe

  • 90" Pipe

  • Air Cooled Exchanger-Header

  • Air Cooled Exchanger-Tbs

  • Balanced Bellows PRD

  • Column-Bottom

  • Column-Middle

  • Column-Tank Bottom

  • Column-Top

  • Compressor

  • Conventional PRD

  • Filter

  • Fin/Fan Cooler

  • Heat Exchanger Tubes

  • Heat Exchanger-Bundle

  • Heat Exchanger-Chan

  • Heat Exchanger-Channel

  • Heat Exchanger-Shell

  • Heat Exchanger-Tubes

  • Pilot-Operated PRD

  • PRD with Rupture Disk

  • Pressure Vessel

  • Pump

  • Reactor

  • Rupture Disk Only

  • Storage Tank

  • Storage Tank Bottom

Component Family

FAMILY_ID

Character (50)

A value is required.

This cell may only contain one of the following values:

ValueComponent Family
MI_CCRBICCSCylindrical Shell
MI_CCRBICEHExchanger Header
MI_CCRBICETExchanger Tube
MI_CCRBICPIPiping
MI_CCRBIPCCPump Compressor Casing
MI_CCRBICTBTank Bottom

Component Description

MI_RBICOMPO_COMPO_DESCR_C

Character (255)None

Component Start Date

MI_RBICOMPO_COMP_STRT_DATE_DT

Date A value is required. Enter the value in the following format: YYYY-MM-DD hh:mm:ss

Circuit From

MI_CCRBICPI_CIRCU_FROM_C

Character (250)This value is applicable only if the component type is piping (i.e., the value in the Component Family cell is MI_CCRBICPI).

Circuit To

MI_CCRBICPI_CIRCU_TO_C

Character (250)This value is applicable only if the component type is piping (i.e., the value in the Component Family cell is MI_CCRBICPI).

Component Comments

MI_RBICOMPO_COMPO_COMME_TX

TextNone

Operating Pressure

MI_RBICOMPO_OPERA_PRESS_N

Numeric

A value is required.

The value in this cell is copied to the Operating Pressure field of the associated RBI Analysis.

The value in this cell is compared with the value in the Design Pressure cell for the analysis to be created.

The value in this cell must be greater than or equal to zero, and less than or equal to the value in the Design Pressure cell.

Operating Temperature

MI_RBICOMPO_OPERA_TEMPE_N

Numeric

A value is required.

The value in this cell is copied to the Operating Temperature field of the associated RBI Analysis.

The value in this cell is compared with the value in the Design Temperature cell for the analysis to be created.

If the value in the Design Temperature cell is greater than or equal to zero, the value in this cell must be less than or equal to the value in the Design Temperature cell.

If the value in the Design Temperature cell is less than zero, the analysis can be created with any value in this cell.

Foundation Type

MI_CCRBICTB_FOUND_TYPE_C

Character (50)

A value is required if the value in the Component Type cell is Storage Tank Bottom.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • Clay

  • Silt

  • Sand

  • Gravel

  • Concrete

  • Double Floor

The list in this field is populated by the FOUNDATION TYPES System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Initial Fluid Phase

MI_RBICOMPO_INIT_FLU_PHASE_C

Character (20)

A value is required.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • Liquid

  • Gas

The list in this field is populated by the FLUID TYPES System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Process Fluid

MI_RBICOMPO_PROCE_FLUID_C

Character (50)

The field is required. If the value is left blank, a valid value must be provided on the related child analysis records.

This cell may only contain a value that exists in the list in the Process Fluid field for RBI Component records. If you enter a value that is not valid for RBI 581, the Data Loader will skip that row.

If the value in the Component Type is Storage Tank Bottom, then this cell may only contain a fluid with a Dynamic Viscosity greater than 0. In the baseline APM, the following fluids have a valid Dynamic Viscosity and are supported by the Storage Tank Bottom:

  • C6-C8
  • C9-C12
  • C13-16 (Diesel)
  • C17-25 (Gas Oil)
  • C25+ (Resid)
  • H2O (Water)

Toxic Mixture

MI_RBICOMPO_TOXIC_MIX_F

Boolean

Enter True or False.

Toxic Fluid

MI_RBICOMPO_TOXIC_MODEL_C

Character (50)

A value is required if the value in the Toxic Mixture cell is True.

This cell may only contain a value that exists in the list in the Toxic Fluid field for RBI Component records.

Percent Toxic

MI_RBICOMPO_PERCE_TOXIC_N

NumericA value is required if the value in the Toxic Mixture cell is True.

Inventory

MI_RBICOMPO_INVEN_N

NumericA value is required if component type is not Tank Bottom (i.e., the value in the Component Family cell is not MI_CCRBICTB).

Inventory Group

MI_RBICOMPO_INVEN_GROUP_C

Character (50)

You cannot use this column to link the Component to an inventory group. You can link a component to an inventory group only by accessing the MI Admin Preferences page in APM.

If the Component is already linked to an inventory group, you can override the value in the Inventory Group field by entering a value in this column. However, the calculated value in the Inventory Group Mass field remains as is.

Design Pressure

MI_RBICOMPO_DESIG_PRESS_N

Numeric

A value is required if the component is linked to the following Potential Degradation Mechanisms (PDMs):

  • RBI 581 Thinning and Lining Evaluation
  • RBI 581 External Damage Evaluation

The value in this cell is copied to the Design Pressure field of the associated RBI Analysis.

The value in this cell is compared with the value in the Operating Pressure cell for the analysis to be created.

The value in this cell must be greater than or equal to zero, and greater than or equal to the value in the Operating Pressure cell.

Design Temperature

MI_RBICOMPO_DESIG_TEMPE_N

Numeric

A value is required if the component is linked to a PDM that belongs to the following DMEs:

  • RBI 581 Thinning and Lining Evaluation
  • RBI 581 External Damage Evaluation

The value in this cell is copied to the Design Temperature field of the associated RBI Analysis.

The value in this cell is compared with the value in the Operating Temperature cell for the analysis to be created.

If the value in this cell is greater than or equal to zero, the value in the Operating Temperature cell must be less than or equal to the value in this field.

If the value in this cell is less than zero, the analysis is created with any value in the Operating Temperature cell.

Diameter

MI_RBICOMPO_DIAME_INNER_N

NumericA value is required.

Length

MI_RBICOMPO_LENGT_N

Numeric

A value is required if you want to calculate inventory.

Fill HeightMI_CCRBICTB_FILL_HEIGH_NNumeric

A value is required if the value in the Component Type cell is Storage Tank Bottom or Storage Tank.

Nominal Thickness

MI_RBICOMPO_NOMIN_THICK_N

Numeric

A value is required if the component is linked to an analysis that is linked to the following damage mechanisms (DMs):

  • 581-Brittle Fracture
  • 581-Low Alloy Steel Embrittlement
  • All DMs that belong to RBI 581 Thinning and Lining Evaluation
  • All DMs that belong to RBI 581 External Damage Evaluation

Stress Lookup Table

MI_RBICOMPO_STRESS_TABLE_C

Character (50)

A value is required if the component is linked to an analysis that is linked to the following damage mechanisms (DMs):

  • 581-Brittle Fracture
  • 581-Low Alloy Steel Embrittlement
  • All DMs that belong to RBI 581 Thinning and Lining Evaluation
  • All DMs that belong to RBI 581 External Damage Evaluation

In the baseline APM system, this cell may only contain one of the following values:

  • Pressure Vessels
  • Tanks
  • Piping

If the family has been customized, the valid values could be different. This cell may only contain a value that exists in the list in the Stress Lookup Table field for RBI Component records.

BM CODE

MI_RBICOMPO_BM_CODE_C

Character (30)

A value is required if the component is linked to an analysis that is linked to the following damage mechanisms (DMs):

  • 581-Brittle Fracture
  • 581-Low Alloy Steel Embrittlement
  • All DMs that belong to RBI 581 Thinning and Lining Evaluation
  • All DMs that belong to RBI 581 External Damage Evaluation

Refer to the (Picklist) worksheet in the excel workbook for valid values that you can enter in this cell.

BM YEAR

MI_RBICOMPO_BM_YEAR_C

Character (50)

A value is required if the component is linked to an analysis that is linked to the following damage mechanisms (DMs):

  • 581-Brittle Fracture
  • 581-Low Alloy Steel Embrittlement
  • All DMs that belong to RBI 581 Thinning and Lining Evaluation
  • All DMs that belong to RBI 581 External Damage Evaluation

Refer to the (Picklist) worksheet in the excel workbook for valid values that you can enter in this cell.

BM SPEC

MI_RBICOMPO_BM_SPEC_C

Character (50)

A value is required if the component is linked to an analysis that is linked to the following damage mechanisms (DMs):

  • 581-Brittle Fracture
  • 581-Low Alloy Steel Embrittlement
  • All DMs that belong to RBI 581 Thinning and Lining Evaluation
  • All DMs that belong to RBI 581 External Damage Evaluation

Refer to the (Picklist) worksheet in the excel workbook for valid values that you can enter in this cell.

BM GRADE

MI_RBICOMPO_BM_GRADE_C

Character (50)

A value is required if the component is linked to an analysis that is linked to the following damage mechanisms (DMs):

  • 581-Brittle Fracture
  • 581-Low Alloy Steel Embrittlement
  • All DMs that belong to RBI 581 Thinning and Lining Evaluation
  • All DMs that belong to RBI 581 External Damage Evaluation

Weld Joint Effy

MI_RBICOMPO_WELD_JOINT_EFFY_N

Numeric

A value is required if the component is linked to a PDM that belongs to the following DMEs:

  • RBI 581 Thinning and Lining Evaluation
  • RBI 581 External Damage Evaluation

In the baseline APM, this cell may only contain one of the following values:

  • 0.35
  • 0.4
  • 0.45
  • 0.5
  • 0.55
  • 0.6
  • 0.65
  • 0.7
  • 0.75
  • 0.8
  • 0.85
  • 0.9
  • 0.95
  • 1

If the family has been customized, the valid values could be different. This cell may only contain a value that exists in the list in the Weld Joint Efficiency field for RBI Component records.

Insulated?

MI_RBICOMPO_INSUL_F

Boolean

Enter True or False. The value in this cell must be True if the an analysis in the component is linked to one of the following DMs:

  • 581-Ferritic Component Corrosion Under Insulation
  • 581-Austenitic Component Cracking Under Insulation
Insulation TypeMI_RBICOMPO_INSUL_CCharacter (200)

A value is required if the value in the Insulated? cell is True.

This cell may only contain one of the following values, which exist in the list in the Insulation Type field for RBI Component records:

  • Asbestos
  • Calcium Silicate (Cl Free)
  • Calcium Silicate (Not Cl Free)
  • Foam/Cellular Glass
  • Mineral Wool/Fiber Glass
  • Pearlite
  • Unknown

If the family has been customized, the valid values could be different. This cell may only contain a value that exists in the list in the Insulation Type field for RBI Component records.

Injection Point DataMI_CCRBICPI_INJ_PT_CIR_CCharacter (50)A value is required if the component type is Piping (i.e., the value in the Component Family cell is CCRBICPI).
Piping Circuit LengthMI_CCRBICPI_PIP_CIR_LENG_NNumeric

A value is required if:

  • The component type is Piping (i.e., the value in the Component Family cell is MI_CCRBICPI).

    -and-

  • The value in the Use Calculate Inventory cell in the RBI_581_Consequence worksheet is True.
PWHTMI_RBICOMPO_PWHT_FBooleanEnter True or False.
Internal Corrosion Type MI_RBICOMPO_INTER_CORR_TYPE_CCharacter (50)

A value is required if component is linked to RBI 581 Thinning and Lining Evaluation.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • General
  • Localized
  • Pitting

The list in this field is populated by the CORROSION TYPES System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in yourAPM system, via Configuration Manager, refer to the appropriate table.

Predictable Int. Corr. LocationMI_CCRBICOM_PRED_INT_COR_LOC_FBooleanEnter True or False.
Estimated Internal Corrosion RateMI_RBICOMPO_EXP_INT_CORR_RT_NNumeric

A value is required if:

  • The component is linked to the 581 Internal Component Lining Damage DM.

    -and-

  • The value in the Selected Base Material Corrosion Rate cell in the linked DM is Estimated Rate.
Estimated External Corrosion RateMI_RBICOMPO_EXP_EXT_CORR_RT_NNumeric

A value is required if:

  • The component is linked to a PDM that belongs to RBI 581 External Cracking Damage Evaluation or RBI 581 External Corrosion Damage Evaluation.

    -and-

  • The value in the Selected External Corrosion Rate cell for the associated DMs is Estimated.
Measured External Corrosion RateMI_RBICOMPO_MEAS_EXT_COR_RT_NNumericNone
Source of Calculated Corrosion RatesMI_CCRBICOM_CALCD_CR_SRC_CCharacter (50)

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • ASSET
  • COMPONENT
  • MANUAL

The list in this field is populated by the MI_RBI_CALC_CORRO_SRC System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Percent Liquid VolumeMI_RBICOMPO_PER_LIQ_VOL_NNumeric

A value is required if you want to calculate inventory.

Detection SystemMI_CCRBICOM_DETECTION_SYSTEM_CCharacter (4)

A value is required.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDDetection System
ALoss Of Pressure Or Flow
BPressure Envelope
CVisual Detection

The list in this field is populated by the 581_Detection System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Isolation SystemMI_CCRBICOM_ISOLA_SYSTE_CHRCharacter (50)

A value is required.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDIsolation System
AAuto Shutdown
BLeakage Shutdown (This value is valid only if the value in the Detection System cell is B or C).
CManual Shutdown (This value is valid only if the value in the Detection System cell is C).

The list in this field is populated by the 581_Isolation System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Mitigation SystemMI_CCRBICOM_MITIGATION_SYSTM_CCharacter (60)

A value is required.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDMitigation System
1Inventory blowdown
2Fire water deluge system
3Fire water monitors only
4Foam spray system
5No mitigation system

The list in this field is populated by the 581_Mitigation_System System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Fluid VelocityMI_CCRBICOM_FLUID_VELOCITY_NNumeric

A value is required if an analysis in the component is linked to any of the following DMs:

  • 581-Acid Sour Water Corrosion
  • 581-Hydrofluoric Acid Corrosion
  • 581-Amine Corrosion
  • 581-Cooling Water Corrosion
  • 581-High Temperature Sulfidic and Naphthenic Acid
  • 581-Sulfuric Acid Corrosion
  • 581-Alkaline Sour Water Corrosion
pH of WaterMI_CCRBICOM_PH_OF_WATER_NNumeric

A value is required if an analysis in the component is linked to any of the following DMs:

  • 581-Acid Sour Water Corrosion
  • 581-Cooling Water Corrosion
  • 581-Hydrochloric Acid Corrosion
  • 581-Alkaline Carbonate Stress Corrosion Cracking

  • 581-Chloride Stress Corrosion Cracking

  • 581-HIC/SOHIC - H2S

  • 581-Sulfide Stress Cracking

Geometry Type MI_CCRBICOM_GEOMETRY_TYPE_CCharacter (60)

A value is required if the component is linked to any of the following PDMs:

  • RBI 581 Thinning and Lining Evaluation
  • RBI 581 External Corrosion Damage Evaluation

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDGeometry Type
CYLCylinder
SPHSpherical Head
HEMHemispherical Head
PIPEPiping
HEADHead
PLTPLT (only if the value in the Component Family cell is MI_CCRBICTB)
ELLElliptical Head
RECTRectangular Cross Section

The list in this field is populated by the MI_581_Component_Geometry_Types System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

GFF Component TypeMI_CCRBICOM_GFF_COMPO_TYPE_CHRCharacter (50)

A value is required.

This cell may only contain one of the following values, which exist in the list in the GFF Component Type field for RBI Component records:

ValueGeneral Fail Frequency (GFF) Component Type
COLBTMVessel/FinFan
COLMIDVessel/FinFan
COLTOPVessel/FinFan
COMPCCompressor
COMPRCompressor
COURSE-1-10Tank650 (only for an AST Shell component)
DRUMVessel/FinFan
FILTERVessel/FinFan
FINFANVessel/FinFan
HEXSSHeat Exchanger
HEXTSHeat Exchanger
KODRUMVessel/FinFan
PIPE-1Pipe
PIPE-10Pipe
PIPE-12Pipe
PIPE-16Pipe
PIPE-2Pipe
PIPE-4Pipe
PIPE-6Pipe
PIPE-8Pipe
PIPEGT16Pipe
PUMP1SPump
PUMP2SPump
PUMPRPump
REACTORVessel/FinFan
TANKBOTTOMTank650 (only if the value in the Component Family cell is MI_CCRBICTB)
Cladding PresentMI_CCRBICOM_CLADDING_PRESENT_LCharacter (50)

A value is required if an associated analysis is linked to any of the following DMs:

  • 581-HIC/SOHIC – HF

  • 581-Hydrogen Stress Cracking

  • 581-Polythionic Acid Cracking

  • All DMs that belong to RBI 581 Thinning and Lining Evaluation

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDCladding Present
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Furnished Cladding ThicknessMI_CCRBICOM_CHRNumericA value is required if the value in the Cladding Present cell is Y.
Minimum Structural Thickness MI_CCRBICOM_MNMM_STRCTRL_THS_NNumeric

A value is required if the component is linked to any of the following PDMs:

  • RBI 581 Thinning and Lining Evaluation
  • RBI 581 External Corrosion Damage Evaluation
Liner Present MI_CCRBICOM_LINER_PRESE_CHRCharacter (50)

A value is required if the component is linked to the RBI 581 Thinning and Lining Evaluation PDM.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDLiner Present
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

For the 581-Internal Component Lining Damage DM, the value in this cell must be Yes.

Liner TypeMI_CCRBICOM_LINER_TP_CCharacter (50)

A value is required if the value in the Liner Present cell is Y.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDLiner Type
1Strip Lined Alloy
2Organic Coating (typically > 0.762mm / 30 mils)
3Thermal Resistant Service - Castable Refractory
6Severe/Abrasive Service - Castable Refractory
8Glass Linings
10Fiberglass

The list in this field is populated by the MI_581_Lining_Types_And_Resistance System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Has Release Prevention Barrier? MI_CCRBICTB_HAS_RELEA_PREVE_FBoolean

A value is required if the value in the Component Type cell is Storage Tank Bottom.

Enter True or False. If you enter True, then after you load data, the value in the Maximum Fill Height in AST field is populated with the value 0.25 feet.

CM Corrosion Rate MI_CCRBICOM_CM_COR_RT_CNumeric

A value is required if:

  • The value in the Cladding Present cell is Y.
  • The value in the Cladding Material Corrosion Rate is Estimated.
Corrosion AllowMI_RBICOMPO_CORRO_ALLOW_NNumericNone
Is Intrusive?MI_RBICOMPO_IS_INTRU_CHRCharacter (50)

A value is required if an analysis in the component is linked to any of the following DMs:

  • 581-High Temperature Oxidation
  • 581-Cooling Water Corrosion
  • 581-High Temperature H2/H2S Corrosion
  • 581-Amine Corrosion
  • 581-Hydrofluoric Acid Corrosion
  • 581-Sulfuric Acid Corrosion
  • 581-Hydrochloric Acid Corrosion
  • 581-Acid Sour Water Corrosion
  • 581-High Temperature Sulfidic and Naphthenic Acid
  • 581-Alkaline Sour Water Corrosion
  • 581-Soil Side Corrosion
  • 581-Thinning Damage
  • All DMs that belong to RBI 581 Cracking Damage Evaluation
  • All DMs that belong to RBI 581 External Cracking Damage Evaluation
  • All DMs that belong to RBI 581 External Damage Evaluation
Specified TminMI_CCRBICOM_SPECIFIED_TMIN_NNumericA value is required if the value in the Override Minimum Thickness cell is True.
Base Material MI_CCRBICOM_BASE_MATER_CCharacter (50)

A value is required if an analysis in the component is linked to any of the following DMs:

  • 581-HIC/SOHIC – HF (only if the value in the Cladding Present field is No (N))
  • 581-Hydrogen Stress Cracking (only if the value in the Cladding Present field is No (N))
  • 581-Polythionic Acid Cracking (only if the value in the Cladding Present field is No (N))
  • 581-High Temperature Hydrogen Attack
  • 581-Brittle Fracture
  • All DMs that belong to RBI 581 Thinning and Lining Evaluation

This cell may only contain one of the values that exist in the list in the Base Material field for RBI Component records.

Cladding Material MI_CCRBICOM_CLADDING_MATERIL_CCharacter (50)

A value is required if:

  • The value in the Cladding Present cell is Y.
  • An analysis in the component is linked to one of the following DMs:
    • 581-High Temperature Oxidation

    • 581-Cooling Water Corrosion

    • 581-High Temperature H2/H2S Corrosion

    • 581-Amine Corrosion

    • 581-Hydrofluoric Acid Corrosion

    • 581-Sulfuric Acid Corrosion

    • 581-Hydrochloric Acid Corrosion

    • 581-Acid Sour Water Corrosion

    • 581-High Temperature Sulfidic and Naphthenic Acid

    • 581-Alkaline Sour Water Corrosion

    • 581-Soil Side Corrosion

      581-Thinning Damage

This cell may only contain one of the values that exist in the list in the Cladding Material field for RBI Component records.

Total Acid NumberMI_CCRBICOM_TOTAL_ACID_NUMBR_NNumericA value is required if an analysis in the component is linked to the 581-High Temperature Sulfidic and Naphthenic Acid DM.

RBI_581_Analysis Worksheet

In the RBI_581_Analysis worksheet, you will specify the analyses (which will be represented by RBI 581 Risk Analysis records) that you want to create. You cannot update an RBI 581 Risk Analysis using the data loader workbook.

Field Caption

Field ID

Data Type (Length)

Comments

Asset ID

MI_EQUIP000_EQUIP_ID_C

Character (255)

Values in this column must match values entered in the Assets worksheet. Multiple analyses can be linked to the same asset (i.e., rows may have the same value in this column).

Asset CMMS System

MI_EQUIP000_SAP_SYSTEM_C

Character (255)

Values in this column must match values entered in the Assets worksheet, if they exist. Multiple analyses can be linked to the same asset (i.e., rows may have the same value in this column).

Equipment Technical Number

MI_EQUIP000_EQUIP_TECH_NBR_C

Character (255)

Values in this column must match values entered in the Assets worksheet, if they exist. Multiple components can be linked to the same asset (i.e., rows may have the same value in this column).

Component

MI_RBICOMPO_COMPO_C

Character (250)Values in this column must match values entered on the RBI_Component worksheet, if they exist. Multiple analyses can be linked to the same component (i.e., rows may have the same value in this column).

Component Type

MI_RBICOMPO_COMPO_TYPE_C

Character (60)

Values in this column must match values that you entered in the Component Type column in the RBI_Component worksheet for the associated component.

Analysis Unique IDMI_ANALYSIS_IDCharacter (255)A value is required and must be unique. This value identifies the analysis. However, in the RBI 581 Risk Analysis records that are created by the data loader in APM, the value in the Analysis ID field is different from the value that you enter in this cell.
Event TypeMI_CRITANAL_ANAL_TYPE_CCharacter (1)This column is not required. When this column exists and the value is W, the system searches for a What-If Analysis with an Analysis ID that matches the Analysis Unique ID column.
Sub IDMI_CRITANAL_SUB_ID_CCharacter (50)This column is not required.
When this column exists and the value is provided, the value must match the existing Analysis Sub ID field.
Note: The Sub ID field must be blank for analyses unless Event Type is set to W.
Scenario IDMI_CRITANAL_TURNAROUND_ID_CCharacter (50)None
Coefficient Y MaterialMI_581RANAL_COEFFICNT_Y_MTRL_CCharacter (255)

A value is required if the component type is Piping (i.e., the value in the Component Family cell is MI_CCRBICPI).

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDCoefficient Y Material
1Ferritic Steels
2Austenitic Steels
3Other Ductile Metals
4Cast Iron

The list in this field is populated by the MI_581_Coefficient_Materials System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Stress OverrideMI_581RANAL_STRES_OVER_FBooleanEnter True or False.
Allowable StressMI_CRITANAL_MTL_ALLOW_STRESS_NNumericA value is required if the value in the Stress Override cell is True.
Flow Stress MI_581RANAL_FLOW_STRESS_NNumericA value is required if the value in the Stress Override cell is True.
Override Minimum Required ThicknessMI_581RANAL_OVERR_MINIM_REQUI_THICK_FLGBooleanEnter True or False.
Course NumberMI_581RANAL_COURS_NUMBE_NBRNumericA value is required if the analysis is linked to a component of type Storage Tank (i.e., the value in the Component Type cell in the RBI_Component worksheet for the associated component is Storage Tank).

RBI_581_Consequence Worksheet

In the RBI_581_Consequence worksheet, you will specify the consequences (which are or will be represented by RBI 581 Consequence Evaluation records) that you want to create or update. You can create only one RBI 581 Consequence Evaluation for an RBI 581 Risk Analysis.

Field Caption

Field ID

Data Type (Length)

Comments

Asset ID

MI_EQUIP000_EQUIP_ID_C

Character (255)

Values in this column must match values entered on the Assets worksheet. Multiple Consequence Evaluations can be linked to the same asset (i.e., rows may have the same value in this column).

Asset CMMS System

MI_EQUIP000_SAP_SYSTEM_C

Character (255)

Values in this column must match values entered on the Assets worksheet, if they exist. Multiple Consequence Evaluations can be linked to the same asset (i.e., rows may have the same value in this column).

Equipment Technical Number

MI_EQUIP000_EQUIP_TECH_NBR_C

Character (255)

Values in this column must match values entered on the Assets worksheet, if they exist. Multiple Consequence Evaluations can be linked to the same asset (i.e., rows may have the same value in this column).

Component

MI_RBICOMPO_COMPO_C

Character (250)Values in this column must match values entered on the RBI_Component worksheet, if they exist. Multiple Consequence Evaluations can be linked to the same component (i.e., rows may have the same value in this column).

Component Type

MI_RBICOMPO_COMPO_TYPE_C

Character (60)

Values in this column must match values that you entered in the Component Type column on the RBI_Component worksheet for the associated component.

Analysis Unique IDMI_ANALYSIS_IDCharacter (255)Values in this column must match values entered on the RBI_581_Analysis worksheet. Each analysis can have only one Consequence Evaluation.
Event TypeMI_CRITANAL_ANAL_TYPE_CCharacter (1)This column is not required. The value in this column must correspond to the value entered in the Event Type column on the RBI_581_Analysis worksheet.
Sub IDMI_CRITANAL_SUB_ID_CCharacter (50)This column is not required. The value in this column must match the value entered in the Sub ID column in the RBI_581_Analysis worksheet.
ConsequenceMI_RCONEVAL_CONS_CCharacter (50)A value is required in this cell if you are creating more than one Consequence Evaluation for the same analysis. If left blank, the Consequence field will be populated with the value RBI Consequence.
Use Calculated InventoryMI_RBI_EVN0_USE_CAL_INV_LBoolean

Enter True or False.

If the value in this cell is True, values in the following cells in the RBI_Component worksheet for the associated component are required:

  • Length
  • Diameter
  • Piping Circuit Length
Inventory Group MassMI_RBI_EVN0_INV_GRP_MSS_NNumeric

A value is required if the value in the Component Family cell is not Storage Tank Bottom.

Include Personnel InjuryMI_RBI_EVN0_INCLDPRSNNLNJRYG_LBooleanEnter True or False.
Injury Cost MI_RCONEVAL_INJUR_COST_NNumericA value is required if the value in the Include Personnel Injury cell is True.
Asset CostMI_RCONEVAL_EQU_COST_NNumericA value is required if the value in the Component Type cell is not Storage Tank Bottom.
Production CostMI_RCONEVAL_PROD_COST_NNumericA value is required.
Environmental Clean-up CostsMI_RBI_EVN0_ENVIR_CLEAN_COSTS_NBRNumericA value is required if the value in the Component Type cell is not Storage Tank Bottom.
Allow Override of Total Financial ConsequenceMI_RBI_EVN0_ALW_OVE_OF_TT_FC_FLAGBooleanEnter True or False.
User Total Financial ConsequencesMI_RBI_EVN0_USERTOTAL_FC_NNumericA value is required if the value in the Allow Override of Total Financial Consequence cell is True.
Cost Escalation FactorMI_RBI_EVN0_CST_ESC_FAC_NNumericIf you do not enter a value, a value of 1 is considered to calculate the consequence.
Maximum Fill Height in ASTMI_RBI_EVN0_MXM_FLL_HGT_AST_NNumeric

A value is required if, on the RBI_Component worksheet:

  • The value in the Component Type cell is Storage Tank or Storage Tank Bottom.
  • The value in the Has Release Prevention Barrier cell is False.

If, however, the value in the Has Release Prevention Barrier cell is True, after you load data, the Maximum Fill Height is AST field is populated with the value 0.25 feet irrespective of the value in this cell.

Fluid Percent Leaving Dike MI_RBI_EVN0_FLD_PRCT_LVG_DKE_NNumericA value is required if the component type is Storage Tank or component type is Storage Tank Bottom and component family is Tank Bottom (i.e., the value in the Component Family column in the RBI_Component worksheet is MI_CCRBICTB).
Fluid Percent OnsiteMI_RBI_EVN0_FLUD_PRCNT_ONSTE_NNumericA value is required if the component type is Storage Tank or component type is Storage Tank Bottom and component family is Tank Bottom (i.e., the value in the Component Family column in the RBI_Component worksheet is MI_CCRBICTB).
Fluid Percent Offsite MI_RBI_EVN0_FLD_PRCNT_OFFSTE_NNumericA value is required if the component type is Storage Tank or component type is Storage Tank Bottom and component family is Tank Bottom (i.e., the value in the Component Family column in the RBI_Component worksheet is MI_CCRBICTB).
Environmental SensitivityMI_RBI_EVN0_ENVRNMNTL_SNSTVY_CCharacter (50)

A value is required if the component type is Storage Tank or component type is Storage Tank Bottom and component family is Tank Bottom (i.e., the value in the Component Family column in the RBI_Component worksheet is MI_CCRBICTB).

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDEnvironmental Sensitivity
LLow
MMedium
HHigh

The list in this field is populated by the MI_581_Environmental_Sensitivity System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Tank Course HeightMI_RBI_EVN0_TANK_COURSE_HGHT_NNumericA value is required if the value in the Component Type cell is Storage Tank.
Distance from Tankbottom to GroundwaterMI_RBI_EVN0_DSE_FRM_TNM_GRR_NNumericA value is required if the value in the Component Type cell is Storage Tank Bottom.
Soil Type under Tank bottomMI_RBI_EVN0_SL_TYE_UNR_T_BTM_CCharacter (50)

A value is required if the value in the Component Type cell is Storage Tank Bottom.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDSoil Type
CLClay
CSCoarse Sand
CAConcrete Asphalt
FSFine Sand
GRGravel
SCSandy Clay
SLSlit
VFVery Fine Sand

The list in this field is populated by the MI_581_Soil_Types System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

DME_Lining Worksheet

On the DME_Lining worksheet, you will specify the 581-Atmospheric Tank Bottom Corrosion DMs (which are or will be represented by the RBI 581 Thinning and Lining Evaluation records) that you want to create or update. You can specify these records only if the value in the Liner Present cell in the RBI_Component worksheet for the associated component is Y.

Field Caption

Field ID

Data Type (Length)

Comments

Asset ID

MI_EQUIP000_EQUIP_ID_C

Character (255)

Values in this column must match values entered in the Assets worksheet. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column).

Asset CMMS System

MI_EQUIP000_SAP_SYSTEM_C

Character (255)

Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column).

Equipment Technical Number

MI_EQUIP000_EQUIP_TECH_NBR_C

Character (255)

Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column).

Component

MI_RBICOMPO_COMPO_C

Character (250)Values in this column must match values entered in the RBI_Component worksheet, if they exist. Multiple DMs can be linked to the same component (i.e., rows may have the same value in this column).

Component Type

MI_RBICOMPO_COMPO_TYPE_C

Character (60)

Values in this column must match values that you entered in the Component Type column in the RBI_Component worksheet for the associated component.

Analysis Unique IDMI_ANALYSIS_IDCharacter (255)Values in this column must match values entered in the RBI_581_Analysis worksheet, if they exist. Multiple DMs can be linked to the same analysis (i.e., rows may have the same value in this column).
Event TypeMI_CRITANAL_ANAL_TYPE_CCharacter (50)This column is not required. The value in this column must match the value entered in the Event Type column in the RBI_581_Analysis worksheet.
Sub IDMI_CRITANAL_SUB_ID_CCharacter (50)This column is not required. The value in this column must match the value entered in the Sub ID column in the RBI_581_Analysis worksheet.
Damage MechanismMI_RBDEMEEV_DAM_MECH_CCharacter (50)Enter 581-Internal Component Lining Damage.
Last Known Inspection DateMI_581DMCHE_LST_KNWN_INN_DTE_DDateEnter a value in the following format: YYYY-MM-DD hh:mm:ss
Online Monitoring FlagMI_581DMCHE_ONLNE_MNTRNG_FLG_CCharacter (50)

A value is required.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDOnline Monitoring Flag
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Key Process Variable? MI_581DMCHE_KEY_PROCSS_VRBLE_CCharacter (3)

A value is required if the value in the Online Monitoring Flag column is Y.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDKey Process Variable
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Electrical Resistance Probes?MI_581DMCHE_ELCTRCL_RSSE_PRS_CCharacter (3)

A value is required if the value in the Online Monitoring Flag column is Y.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDElectrical Resistance Probes
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Corrosion Coupons? MI_581DMCHE_CORROSION_COUPNS_CCharacter (3)

A value is required if the value in the Online Monitoring Flag column is Y.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDCorrosion Coupons
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Liner Installation DateMI_581THNL_LIN_INST_DT_DDate

A value is required. Enter the value in the following format: YYYY-MM-DD hh:mm:ss

Liner ConditionMI_581THNL_LINER_COND_CCharacter (50)

A value is required.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDLiner Condition
AGood
BAverage
CPoor

The list in this field is populated by the MI_581_Lining_Condition System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Immersion Grade Coating QualityMI_581THNL_IMMN_GRE_CTG_QLY_CCharacter (50)

A value is required if the liner type is organic coating (i.e., the value in the Liner Type column in the RBI_Component worksheet for the associated component is 2).

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDImmersion Grade Coating Quality
AHigh
BMerdium
CLow

The list in this field is populated by the MI_581_Coating_Quality System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

DME_AST Worksheet

In the DME_Lining worksheet, you will specify the 581-Atmospheric Tank Bottom Corrosion DM (which are or will be represented by the RBI 581 Thinning and Lining Evaluation records) that you want to create or update.

Field Caption

Field ID

Data Type (Length)

Comments

Asset ID

MI_EQUIP000_EQUIP_ID_C

Character (255)

Values in this column must match values entered in the Assets worksheet. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column).

Asset CMMS System

MI_EQUIP000_SAP_SYSTEM_C

Character (255)

Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column).

Equipment Technical Number

MI_EQUIP000_EQUIP_TECH_NBR_C

Character (255)

Values in this column must match values entered in the Assets worksheet, if they exist. Multiple components can be linked to the same asset (i.e., rows may have the same value in this column).

Component

MI_RBICOMPO_COMPO_C

Character (250)Values in this column must match values entered in the RBI_Component worksheet, if they exist. Multiple DMs can be linked to the same component (i.e., rows may have the same value in this column).

Component Type

MI_RBICOMPO_COMPO_TYPE_C

Character (60)

Values in this column must match values that you entered in the Component Type column in the RBI_Component worksheet for the associated component.

Analysis Unique IDMI_ANALYSIS_IDCharacter (255)Values in this column must match values entered in the RBI_581_Analysis worksheet, if they exist. Multiple Consequences can be linked to the same analysis (i.e., rows may have the same value in this column).
Event TypeMI_CRITANAL_ANAL_TYPE_CCharacter (1)This column is not required. The value in this column must correspond to the value entered in the Event Type column on the RBI_581_Analysis worksheet.
Sub IDMI_CRITANAL_SUB_ID_CCharacter (50)This column is not required. The value in this column must match the value entered in the Sub ID column in the RBI_581_Analysis worksheet.
Damage MechanismMI_RBDEMEEV_DAM_MECH_CCharacter (50)Enter 581-Atmospheric Tank Bottom Corrosion.
Selected Base Material Corrosion RateMI_581THNL_SELEC_BM_COR_R_CCharacter (50)

A value is required.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • Calculated Rate
  • Estimated Rate
  • Short Term Avg
  • Long Term Avg
  • Controlling Corrosion Rate

The list in this field is populated by the 581_CORR_TYPE System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Liner ConditionMI_581THNL_LINER_COND_CCharacter (50)

A value is required if the liner present is Yes (i.e., the value in the Liner Present column in the RBI_Component worksheet for the associated component is Y).

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDLiner Condition
AGood
BAverage
CPoor

The list in this field is populated by the MI_581_Lining_Condition System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Immersion Grade Coating QualityMI_581THNL_IMMN_GRE_CTG_QLY_CCharacter (50)

A value is required if the liner type is organic coating (i.e., the value in the Liner Type column in the RBI_Component worksheet for the associated component is 2).

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDImmersion Grade Coating Quality
AHigh
BMerdium
CLow

The list in this field is populated by the MI_581_Coating_Quality System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Long Term Avg Corr RateMI_581THNL_LNG_TRM_AVG_COR_R_NNumeric

A value is required if:

  • The value in the Selected Base Material Corrosion Rate column is Long Term Avg.

    -and-

  • The value in the Source of Calculated Corrosion Rates column in the RBI_Component worksheet for the associated component is MANUAL.

Short Term Avg Corr RateMI_581THNL_SHRT_TRM_AVG_COR_NNumeric

A value is required if:

  • The value in the Selected Base Material Corrosion Rate column is Short Term Avg.

    -and-

  • The value in the Source of Calculated Corrosion Rates column in the RBI_Component worksheet for the associated component is MANUAL.

Selected Cladding Material Corrosion RateMI_581THNL_SELEC_CLADD_COR_R_CCharacter (50)

A value is required if the value in the Cladding Present column in the RBI_Component worksheet for the associated component is Y.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • Calculated Rate
  • Estimated Rate
  • Short Term Avg
  • Long Term Avg
  • Controlling Corrosion Rate

The list in this field is populated by the 581_CORR_TYPE System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Thinning TypeMI_RBDEMEEV_THIN_TYPE_CCharacter (50)

A value is required.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • General
  • Localized
  • Pitting

The list in this field is populated by the CORROSION TYPES System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Highest Effective Inspection LevelMI_RBDEMEEV_HIGH_EFF_INSP_CCharacter (25)

A value is required.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDHighest Effective Inspection Level
AHighly Effective
BUsually Effective
CFairly Effective
DPoorly Effective
EIneffective (None)

The list in this field is populated by the MI_581_Inspection_Effectiveness System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Number of Highest Effective InspectionsMI_RBDEMEEV_NO_HIGH_EFF_INS_NNumericA value is required, and should be either 0 or 1. If you enter 0 in this column, then the value in the Highest Effective Inspection Level column must be E.
Welded Construction FlagMI_581DMCHE_WLDD_CNSTRCN_FLG_CCharacter (50)

A value is required.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDWelded Construction Flag
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

API 653 Maintenance FlagMI_581THNL_API_653_MNTE_FLG_LBooleanA value is required. Enter True or False.
Foundation TypeMI_581DMCHE_FOUND_TYPE_CHRCharacter (50)

A value is required.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • Clay

  • Silt

  • Sand

  • Gravel

  • Concrete

  • Double Floor

The list in this field is populated by the FOUNDATION TYPES System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Settlement Adjustment Flag MI_581DMCHE_STTLMNT_ADJT_FLG_CCharacter (3)

A value is required if the value in the Foundation Type column is not Concrete.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDSettlement Adjustment Flag
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Settlement Adjustment Inspection MI_581DMCHE_STTLMNT_ADJT_INN_CCharacter (50)

A value is required if the value in the Settlement Adjustment Flag column is Y.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDSettlement Adjustment Inspection
1Meets API 653
1.5Never Evaluated
2Exceeds API 653

The list in this field is populated by the MI_581_Recorded_Settlement_Criteria System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Online Monitoring FlagMI_581DMCHE_ONLNE_MNTRNG_FLG_CCharacter (50)

A value is required.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDOnline Monitoring Flag
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Key Process Variable? MI_581DMCHE_KEY_PROCSS_VRBLE_CCharacter (3)

A value is required if the value in the Online Monitoring Flag column is Y.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDKey Process Variable
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Electrical Resistance Probes? MI_581DMCHE_ELCTRCL_RSSE_PRS_CCharacter (3)

A value is required if the value in the Online Monitoring Flag column is Y.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDElectrical Resistance Probes
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Corrosion Coupons?MI_581DMCHE_CORROSION_COUPNS_CCharacter (3)

A value is required if the value in the Online Monitoring Flag column is Y.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDCorrosion Coupons
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Soil Resistivity MI_581THNL_SOIL_RESIS_CNumeric

A value is required if the value in the Selected Base Material Corrosion Rate cell is Calculated Rate.

AST PadMI_581THNL_AST_PAD_CCharacter (50)

A value is required if the value in the Selected Base Material Corrosion Rate cell is Calculated Rate.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • Soil With High Salt

  • Crushed Limestone

  • Native Soil

  • Construction Grade Sand

  • Continuous Asphalt

  • Continuous Concrete

  • Oil Sand

  • High Resistivity Low Chloride Sand

The list in this field is populated by the 581_AST_PAD_MAT_TYPE System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

AST DrainageMI_581THNL_AST_DRAINAGE_CCharacter (50)

A value is required if the value in the Selected Base Material Corrosion Rate cell is Calculated Rate.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • One Third Frequently Underwater
  • Storm Water Collects At AST Base
  • Storm Water Does Not Collect At AST Base

The list in this field is populated by the 581_AST_DRAINAGE_TYPE System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

AST Steam Coil HeaterMI_581THNL_AST_STEAM_CL_HTR_CCharacter (50)

A value is required if the value in the Selected Base Material Corrosion Rate cell is Calculated Rate.

In the baselineAPM system, this cell may only contain one of the following System Code IDs:

  • YES
  • NO

The list in this field is populated by the MI_581_AST_STEAMCOIL_WATERDRWASOFF System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

AST Bottom TypeMI_581THNL_AST_BOTTOM_TYPE_CCharacter (50)

A value is required if the value in the Selected Base Material Corrosion Rate cell is Calculated Rate.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • RPB Not Per API 650
  • RPB Per API 650
  • Single Bottom

The list in this field is populated by the 581_AST_BOTTOM_TYPE System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Cathodic ProtectionMI_581THNL_CATHODIC_PROTCTN_CCharacter (50)

A value is required if the value in the Selected Base Material Corrosion Rate cell is Calculated Rate.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDCathodic Protection
NoneNone
Yes Not Per API 651Yes and Not Per API 651
Yes Per API 651Yes and Per API 651

The list in this field is populated by the 581_AST_Cathodic Protection System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Product Side ConditionMI_581THNL_PRODCT_SDE_CNDTN_CCharacter (50)

A value is required if the value in the Selected Base Material Corrosion Rate cell is Calculated Rate.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • Wet
  • Dry

The list in this field is populated by the 581_Product_Side_Condition System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Water Product DrawsMI_581THNL_WATER_PRDCT_DRWS_CCharacter (50)

A value is required if the value in the Selected Base Material Corrosion Rate cell is Calculated Rate.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • YES
  • NO

The list in this field is populated by the MI_581_AST_STEAMCOIL_WATERDRWASOFF System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

DME_Thinning Worksheet

In the DME_Thinning worksheet, you will specify the following DMs (which are or will be represented by the RBI 581 Thinning and Lining Evaluation records) that you want to create or update.

  • 581-High Temperature Oxidation

  • 581-Cooling Water Corrosion

  • 581-High Temperature H2/H2S Corrosion

  • 581-Amine Corrosion

  • 581-Hydrofluoric Acid Corrosion

  • 581-Sulfuric Acid Corrosion

  • 581-Hydrochloric Acid Corrosion

  • 581-Acid Sour Water Corrosion

  • 581-High Temperature Sulfidic and Naphthenic Acid

  • 581-Alkaline Sour Water Corrosion

  • 581-Soil Side Corrosion

These DMs belong to the RBI 581 Thinning and Lining Evaluation methodology. You can specify these DMs only if the value in the Component Type cell in the RBI_Component worksheet for the associated component is not Storage Tank Bottom.

Field Caption

Field ID

Data Type (Length)

Comments

Asset ID

MI_EQUIP000_EQUIP_ID_C

Character (255)

Values in this column must match values entered in the Assets worksheet. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column).

Asset CMMS System

MI_EQUIP000_SAP_SYSTEM_C

Character (255)

Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column).

Equipment Technical Number

MI_EQUIP000_EQUIP_TECH_NBR_C

Character (255)

Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column).

Component

MI_RBICOMPO_COMPO_C

Character (250)Values in this column must match values entered in the RBI_Component worksheet, if they exist. Multiple DMs can be linked to the same component (i.e., rows may have the same value in this column).

Component Type

MI_RBICOMPO_COMPO_TYPE_C

Character (60)

Values in this column must match values that you entered in the Component Type column on the RBI_Component worksheet for the associated component.

Analysis Unique IDMI_ANALYSIS_IDCharacter (255)Values in this column must match values entered in the RBI_581_Analysis worksheet, if they exist. Multiple DMs can be linked to the same analysis (i.e., rows may have the same value in this column).
Event TypeMI_CRITANAL_ANAL_TYPE_CCharacter (1)This column is not required. The value in this column must correspond to the value entered in the Event Type column on the RBI_581_Analysis worksheet.
Sub IDMI_CRITANAL_SUB_ID_CCharacter (50)This column is not required. The value in this column must match the value entered in the Sub ID column in the RBI_581_Analysis worksheet.
Damage MechanismMI_RBDEMEEV_DAM_MECH_CCharacter (50)

In the baseline APM system, this cell may only contain one of the following values, which exist in the list in the Damage Mechanism field in the Potential Degradation Mechanisms record:

  • 581-High Temperature Oxidation

  • 581-Cooling Water Corrosion

  • 581-High Temperature H2/H2S Corrosion

  • 581-Amine Corrosion

  • 581-Hydrofluoric Acid Corrosion

  • 581-Sulfuric Acid Corrosion

  • 581-Hydrochloric Acid Corrosion

  • 581-Acid Sour Water Corrosion

  • 581-High Temperature Sulfidic and Naphthenic Acid

  • 581-Alkaline Sour Water Corrosion

  • 581-Soil Side Corrosion

  • 581-Thinning Damage
Governing Thinning Damage MechanismMI_581THNL_GOV_THIN_DMG_MECH_CCharacter (50)

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • Ammonium Bisulfide Corrosion (Alkaline Sour Water)
  • Cooling Water Corrosion
  • Dealloying
  • Decarburization
  • Erosion/Erosion-Corrosion
  • Flue Gas Dew Point Corrosion
  • Fuel Ash Corrosion
  • Galvanic Corrosion
  • Graphitic Corrosion
  • High Temperature H2/H2S
  • HCl Acid Corrosion
  • Ammonium Chloride Corrosion
  • Hydrofluoric Acid Corrosion
  • Oxidation
  • Metal Dusting
  • Microbiologically Induced Corrosion (MIC)
  • Naphthenic Acid Corrosion (NAC)
  • Nitriding
  • Phenol (Carbonic Acid) Corrosion
  • Phosphoric Acid Corrosion
  • Soil Corrosion
  • Sour Water Corrosion (Acidic)
  • Amine Corrosion
  • Sulfidation
  • Sulfuric Acid Corrosion
  • Other
  • Aqueous Organic Acid Corrosion
  • Boiler Water Condensate (BW/C) Corrosion
  • Carburization
  • Caustic Corrosion
  • Cavitation
  • CO2 Corrosion

The list in this field is populated by the MI_581_GOV_THINNING_DAMAGE System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Last Known Inspection DateMI_581DMCHE_LST_KNWN_INN_DTE_DDateEnter a value in the following format: YYYY-MM-DD hh:mm:ss
Last Known ThicknessMI_581DMCHE_LST_KNWN_THCKNSS_NNumericA value is required if you entered a value in the Last Known Inspection Date cell.
Selected Base Material Corrosion RateMI_581THNL_SELEC_BM_COR_R_CCharacter (50)

A value is required.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • Calculated Rate
  • Estimated Rate
  • Short Term Avg
  • Long Term Avg
  • Controlling Corrosion Rate

The list in this field is populated by the 581_CORR_TYPE System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Long Term Avg Corr RateMI_581THNL_LNG_TRM_AVG_COR_R_NNumeric

A value is required if:

  • The value in the Selected Base Material Corrosion Rate column is Long Term Avg.

    -and-

  • The value in the Source of Calculated Corrosion Rates column in the RBI_Component worksheet for the associated component is MANUAL.

Short Term Avg Corr RateMI_581THNL_SHRT_TRM_AVG_COR_NNumeric

A value is required if:

  • The value in the Selected Base Material Corrosion Rate column is Short Term Avg.

    -and-

  • The value in the Source of Calculated Corrosion Rates column in the RBI_Component worksheet for the associated component is MANUAL.

Selected Cladding Material Corrosion RateMI_581THNL_SELEC_CLADD_COR_R_CCharacter (50)

A value is required if the value in the Cladding Present column in the RBI_Component worksheet for the associated component is Y.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • Calculated Rate
  • Estimated Rate
  • Short Term Avg
  • Long Term Avg
  • Controlling Corrosion Rate

The list in this field is populated by the 581_CORR_TYPE System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Number of A Level InspectionsMI_581DMCHE_NMR_OF_A_LVL_INS_NNumericA value is required.
Number of B Level InspectionsMI_581DMCHE_NMR_OF_B_LVL_INS_NNumericA value is required.
Number of C Level InspectionsMI_581DMCHE_NMR_OF_C_LVL_INS_NNumericA value is required.
Number of D Level InspectionsMI_581DMCHE_NMR_OF_D_LVL_INS_NNumericA value is required.
Thinning TypeMI_RBDEMEEV_THIN_TYPE_CCharacter (50)

A value is required.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • General
  • Localized
  • Pitting

The list in this field is populated by the CORROSION TYPES System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Injection Point FlagMI_581DMCHE_INJECTIN_PNT_FLG_CCharacter (50)

A value is required if the component type is piping (i.e., the value in the Component Family column in the RBI_Component worksheet for the associated component is MI_CCRBICPI).

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDInjection Point Flag
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Injection Point InspectionMI_581DMCHE_INJCTN_PNT_INSPN_CCharacter (50)

A value is required if the value in the Injection Point Flag column is Y.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDInjection Point Inspection
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Deadleg Flag MI_581DMCHE_DEADLEG_FLAG_CCharacter (50)

A value is required if the component type is piping (i.e., the value in the Component Family column in the RBI_Component worksheet for the associated component is MI_CCRBICPI).

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDDeadleg Flag
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Deadleg InspectionMI_581DMCHE_DEADLEG_INSPECTN_CCharacter (50)

A value is required if the value in the Deadleg Flag column is Y.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDDeadleg Inspection
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Welded Construction FlagMI_581DMCHE_WLDD_CNSTRCN_FLG_CCharacter (50)

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDWelded Construction Flag
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

API 653 Maintenance FlagMI_581THNL_API_653_MNTE_FLG_LBooleanEnter True or False.
Foundation TypeMI_581DMCHE_FOUND_TYPE_CHRCharacter (50)

A value is required.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • Clay

  • Silt

  • Sand

  • Gravel

  • Concrete

  • Double Floor

The list in this field is populated by the FOUNDATION TYPES System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Settlement Adjustment Flag MI_581DMCHE_STTLMNT_ADJT_FLG_CCharacter (3)

A value is required if the value in the Foundation Type column is not Concrete.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDSettlement Adjustment Flag
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Settlement Adjustment Inspection MI_581DMCHE_STTLMNT_ADJT_INN_CCharacter (50)

A value is required if the value in the Settlement Adjustment Flag column is Y.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDSettlement Adjustment Inspection
1Meets API 653
1.5Never Evaluated
2Exceeds API 653

The list in this field is populated by the MI_581_Recorded_Settlement_Criteria System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Online Monitoring FlagMI_581DMCHE_ONLNE_MNTRNG_FLG_CCharacter (50)

A value is required.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDOnline Monitoring Flag
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Key Process Variable? MI_581DMCHE_KEY_PROCSS_VRBLE_CCharacter (3)

A value is required if the value in the Online Monitoring Flag column is Y.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDKey Process Variable
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Electrical Resistance Probes? MI_581DMCHE_ELCTRCL_RSSE_PRS_CCharacter (3)

A value is required if the value in the Online Monitoring Flag column is Y.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDElectrical Resistance Probes
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Corrosion Coupons?MI_581DMCHE_CORROSION_COUPNS_CCharacter (3)

A value is required if the value in the Online Monitoring Flag column is Y.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDCorrosion Coupons
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Cl ConcentrationMI_581THNL_HCL_CONCENTRATIN_NNumericA value is required if the value in the Damage Mechanism column is 581-Cooling Water Corrosion.
Is Air or Oxidant Present?MI_581THNL_IS_AR_OR_OXN_PRT_CCharacter (50)

A value is required if the Damage Mechanism column contains one of the following values:

  • 581-Hydrochloric Acid Corrosion
  • 581-High Temperature Oxidation
  • 581-Sulfuric Acid Corrosion
Soil ResistivityMI_581THNL_SOIL_RESIS_CNumericA value is required if the value in the Damage Mechanism column is 581-Soil Side Corrosion.
H2S ContentMI_581THNL_H2_CONTENT_NNumericA value is required if the value in the Damage Mechanism column is 581-High Temperature H2/H2S Corrosion.
Hydrocarbon TypeMI_581THNL_HYDROCARBON_TYPE_CCharacter (50)

A value is required if the value in the Damage Mechanism column is 581-High Temperature H2/H2S Corrosion.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • NAPTHA

  • GAS OIL

The list in this field is populated by the MI_581_HYDROCARBON_TYPES System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Sulphur ConcentrationMI_581THNL_SULPHUR_CNCNTRTN_NNumericA value is required if the value in the Damage Mechanism column is 581-High Temperature Sulfidic and Naphthenic Acid.
Cooling System TypeMI_581THNL_COOLI_SYSTE_TYPE_CCharacter (50)

A value is required if the value in the Damage Mechanism column is 581-Cooling Water Corrosion.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • Once-Through

  • Recirculating

The list in this field is populated by the MI_581_Cooling_System System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Water TypeMI_581THNL_WATER_TYPE_CCharacter (50)

A value is required if the value in the Cooling System Type column is Once-Through.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • Fresh Water

  • Sea Water

The list in this field is populated by the MI_581_Water_Type System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Water Treatment Type MI_581THNL_WATER_TREAT_TYPE_CCharacter (50)

A value is required if:

  • The value in the Cooling System Type column is Recirculating.

    -or-

  • The value in the Water Type column is Fresh Water.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • Treated

  • Untreated

The list in this field is populated by the MI_581_Water_Treatment_Type System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Recirculating System TypeMI_581THNL_RECIR_SYSTE_TYPE_CCharacter (50)

A value is required if the value in the Cooling System Type column is Recirculating.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • Open

  • Closed

The list in this field is populated by the MI_581_Recirculating_System System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Calcium HardnessMI_581THNL_CALCI_HARDN_NNumeric

A value is required if:

  • The value in the Cooling System Type column is Recirculating.

    -or-

  • The value in the Water Type column is Fresh Water and the value in the Water Treatment Type column is Untreated.
Total Dissolved SolidsMI_581THNL_TOTAL_DISSO_SOLID_NNumeric

A value is required if:

  • The value in the Cooling System Type column is Recirculating.

    -or-

  • The value in the Water Type column is Fresh Water and the value in the Water Treatment Type column is Untreated.
MO AlkalinityMI_581THNL_MO_ALKAL_NNumeric

A value is required if:

  • The value in the Cooling System Type column is Recirculating.

    -or-

  • The value in the Water Type column is Fresh Water and the value in the Water Treatment Type column is Untreated.
Oxygen in the Process StreamMI_581THNL_OXYGN_ADJSTT_FCR_NNumericA value is required if the value in the Damage Mechanism column is 581-Acid Sour Water Corrosion.
Acid ConcentrationMI_581THNL_ACID_CONCENTRATN_NNumericA value is required if the value in the Damage Mechanism column is 581-Sulfuric Acid Corrosion.
Soil TypeMI_581THNL_SOIL_TYPE_CCharacter (50)

A value is required if the value in the Damage Mechanism column is 581-Soil Side Corrosion.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • Sand
  • Silt
  • Clay

The list in this field is populated by the 581_Primary_Soil_Type System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Cathodic Protection EffectivenessMI_581THNL_CATHO_PROTE_EFFEC_CCharacter (50)

A value is required if the value in the Damage Mechanism column is 581-Soil Side Corrosion.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDCathodic Protection Effectiveness
Cathodic_Protection_ exists_NONACE RP0169Cathodic Protection exists not per NACE RP0169
No_Cathodic_ProtectionNo Cathodic Protection
Cathodic_Protection_TestedCathodic Protection is tested annually
No_CP_StructureNo Cathodic Protection on Structure
CP_Tested_ NACE RP0169_SupportedTested Cathodic protection NACE RP0169 supported

The list in this field is populated by the MI_581_Cathodic Protection Effectiveness Factors System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Coating Present?MI_581DMCHE_COATING_PRESENT_CCharacter (3)

A value is required if the value in the Damage Mechanism column is 581-Soil Side Corrosion.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDCoating Present?
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Coating AgeMI_581DMCHE_COATING_AGE_NNumeric

A value is required if the value in the Coating Present? column is Y.

Maximum Coating Temperature Rating Exceeded?MI_581THNL_MAXCOTEMP_EXCEE_CCharacter (50)

A value is required if the value in the Coating Present? column is Y.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDMaximum Coating Temperature Rating Exceeded?
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Coating Maintenance Rare or None? MI_581THNLCOATI_MAINT_NONE_CCharacter (50)

A value is required if the value in the Coating Present? column is Y.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDCoating Maintenance Rare or None?
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Coating TypeMI_581THNL_COATINGTYPE_CCharacter (50)

A value is required if the value in the Coating Present? column is Y.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDCoating Type
Fusn_Bnd_EpxyFusion Bonded Epoxy
Lqd_EpxyLiquid Epoxy
Asphl_EnmlAsphalt Enamel
Asphlt_MasticAsphalt Mastic
Coat_Tar_EnmlCoat Tar Enamel
Extrd_Polythln_with_mastic_rubberExtruded Polyethylene with mastic rubber
Mill_Appld_PE_Tape_with_masticMill Applied PE Tape with mastic
Field_Appld_PE_Tape_with_masticField Applied PE Tape with mastic
Three_Layer_PE_or_PPThree-Layer PE or PP

The list in this field is populated by the 581_Coating_Type System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Amine TypeMI_581THNL_AMINE_TYPE_CCharacter (50)

A value is required if the value in the Damage Mechanism column is 581-Amine Corrosion.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • MEA
  • DEA
  • MDEA

The list in this field is populated by the MI_581_Amine_Types System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Heat Stable Amine Salts(HSAS)MI_581THNL_HSAS_NNumericA value is required if the value in the Damage Mechanism column is 581-Amine Corrosion.
Acid Gas LoadingMI_581THNL_ACID_GAS_LOADING_NNumericA value is required if the value in the Damage Mechanism column is 581-Amine Corrosion.
Amine ConcentrationMI_581THNL_AMINE_CONCENTRTN_NNumericA value is required if the value in the Damage Mechanism column is 581-Amine Corrosion.
HF ConcentrationMI_581THNL_HF_CONCE_NBRNumericA value is required if the value in the Damage Mechanism column is 581-Hydrofluoric Acid Corrosion.
H2S Partial PressureMI_581THNL_H2S_PARTI_PRESS_NBRNumericA value is required if the value in the Damage Mechanism column is 581-Alkaline Sour Water Corrosion.
NH4HS ConcentrationMI_581THNL_NH4HS_CONCE_NBRNumericA value is required if the value in the Damage Mechanism column is 581-Alkaline Sour Water Corrosion.

DME_ExternalDamage Worksheet

In the DME_ExternalDamage worksheet, you can specify the following DMs that you want to create or update:

  • 581-Ferritic Component Atmospheric Corrosion

  • 581-Ferritic Component Corrosion Under Insulation

These DMs belong to the RBI 581 External Damage Evaluation methodology. These records will be linked to an RBI 581 Risk Analysis. You can specify these DMs only if the component type is not Tank Bottom (i.e., the value in the Component Family column in the RBI_Component worksheet is not MI_CCRBICTB).

Field Caption

Field ID

Data Type (Length)

Comments

Asset ID

MI_EQUIP000_EQUIP_ID_C

Character (255)

Values in this column must match values entered in the Assets worksheet. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column).

Asset CMMS System

MI_EQUIP000_SAP_SYSTEM_C

Character (255)

Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column).

Equipment Technical Number

MI_EQUIP000_EQUIP_TECH_NBR_C

Character (255)

Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column).

Component

MI_RBICOMPO_COMPO_C

Character (250)Values in this column must match values entered in the RBI_Component worksheet, if they exist. Multiple DMs can be linked to the same component (i.e., rows may have the same value in this column).

Component Type

MI_RBICOMPO_COMPO_TYPE_C

Character (60)

Values in this column must match values that you entered in the Component Type column on the RBI_Component worksheet for the associated component.

Analysis Unique IDMI_ANALYSIS_IDCharacter (255)Values in this column must match values entered in the RBI_581_Analysis worksheet, if they exist. Multiple DMs can be linked to the same analysis (i.e., rows may have the same value in this column).
Event TypeMI_CRITANAL_ANAL_TYPE_CCharacter (1)This column is not required. The value in this column must correspond to the value entered in the Event Type column on the RBI_581_Analysis worksheet.
Sub IDMI_CRITANAL_SUB_ID_CCharacter (50)This column is not required. The value in this column must match the value entered in the Sub ID column in the RBI_581_Analysis worksheet.
Damage MechanismMI_RBDEMEEV_DAM_MECH_CCharacter (50)

In the baseline APM system, this cell may only contain one of the following values, which exist in the list in the Damage Mechanism field in the Potential Degradation Mechanisms record:

  • 581-Ferritic Component Atmospheric Corrosion

  • 581-Ferritic Component Corrosion Under Insulation

Selected External Corrosion RateMI_581_XDME_SEL_EXT_CORR_RT_CCharacter (50)

A value is required.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • Estimated
  • Calculated
  • Measured

The list in this field is populated by the MI_581_Corrosion_Rate System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Base Material Measured RateMI_RBDEMEEV_BM_MEASU_RT_NNumericA value is required if the value in the Selected External Corrosion Rate cell is Estimated.
Thinning TypeMI_RBDEMEEV_THIN_TYPE_CCharacter (50)

A value is required.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • General
  • Localized
  • Pitting

The list in this field is populated by the CORROSION TYPES System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Coating Present?MI_581DMCHE_COATING_PRESENT_CCharacter (3)

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDCoating Present?
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Coating Installation DateMI_581DMCHE_CTNG_INSTLLN_DTE_DDateA value is required if the value in the Coating Present? cell is Y. Enter the value in the following format: YYYY-MM-DD hh:mm:ss
Coating QualityMI_RBDEMEEV_COAT_QUAL_CCharacter (50)

A value is required if the value in the Coating Present? cell is Y.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • NONE
  • POOR
  • MEDIUM
  • HIGH

The list in this field is populated by the 581_Coating_Quality System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Insulation ConditionMI_RBDEMEEV_INSUL_CON_CCharacter (50)

A value is required if the value in the Damage Mechanism cell is 581-Ferritic Component Corrosion Under Insulation.

This cell may only contain one of the following values:

  • Above Average
  • Average
  • Below Average
Piping System ComplexityMI_RBDEMEEV_PIP_SYS_COMPL_CCharacter (50)

A value is required if the value in the Damage Mechanism cell is 581-Ferritic Component Corrosion Under Insulation.

This cell may only contain one of the following values:

  • Above Average
  • Average
  • Below Average
Corrosion Rate Adjustment for bad Design/FabricationMI_581_XDME_ADJST_FR_DSN_FBN_CBooleanEnter True or False.
Soil to Air Interface Present?MI_581_XDME_SL_TO_AR_INE_PRT_LBooleanEnter True or False.
Atmospheric ConditionMI_581_XDME_ATMOSPHERC_CNDTN_CCharacter (50)

A value is required if the value in the Selected External Corrosion Rate cell is Calculated.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • MARINE
  • TEMPERATE
  • DRY
  • SEVERE

The list in this field is populated by the MI_ATMOSPHERIC_CONDITION System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Last Known Inspection DateMI_581DMCHE_LST_KNWN_INN_DTE_DDateEnter a value in the following format: YYYY-MM-DD hh:mm:ss
Last Known ThicknessMI_581DMCHE_LST_KNWN_THCKNSS_NNumericA value is required if you entered a value in the Last Known Inspection Date cell.
Number of A Level InspectionsMI_581DMCHE_NMR_OF_A_LVL_INS_NNumericA value is required.
Number of B Level InspectionsMI_581DMCHE_NMR_OF_B_LVL_INS_NNumericA value is required.
Number of C Level InspectionsMI_581DMCHE_NMR_OF_C_LVL_INS_NNumericA value is required.
Number of D Level InspectionsMI_581DMCHE_NMR_OF_D_LVL_INS_NNumericA value is required.

DME_ExternalCracking Worksheet

In the DME_ExternalCracking worksheet, you can specify the following DMs that you want to create or update:

  • 581-Austenitic Component Cracking Under Insulation
  • 581-Austenitic Component Atmospheric Cracking

These DMs belong to the RBI 581 External Cracking Damage Evaluation methodology. These records will be linked to an RBI 581 Risk Analysis. You can specify these DMs only if the component type is not Tank Bottom (i.e., the value in the Component Family column in the RBI_Component worksheet is not MI_CCRBICTB).

Field Caption

Field ID

Data Type (Length)

Comments

Asset ID

MI_EQUIP000_EQUIP_ID_C

Character (255)

Values in this column must match values entered in the Assets worksheet. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column).

Asset CMMS System

MI_EQUIP000_SAP_SYSTEM_C

Character (255)

Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column).

Equipment Technical Number

MI_EQUIP000_EQUIP_TECH_NBR_C

Character (255)

Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column).

Component

MI_RBICOMPO_COMPO_C

Character (250)Values in this column must match values entered in the RBI_Component worksheet, if they exist. Multiple DMs can be linked to the same component (i.e., rows may have the same value in this column).

Component Type

MI_RBICOMPO_COMPO_TYPE_C

Character (60)

Values in this column must match values that you entered in the Component Type column on the RBI_Component worksheet for the associated component.

Analysis Unique IDMI_ANALYSIS_IDCharacter (255)Values in this column must match values entered in the RBI_581_Analysis worksheet, if they exist. Multiple DMs can be linked to the same analysis (i.e., rows may have the same value in this column).
Event TypeMI_CRITANAL_ANAL_TYPE_CCharacter (1)This column is not required. The value in this column must correspond to the value entered in the Event Type column on the RBI_581_Analysis worksheet.
Sub IDMI_CRITANAL_SUB_ID_CCharacter (50)This column is not required. The value in this column must match the value entered in the Sub ID column in the RBI_581_Analysis worksheet.
Damage MechanismMI_RBDEMEEV_DAM_MECH_CCharacter (50)

In the baseline APM system, this cell may only contain one of the following values, which exist in the list in the Damage Mechanism field in the Potential Degradation Mechanism record:

  • 581-Ferritic Component Atmospheric Corrosion

  • 581-Ferritic Component Corrosion Under Insulation

Number of Highest Effective InspectionsMI_RBDEMEEV_NO_HIGH_EFF_INS_NNumericA value is required, and must be between 0 and 6. If you enter 0 in this column, then the value in the Highest Effective Inspection Level column must be E.
Highest Effective Inspection LevelMI_RBDEMEEV_HIGH_EFF_INSP_CCharacter (25)

A value is required.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDHighest Effective Inspection Level
AHighly Effective
BUsually Effective
CFairly Effective
DPoorly Effective
EIneffective (None)

The list in this field is populated by the MI_581_Inspection_Effectiveness System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Last Known Inspection DateMI_581DMCHE_LST_KNWN_INN_DTE_DDateEnter a value in the following format: YYYY-MM-DD hh:mm:ss
Susceptibility TypeMI_581DMCHE_SUSCEPTBLTY_TYPE_CCharacter (50)

A value is required.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • Estimated
  • Detected
  • Calculated

The list in this field is populated by the MI_581_Cracking_Susceptibility_Types System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Atmospheric ConditionMI_581_XCDME_ATMOS_CONDI_CCharacter (50)

A value is required if the value in the Susceptibility Type cell is Calculated.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • MARINE
  • TEMPERATE
  • DRY
  • SEVERE

The list in this field is populated by the MI_ATMOSPHERIC_CONDITION System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APMM system, via Configuration Manager, refer to the appropriate table.

SusceptibilityMI_581DMCHE_SUSCEPTIBILITY_CCharacter (50)

A value is required if the value in the Susceptibility Type cell is Estimated.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • High
  • Medium
  • Low
  • None

The list in this field is populated by the MI_581_Cracking_Susceptibility System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Coating Present?MI_581DMCHE_COATING_PRESENT_CCharacter (3)

A value is required.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDCoating Present?
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Coating Installation DateMI_581DMCHE_CTNG_INSTLLN_DTE_DDateA value is required if the value in the Coating Present? cell is Y. Enter the value in the following format: YYYY-MM-DD hh:mm:ss
Coating QualityMI_RBDEMEEV_COAT_QUAL_CCharacter (50)

A value is required if the value in the Coating Present? cell is Y.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • NONE
  • POOR
  • MEDIUM
  • HIGH

The list in this field is populated by the 581_Coating_Quality System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Piping System ComplexityMI_RBDEMEEV_PIP_SYS_COMPL_CCharacter (50)

A value is required if the value in the Damage Mechanism cell is 581-Austenitic Component Cracking Under Insulation.

This cell may only contain one of the following values:

  • Above Average
  • Average
  • Below Average
Insulation ConditionMI_RBDEMEEV_INSUL_CON_CCharacter (50)

A value is required if the value in the Damage Mechanism cell is 581-Austenitic Component Cracking Under Insulation.

This cell may only contain one of the following values:

  • Above Average
  • Average
  • Below Average
Chloride Free InsulationMI_581_XCDME_CHL_FREE_INSUL_CCharacter (50)

A value is required if the value in the Damage Mechanism cell is 581-Austenitic Component Cracking Under Insulation.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDCoating Present?
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

DME_Cracking Worksheet

In the DME_Cracking worksheet, you can specify the following DMs that you want to create or update:

  • 581-Amine Cracking
  • 581-Alkaline Carbonate Stress Corrosion Cracking
  • 581-HIC/SOHIC - HF
  • 581-HIC/SOHIC - H2S
  • 581-Caustic Cracking
  • 581-Hydrogen Stress Cracking
  • 581-Other Cracking
  • 581-Sulfide Stress Cracking
  • 581-Chloride Stress Corrosion Cracking
  • 581-Polythionic Acid Cracking

These DMs belong to the RBI 581 Cracking Damage Evaluation methodology. These records will be linked to an RBI 581 Risk Analysis.

Field Caption

Field ID

Data Type (Length)

Comments

Asset ID

MI_EQUIP000_EQUIP_ID_C

Character (255)

Values in this column must match values entered in the Assets worksheet. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column).

Asset CMMS System

MI_EQUIP000_SAP_SYSTEM_C

Character (255)

Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column).

Equipment Technical Number

MI_EQUIP000_EQUIP_TECH_NBR_C

Character (255)

Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column).

Component

MI_RBICOMPO_COMPO_C

Character (250)Values in this column must match values entered in the RBI_Component worksheet, if they exist. Multiple DMs can be linked to the same component (i.e., rows may have the same value in this column).

Component Type

MI_RBICOMPO_COMPO_TYPE_C

Character (60)

Values in this column must match values that you entered in the Component Type column on the RBI_Component worksheet for the associated component.

Analysis Unique IDMI_ANALYSIS_IDCharacter (255)Values in this column must match values entered in the RBI_581_Analysis worksheet, if they exist. Multiple DMs can be linked to the same analysis (i.e., rows may have the same value in this column).
Event TypeMI_CRITANAL_ANAL_TYPE_CCharacter (1)This column is not required. The value in this column must correspond to the value entered in the Event Type column on the RBI_581_Analysis worksheet.
Sub IDMI_CRITANAL_SUB_ID_CCharacter (50)This column is not required. The value in this column must match the value entered in the Sub ID column in the RBI_581_Analysis worksheet.
Damage MechanismMI_RBDEMEEV_DAM_MECH_CCharacter (50)

In the baseline APM system, this cell may only contain one of the following values, which exist in the list in the Damage Mechanism field in the Potential Degradation Mechanism record:

  • 581-Amine Cracking
  • 581-Alkaline Carbonate Stress Corrosion Cracking
  • 581-HIC/SOHIC - HF
  • 581-HIC/SOHIC - H2S
  • 581-Caustic Cracking
  • 581-Hydrogen Stress Cracking
  • 581-Other Cracking
  • 581-Sulfide Stress Cracking
  • 581-Chloride Stress Corrosion Cracking
  • 581-Polythionic Acid Cracking
Number of Highest Effective InspectionsMI_RBDEMEEV_NO_HIGH_EFF_INS_NNumericA value is required, and must be between 0 and 6. If you enter 0 in this column, then the value in the Highest Effective Inspection Level column must be E.
Highest Effective Inspection LevelMI_RBDEMEEV_HIGH_EFF_INSP_CCharacter (25)

A value is required.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDHighest Effective Inspection Level
AHighly Effective
BUsually Effective
CFairly Effective
DPoorly Effective
EIneffective (None)

The list in this field is populated by the MI_581_Inspection_Effectiveness System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Last Known Inspection DateMI_581DMCHE_LST_KNWN_INN_DTE_DDateEnter a value in the following format: YYYY-MM-DD hh:mm:ss
Susceptibility TypeMI_581DMCHE_SUSCEPTBLTY_TYPE_CCharacter (50)

A value is required.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • Estimated
  • Detected
  • Calculated

The list in this field is populated by the MI_581_Cracking_Susceptibility_Types System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

SusceptibilityMI_581DMCHE_SUSCEPTIBILITY_CCharacter (50)

A value is required only if the value in the Susceptibility Type cell is Estimated. If the value in the Susceptibility Type cell is Calculated or Detected, then APM will not consider the value that you enter in this cell.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • High
  • Medium
  • Low
  • None

The list in this field is populated by the MI_581_Cracking_Susceptibility System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Severity Index Adjustment FactorMI_581DMCHE_SVRY_INX_ADT_FCR_NNumeric

A value is required if the value in the Damage Mechanism cell is 581-Other Cracking.

In the baseline APM system, this cell may only contain one of the following values:

  • 1
  • 0.2
  • 0.02

If the family has been customized, the valid values could be different. This cell may only contain a value that exists in the list in the Severity Index Adjustment Factor field for RBI 581 Cracking Damage Evaluation records.

Online Monitoring FlagMI_581DMCHE_ONLNE_MNTRNG_FLG_CCharacter (50)

A value is required if the value in the Damage Mechanism cell is 581-HIC/SOHIC - H2S.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDOnline Monitoring Flag
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Key Process Variable? MI_581DMCHE_KEY_PROCSS_VRBLE_CCharacter (3)

A value is required if the value in the Online Monitoring Flag cell is Y.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDKey Process Variable
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Hydrogen ProbesMI_581DMCHE_HYDROGEN_PROBES_CCharacter (3)

A value is required if the value in the Online Monitoring Flag cell is Y.

 

Steam Out?MI_581CRKEV_STEAM_OUT_CCharacter (50)

A value is required if:

  • The value in the Damage Mechanism cell is 581-Amine Cracking or 581-Caustic Cracking.

    -and-

  • The value in the Susceptibility Type cell is Calculated.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDSteam Out?
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Sulfur Content of SteelMI_581CRKEV_SLFR_CNTT_OF_STL_CCharacter (50)

A value is required if:

  • The value in the Damage Mechanism cell is 581-HIC/SOHIC - H2S.

    -and-

  • The value in the Susceptibility Type cell is Calculated.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • High Sulfur Steel (>0.01% S)
  • Low Sulfur Steel (<=0.01% S)

The list in this field is populated by the MI_581_Sulfur_Content_Of_Steel System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Maximum Brinnell HardnessMI_581CRKEV_MAX_BRIN_HARD_NNumeric

A value is required if:

  • The value in the Damage Mechanism cell is 581-Hydrogen Stress Cracking or 581-Sulfide Stress Cracking.

    -and-

  • The value in the Susceptibility Type cell is Calculated.
Heat Traced?MI_581CRKEV_HEAT_TRACED_CCharacter (50)

A value is required if:

  • The value in the Damage Mechanism cell is 581-Amine Cracking or 581-Caustic Cracking.

    -and-

  • The value in the Susceptibility Type cell is Calculated.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDHeat Traced?
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

H2S Water ContentMI_581DMCHE_H2S_WTR_CONT_NNumeric

A value is required if:

  • The value in the Damage Mechanism cell is 581-HIC/SOHIC - H2S.

    -and-

  • The value in the Susceptibility Type cell is Calculated.
Product FormMI_581CRKEV_PRODUCT_FORM_CCharacter (50)

A value is required if:

  • The value in the Damage Mechanism cell is 581-HIC/SOHIC - H2S.

    -and-

  • The value in the Susceptibility Type cell is Calculated.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • Seamless/Extruded Pipe
  • Rolled Plate

The list in this field is populated by the MI_581_Product_Form System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

HF Present?MI_581CRKEV_HF_PRESENT_CCharacter (50)

A value is required if:

  • The value in the Damage Mechanism cell is 581-HIC/SOHIC - HF or 581-Hydrogen Stress Cracking.

    -and-

  • The value in the Susceptibility Type cell is Calculated.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDHF Present?
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Amine Solution TypeMI_581CRKEV_AMINE_SOLTN_TYPE_CCharacter (50)

A value is required if:

  • The value in the Damage Mechanism cell is 581-Amine Cracking.

    -and-

  • The value in the Susceptibility Type cell is Calculated.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • Fresh
  • Lean
  • Rich

The list in this field is populated by the MI_581_Amine_Solution_Types System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Amine TypeMI_581CRKEV_AMINE_TYPE_CCharacter (50)

A value is required if:

  • The value in the Damage Mechanism cell is 581-Amine Cracking.

    -and-

  • The value in the Susceptibility Type cell is Calculated.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • MEA
  • DIPA
  • DEA
  • Other Amine

The list in this field is populated by the MI_581_Amine_Types System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in yourAPM system, via Configuration Manager, refer to the appropriate table.

CyanidesMI_RBDEMEEV_CYANI_FBoolean

Enter True or False.

Caustic TypeMI_581CRKEV_CAUST_TYPE_CCharacter (50)

A value is required if:

  • The value in the Damage Mechanism cell is 581-Caustic Cracking.

    -and-

  • The value in the Susceptibility Type cell is Calculated.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • Area A
  • Area B
  • Area C

The list in this field is populated by the MI_581_Caustic_Types System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

NaOH Caustic ConcentrationMI_581CRKEV_NH_CSTC_CNCNTRTN_NNumeric

A value is required if:

  • The value in the Damage Mechanism cell is 581-Caustic Cracking.

    -and-

  • The value in the Susceptibility Type cell is Calculated.
CO3 Concentration in Water MI_581CRKEV_CO3_CONC_IN_WTR_NNumeric

A value is required if:

  • The value in the Damage Mechanism cell is 581-Alkaline Carbonate Stress Corrosion Cracking.

    -and-

  • The value in the Susceptibility Type cell is Calculated.
Chloride Concentration Water Process MI_581CRKEV_CH_CNC_OF_PR_WTR_CNumeric

A value is required if:

  • The value in the Damage Mechanism cell is 581-Chloride Stress Corrosion Cracking.

    -and-

  • The value in the Susceptibility Type cell is Calculated.
Oxygen ConcentrationMI_581CRKEV_O2_CONC_NNumericThe value in this column is used to calculate Susceptibility if the Susceptibility Type is Calculated and the Damage Mechanism is 581-Chloride Stress Corrosion Cracking.
Deposits PresentMI_581CRKEV_DEP_PRES_LBooleanEnter True or False.

The value in this column is used to calculate Susceptibility if the Susceptibility Type is Calculated and the Damage Mechanism is 581-Chloride Stress Corrosion Cracking.

Exposure to Oxygen During Operation/DowntimeMI_581CRKEV_EXE_TO_OXN_D_OPE_CCharacter (50)

A value is required if:

  • The value in the Damage Mechanism cell is 581-Polythionic Acid Cracking.

    -and-

  • The value in the Susceptibility Type cell is Calculated.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDExposure to Oxygen During Operation/Downtime
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Exposure to Sulfur During Operation/DowntimeMI_581CRKEV_EXE_TO_SLR_D_OPE_CCharacter (50)

A value is required if:

  • The value in the Damage Mechanism cell is 581-Polythionic Acid Cracking.

    -and-

  • The value in the Susceptibility Type cell is Calculated.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDExposure to Sulfur During Operation/Downtime
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Exposure to Water During Operation/ShutdownMI_581CRKEV_EXE_TO_WTR_D_OPN_CCharacter (50)

A value is required if:

  • The value in the Damage Mechanism cell is 581-Polythionic Acid Cracking.

    -and-

  • The value in the Susceptibility Type cell is Calculated.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDExposure to Water During Operation/Shutdown
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Downtime Protection UsedMI_581CRKEV_DWNTME_PRTCN_USD_CCharacter (50)

A value is required if:

  • The value in the Damage Mechanism cell is 581-Polythionic Acid Cracking.

    -and-

  • The value in the Susceptibility Type cell is Calculated.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDDowntime Protection Used
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Thermal History (Heat Treatment History)MI_581CRKEV_THL_HSY_HT_T_HSY_CCharacter (50)

A value is required if:

  • The value in the Damage Mechanism cell is 581-Polythionic Acid Cracking.

    -and-

  • The value in the Susceptibility Type cell is Calculated.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • Solution Annealed
  • Stabilized Before Welding
  • Stabilized After Welding

The list in this field is populated by the MI_581_Heat_Treatment_History System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

DME_HTHA Worksheet

In the DME_HTHA worksheet, you can specify the 581-High Temperature Hydrogen Attack DM that you want to create or update. This DM, however, is not applicable for a component of type Storage Tank Bottom.

Field Caption

Field ID

Data Type (Length)

Comments

Asset ID

MI_EQUIP000_EQUIP_ID_C

Character (255)

Values in this column must match values entered in the Assets worksheet. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column).

Asset CMMS System

MI_EQUIP000_SAP_SYSTEM_C

Character (255)

Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column).

Equipment Technical Number

MI_EQUIP000_EQUIP_TECH_NBR_C

Character (255)

Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column).

Component

MI_RBICOMPO_COMPO_C

Character (250)

Values in this column must match values entered in the RBI_Component worksheet, if they exist. Multiple DMs can be linked to the same component (i.e., rows may have the same value in this column).

Component Type

MI_RBICOMPO_COMPO_TYPE_C

Character (60)

Values in this column must match values that you entered in the Component Type column on the RBI_Component worksheet for the associated component.

Analysis Unique IDMI_ANALYSIS_IDCharacter (255)Values in this column must match values entered in the RBI_581_Analysis worksheet, if they exist. Multiple DMs can be linked to the same analysis (i.e., rows may have the same value in this column).
Damage MechanismMI_RBDEMEEV_DAM_MECH_CCharacter (50)

Enter 581-High Temperature Hydrogen Attack.

Event TypeMI_CRITANAL_ANAL_TYPE_CCharacter (1)This column is not required. The value in this column must correspond to the value entered in the Event Type column on the RBI_581_Analysis worksheet.
Sub IDMI_CRITANAL_SUB_ID_CCharacter (50)This column is not required. The value in this column must match the value entered in the Sub ID column in the RBI_581_Analysis worksheet.
Is HTHA Damage ObservedMI_581_HTHA_IS_DAMAG_OBS_CCharacter (50)

A value is required.

In the baselineAPM system, this cell may only contain one of the following System Code IDs:

System Code IDIs HTHA Observed
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Is Component ReplacedMI_581_HTHA_IS_COMPO_REPLA_CCharacter (50)

A value is required if the value in the Is HTHA Damage Observed cell is Y.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDIs Component Replaced
YYes
NNo

The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Exposure Hydrogen Partial PressureMI_581_HTHA_HYDRO_PAR_PRESS_NNumeric

A value is required if the value in the Is HTHA Damage Observed cell is N.

Delta TemperatureMI_581_HTHA_DELTA_TEMPE_CCharacter (50)

A value is required if the value in the Is HTHA Damage Observed cell is N.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

  • >=0
  • >= -50 and < 0
  • >= -100 and < -50
  • < -100

The list in this field is populated by the MI_581_HTHA_Delta_Temperature System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

DME_MechanicalFatigue Worksheet

In the DME_MechanicalFatigue worksheet, you can specify the 581-Mechanical Fatigue DM that you want to create or update. This DM, however, is not applicable for a component of type Storage Tank Bottom.
Note: All the field values should be of data type character as these are all System Code Table IDs.

Field Caption

Field ID

Data Type (Length)

Comments

Asset ID

MI_EQUIP000_EQUIP_ID_C

Character (255)

Values in this column must match values entered in the Assets worksheet. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column).

Asset CMMS System

MI_EQUIP000_SAP_SYSTEM_C

Character (255)

Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column).

Equipment Technical Number

MI_EQUIP000_EQUIP_TECH_NBR_C

Character (255)

Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column).

Component

MI_RBICOMPO_COMPO_C

Character (250)

Values in this column must match values entered in the RBI_Component worksheet, if they exist. Multiple DMs can be linked to the same component (i.e., rows may have the same value in this column).

Component Type

MI_RBICOMPO_COMPO_TYPE_C

Character (60)

Values in this column must match values that you entered in the Component Type column on the RBI_Component worksheet for the associated component.

Analysis Unique IDMI_ANALYSIS_IDCharacter (255)Values in this column must match values entered in the RBI_581_Analysis worksheet, if they exist. Multiple DMs can be linked to the same analysis (i.e., rows may have the same value in this column).
Damage MechanismMI_RBDEMEEV_DAM_MECH_CCharacter (50)

Enter 581-High Temperature Hydrogen Attack.

Event TypeMI_CRITANAL_ANAL_TYPE_CCharacter (1)This column is not required. The value in this column must correspond to the value entered in the Event Type column on the RBI_581_Analysis worksheet.
Sub IDMI_CRITANAL_SUB_ID_CCharacter (50)This column is not required. The value in this column must match the value entered in the Sub ID column in the RBI_581_Analysis worksheet.
Previous Failure MI_581MECHFT_PREVIOUS_FAIL_C Character (50)

A value is required.

In the baselineAPM system, this cell may only contain one of the following System Code IDs:
System Code IDPrevious Failure
1No Failures
50One Failures
500Two or more Failures
Visible/Audible ShakingMI_581MECHFT_SHAKING_C Character (50)

A value is required.

In the baselineAPM system, this cell may only contain one of the following System Code IDs:
System Code IDVisible/Audible Shaking
1Minor
50Moderate
500Severe
Shaking FrequencyMI_581MECHFT_SHAKING_DRTN_WKS_C Character (50)

A value is required.

In the baselineAPM system, this cell may only contain one of the following System Code IDs:
System Code IDShaking Frequency
1Shaking less than 2 weeks
0.2Shaking between than 2 and 13 weeks
0.02Shaking between than 13 and 52 weeks
Cyclic LoadingMI_581MECHFT_CYCLIC_LOADING_C Character (50)

A value is required.

In the baselineAPM system, this cell may only contain one of the following System Code IDs:
System Code IDCyclic Loading
50Reciprocating Machinery
25PRV Chatter
10Valve with high pressure drop
1None
Pipe ConditionMI_581MECHFT_PIPE_CONDITION_C Character (50)

A value is required.

In the baselineAPM system, this cell may only contain one of the following System Code IDs:
System Code IDPipe Condition
2Missing or Damaged supports or Broken guessets
1Good Condition
Corrective ActionMI_581MECHFT_CORREC_ACTIN_C Character (50)

A value is required.

In the baselineAPM system, this cell may only contain one of the following System Code IDs:
System Code IDCorrective Action
0.002Modification – Complete Engineering Analysis
0.2Modification based on experience
2No modifications
Branch DiameterMI_581MECHFT_ADJST_FR_BRHDMR_C Character (50)

A value is required.

In the baselineAPM system, this cell may only contain one of the following System Code IDs:
System Code IDBranch Diameter
1All branches less than or equal to 2 NPS
0.02Any branch greater than 2 NPS
Joint Type or Branch DesignMI_581MECHFT_ADT_FR_JNTT_DSN_CCharacter (50)

A value is required.

In the baselineAPM system, this cell may only contain one of the following System Code IDs:
System Code IDJoint Type or Branch Design
2Threaded
1Saddle in fittings
0.2Piping tee
0.02Sweepolets
1,9999Socketweld
2.000001Saddle on
0.2000001Weldolets
Pipe ComplexityMI_581MECHFT_ADJST_FR_PPECMY_C Character (50)

A value is required.

In the baselineAPM system, this cell may only contain one of the following System Code IDs:
System Code IDPipe Complexity
0.5 0 to 5 total pipe fittings
1 6 to 10 total pipe fittings
2 Greater than 10 total pipe fittings

DME_BrittleFracture Worksheet

In the DME_BrittleFracture worksheet, you can specify the following DMs that you want to create or update:

  • 581-Sigma Phase Embrittlement
  • 581-885F Embrittlement
  • 581-Brittle Fracture
  • 581-Low Alloy Steel Embrittlement

Field Caption

Field ID

Data Type (Length)

Comments

Asset ID

MI_EQUIP000_EQUIP_ID_C

Character (255)

Values in this column must match values entered in the Assets worksheet. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column).

Asset CMMS System

MI_EQUIP000_SAP_SYSTEM_C

Character (255)

Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column).

Equipment Technical Number

MI_EQUIP000_EQUIP_TECH_NBR_C

Character (255)

Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column).

Component

MI_RBICOMPO_COMPO_C

Character (250)Values in this column must match values entered in the RBI_Component worksheet, if they exist. Multiple DMs can be linked to the same component (i.e., rows may have the same value in this column).

Component Type

MI_RBICOMPO_COMPO_TYPE_C

Character (60)

Values in this column must match values that you entered in the Component Type column on the RBI_Component worksheet for the associated component.

Analysis Unique IDMI_ANALYSIS_IDCharacter (255)Values in this column must match values entered in the RBI_581_Analysis worksheet, if they exist. Multiple DMs can be linked to the same analysis (i.e., rows may have the same value in this column).
Event TypeMI_CRITANAL_ANAL_TYPE_CCharacter (1)This column is not required. The value in this column must correspond to the value entered in the Event Type column on the RBI_581_Analysis worksheet.
Sub IDMI_CRITANAL_SUB_ID_CCharacter (50)This column is not required. The value in this column must match the value entered in the Sub ID column in the RBI_581_Analysis worksheet.
Damage MechanismMI_RBDEMEEV_DAM_MECH_CCharacter (50)

In the baseline APM system, this cell may only contain one of the following values, which exist in the list in the Damage Mechanism field in the Potential Degradation Mechanism record:

  • 581-Sigma Phase Embrittlement
  • 581-885F Embrittlement
  • 581-Brittle Fracture
  • 581-Low Alloy Steel Embrittlement
Material Exemption CurveMI_581BRFRAC_MTRL_EXMPTNCRVE_NCharacter (50)

A value is required if the value in the Damage Mechanism cell is 581-Brittle Fracture or 581-Low Alloy Steel Embrittlement.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDMaterial Exemption Curve
ATemperature Exemption A Curve
BTemperature Exemption B Curve
CTemperature Exemption C Curve
DTemperature Exemption D Curve

The list in this field is populated by the MI_581_Material_Temperature_Exemption_Curves System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

Minimum Allowable TemperatureMI_581BRFRAC_MNMM_ALLWBLETME_NNumeric

A value is required if the Damage Mechanism cell contains one of the following values:

  • 581-Sigma Phase Embrittlement
  • 581-885F Embrittlement
  • 581-Low Alloy Steel Embrittlement
Minimum Design Metal Temperature (MDMT)MI_581BRFRAC_MNM_DSN_MTL_MDT_NNumeric

A value is required if the Damage Mechanism cell contains one of the following values:

  • 581-885F Embrittlement
  • 581-Low Alloy Steel Embrittlement
Critical Exposure Temperature(CET)MI_581BRFRAC_CRTCLEXPSRE_TMT_NNumeric

A value is required if the value in the Damage Mechanism cell is 581-Brittle Fracture.

Is CET at the MAWP >= -29°CMI_581BRIFRAC_IS_CT_PVPCRT_LBooleanEnter True or False.
Is Cyclic service Design RequirementMI_581BRIFRAC_IS_CYC_SREFRQT_LBooleanEnter True or False.
Is Asset Or Circuit Subject to EVN CrackingMI_581BRIFRAC_IS_EQT_CRCRG_LBooleanEnter True or False.
Is Asset Or Circuit Subject to Shock ChillingMI_581BRIFRAC_IS_EQT_CR_SCHG_LBooleanEnter True or False.
Is Fabricated From P-1 and P-3 SteelsMI_581BRIFRAC_IS_FBD_FRMP65F_LBooleanEnter True or False.
Is Nominal Operating Conditions ChangedMI_581BRIFRAC_IS_NML_OPGCCHD_LBooleanEnter True or False.
Is Nominal Uncorroded Thickness < 50.8 mm (2 inch)MI_581BRIFRAC_NML_UNDTHS_INH_LBooleanEnter True or False.
Is Satisfied All Requirements For FabricationMI_581BRIFRAC_IS_STD_ALLRFRN_LBooleanEnter True or False.
Fracture Appearance Transition Temperature(FATT)MI_581BRFRAC_FRCEAPE_TRN_TME_NNumericA value is required if the value in the Damage Mechanism cell is 581-Low Alloy Steel Embrittlement.
Sigma PercentageMI_581BRIFRAC_SIGMA_AMOUNT_NNumeric

A value is required if the value in the Damage Mechanism cell is 581-Sigma Phase Embrittlement.

In the baseline APM system, this cell may only contain one of the following System Code IDs:

System Code IDSigma Percentage
11
22
33
44
55
66
77
88
99
10>=10

The list in this field is populated by the MI_581_Sigma_Percentage System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table.

About the Risk Based Inspection (RBI) 581 Data Loader Load Verification

About This Task

Following a data load, you should perform the following steps in APM to confirm the integrity and accuracy of the data imported from the data loader workbook.

Procedure

  1. Access the details of the import job. These details will indicate if any errors, minor or otherwise, were encountered during the import job. The log may help account for any records that are unexpectedly absent after the data load.
  2. In Risk Based Inspection or Record Manager, access the assets specified in the data loader workbook, and then verify that the expected components are present or updated, and that any associated records that you expected to be created are also present in the database.

    You can enter the following query in the SQL workspace of the Query page to review a list of components created after a specified date:

    SELECT [MI_CCRBICOM].LAST_UPDT_DT "LAST_UPDT_DT", [MI_CCRBICOM].[MI_RBICOMPO_COMPO_C] "Component", [MI_CCRBICOM].[MI_RBICOMPO_COMPO_TYPE_C] "Component Type", [MI_CCRBICOM].[MI_RBICOMPO_EQUIP_C] "Asset", [MI_CCRBICOM].ENTY_ID "ENTY_ID" FROM [MI_CCRBICOM] WHERE [MI_CCRBICOM].LAST_UPDT_DT >= CONVERT(VARCHAR(255), (? :d :caption='Enter a Date'), 110) ORDER BY [MI_CCRBICOM].LAST_UPDT_DT Desc,[MI_CCRBICOM].[MI_RBICOMPO_EQUIP_C] Asc

    You can enter the following query in the Oracle or Postgres workspace of the Query page to review a list of components created after a specified date:

    SELECT [MI_CCRBICOM].LAST_UPDT_DT "LAST_UPDT_DT", [MI_CCRBICOM].[MI_RBICOMPO_COMPO_C] "Component", [MI_CCRBICOM].[MI_RBICOMPO_COMPO_TYPE_C] "Component Type", [MI_CCRBICOM].[MI_RBICOMPO_EQUIP_C] "Asset", [MI_CCRBICOM].ENTY_ID "ENTY_ID" FROM [MI_CCRBICOM] WHERE [MI_CCRBICOM].LAST_UPDT_DT >= to_date(to_char((? :d :caption='Enter a Date'),'mm/dd/yyyy'),'mm/dd/yyyy') ORDER BY [MI_CCRBICOM].LAST_UPDT_DT Desc,[MI_CCRBICOM].[MI_RBICOMPO_EQUIP_C] Asc
  3. When prompted, enter the date on which the data load was performed.