RBI 581 Data Loader
About RBI Data Loaders
APM, through the Risk Based Inspection module, provides the functionality to carry out an RBI Analysis on various types of RBI components to calculate corrosion rate, and the probability and consequence of failure, and then develop intelligent strategies. Using the RBI Data Loaders, you can generate all components for a Process Unit along with the associated analyses.
About the Risk Based Inspection (RBI) 581 Data Loader
Using the Risk Based Inspection (RBI) 581 Data Loader, you can implement Risk Based Inspection when you have RBI data in a legacy system, which is not supported by APM. To import data using the Risk Based Inspection (RBI) 581 Data Loader, APM provides an Excel template, RBI_581_Data_Loader.xlsx, which supports baseline Risk Based Inspection APM. You must export your legacy system so that the data can be used to populate the template. The data from the template will then be imported into APM using the Risk Based Inspection (RBI) 581 Data Loader.
The data loader workbook can be used in the following scenarios:
- Create or update components
- Create or update analyses
- Loading components and risk analysis data into APM so that you can retain visibility into the analysis details and calculations, and generate recommendations.
- Calculate risk, probability and consequence of failure, and then utilize the Inspection Planning feature to mitigate the risk by the plan date.
After importing the data, the Risk Based Inspection (RBI) 581 Data Loader creates the following records in APM:
- Criticality Calculator RBI Component
- RBI 581 Risk Analysis
- RBI Consequence Evaluation
- RBI 581 Thinning and Lining Evaluation
- RBI 581 External Damage Evaluation
- RBI 581 External Cracking Damage Evaluation
- RBI 581 Cracking Damage Evaluation
- RBI 581 HTHA Damage Evaluation
- RBI 581 Mechanical Fatigue Damage Evaluation
- RBI 581 Brittle Fracture Damage Evaluation
The data on the (Picklist) worksheet is not loaded when you load data using the Risk Based Inspection (RBI) 581 Data Loader.
About the Risk Based Inspection (RBI) 581 Data Loader Requirements
Before you use the Risk Based Inspection (RBI) 581 Data Loader, you must complete the following steps:
- Ensure that the RBI 581 module is deployed.
-
Ensure that the following data is present:
- Site Reference
- Equipment Taxonomy
- Equipment and Functional Location Families
- RBI Data Mapping
- Units of Measure Conversion Sets
-
Stress Tables (APM provides Stress Tables for Pressure Vessels and Tanks. If you want to use values from these Stress Tables with the data load, you must ensure that the records are imported into your database prior to performing the data load. APM does not provide Piping Stress Tables).
- Representative Fluids
- If you have added custom fields to Risk Mapping families (e.g., RBI Risk Matrix Mapping, Risk Analysis Mapping), you must ensure that mappings exist for those fields, or data may not be populated as expected after the data load. This is because the Risk Based Inspection (RBI) 581 Data Loader relies on Risk Mapping families to ensure that fields on RBI 581 Risk Analysis and related records are correctly populated with data, and that resulting risk values can be mapped to the Default Risk Matrix.
- The Security User performing the data load operation must be associated with either the MI Data Loader User or MI Data Loader Admin Security Role, and must also be associated with the MI RBI Analyst Security Group or a Security Role that is associated with this Security Group.
- The data loader workbook contains sample data in each column. It is only for your reference. You must remove this data before using the data loader workbook.
About the Risk Based Inspection (RBI) 581 Data Loader Data Model
This topic has been intentionally excluded from the APM product documentation website. This topic is available to you via the product documentation that is provided within the APM system.
About the Risk Based Inspection (RBI) 581 Data Loader General Loading Strategy
The imported data must load in a specific sequence in order to successfully populate fields, to create records, and to link them to the predecessor and/or successor records.
Best Practices
When importing data using the Risk Based Inspection (RBI) 581 Data Loader, you must use the following best practices:
- ID fields must not include special characters or spaces.
- Columns (including columns representing custom fields) in the worksheets should be formatted as Text.
- Import a maximum of 500 assets in each data load. The maximum number of records that you can load per asset using the data loader is specified in the Best Practices for Loading a Single Asset topic.
- Do not try to create and update a component in the same data loader workbook.
- Ensure that you enter values in cells that correspond to fields required to calculate an analysis. Otherwise, warnings will be issued in the log for the analysis and related records with invalid data.
-
When a field whose value is required based on the value in another field is blank, a warning is logged in the log file of the import job.
- You must consider the rules described in the Workbook Layout and Use section of this document while using the Risk Based Inspection (RBI) 581 Data Loader.
- If you have entered data related to an analysis or a DME, then you must always enter data of the associated component in the RBI_Component worksheet, even if the corresponding Criticality Calculator RBI Component record exists in the APM database.
- You must enter a valid value in the following cells in the RBI_Component worksheet; Otherwise, the row that corresponds to that component is skipped:
- Component ID
- Component Type
- Process FluidNote: If the value is left blank, a valid value must be provided for each associated RBI 581 Risk Analyses.
- GFF Component TypeNote: If the value is left blank, a valid value must be provided for each associated RBI 581 Risk Analyses.
-
When you use the data loader to create an analysis and a cell that requires a Boolean value is blank, the corresponding field in APM is updated with the value False. When you use the data loader to update an analysis and a cell that requires a Boolean value is blank, the corresponding field in APM is not updated. Therefore, to avoid ambiguity, we recommend that you enter the valueTrue or False in the cell and not leave it blank.
- If you want to override the default values that you have specified in the RBI 581 Admin Options workspace, you can include those values in the Risk Based Inspection (RBI) 581 Data Loader. For example, if the value for the Atmospheric Condition field for an RBI 581 External Damage Evaluation record is set to Temperate in the RBI 581 Admin Options workspace. You can override this value by entering a different value in the Atmospheric Condition cell in the DME_ExternalDamage worksheet.
- If you want to override values that are populated from the associated component, you can include those values in the Risk Based Inspection (RBI) 581 Data Loader. For example, the value for the Operating Temperature field in an RBI 581 Risk Analysis is populated from the corresponding field in the associated RBI Component. If you want to override this value for the analysis, you must include a column for Operating Temperature in the RBI_581_Analysis worksheet in the data loader workbook, and enter the value in that cell.
-
In addition to the fields included in the Risk Based Inspection (RBI) 581 Data Loader, if you want to add values for more fields for a record, you can add columns for those fields in the appropriate worksheet.
Note: The fields that you want to add to the data loader workbook must already exist in the corresponding family. If not, you must add the fields to the family via Configuration Manager. - You should not add columns that correspond to fields in the Outputs and Intermediate Outputs sections of a datasheet; Otherwise, the calculations might not be correct.
- You should not add a column that corresponds to the Use Combined Confidence and Use Related Inspection fields to any of the following worksheets:
-
DME_Thinning
- DME_ExternalCracking
-
DME_Cracking
The Use Combined Confidence field is part of the integration of the Risk Based Inspection and Inspection Management modules. A value should only be set in APM.
-
Load Sequence
The data is loaded in the following sequence in order to create all necessary relationships between records:
-
The Assets worksheet is processed. The Data Loader searches for the asset that corresponds to the Asset ID, Asset CMMS System, Equipment Technical Number (only for an Equipment asset) and Asset Family information that you provide in the Assets worksheet.
If an asset specified on the worksheet does not exist, it will be skipped, as well as all entries in the subsequent worksheets corresponding to that asset.
-
The RBI_Component worksheet is processed. The Data Loader searches for the RBI Component based on the asset data and the values in the Component and Component Type cells.
If a component exists in the APM database, it will be updated. If not, a new component will be created, and linked to the asset.
-
The RBI 581 Analysis worksheet is processed. For each row based on the cells specified in steps 1 and 2, a new analysis is created and linked to that component. You cannot update an analysis using the data loader workbook. The value in the Analysis Unique ID cell is not stored but will be used to identify all the Degradation Mechanism Evaluations and Consequence Evaluations specified on the subsequent worksheets that should be linked to the analysis.
If there is invalid data for calculating an analysis, the analysis will still be loaded, but warnings will be issued in the log for all fields with incorrect values.
- The RBI 581 Consequence worksheet is processed. For each row based on the cells specified in steps 1 to 3, a Consequence Evaluation is created, and linked to the specified analysis.
-
The worksheets representing Degradation Mechanism Evaluations are processed. For each row based on the cells specified in steps 1 to 3, a Degradation Mechanism Evaluation is created, and linked to the specified analysis. Additionally, for each Damage Mechanism, a corresponding Potential Degradation Mechanism is created, and linked to the component, unless a Potential Degradation Mechanism of the same type is already linked to the same component.
When the Degradation Mechanism Evaluations are processed, if you have not included a Degradation Mechanism in the worksheet that corresponds to an existing Potential Degradation Mechanism on the component, that Potential Degradation Mechanism will be unlinked.
Data that you specify in the cells on each worksheet will be included in the records. Additionally, fields in the records will be populated with data based on your RBI Data Mapping. For example, an RBI 581 Risk Analysis will be populated with data from the RBI Component to which it is linked the same way it happens if you create the same records in APM.
Best Practices for Loading a Single Asset
For optimal performance, we recommend that you load a maximum of 14 Components with three DMEs each or 9 Components with seven DMEs. To avoid performance degradation of the data loader, you must maintain the total number of records within this limit. If you want to load more number of DMEs, you must reduce the maximum number of components.
The following tables provide illustrations of the maximum number of records that you can load per Component or Analysis, as applicable. It also provides the maximum total number of records that you can load per Asset.
Record Name | An example of the maximum number of records you can load per Asset/Component/Analysis | An example of the total number of records you can load per Asset |
---|---|---|
RBI Component | 9 per Asset | 9 |
RBI 581 Risk Analysis | 1 per Component | 9 |
RBI 581 Consequence Evaluation | 1 per Analysis | 9 |
Internal DME | 1 per Analysis | 9 |
External DME | 1 per Analysis | 9 |
Cracking DME | 1 per Analysis | 9 |
Lining DME | 1 per Analysis | 9 |
External Cracking DME | 1 per Analysis | 9 |
HTHA DME | 1 per Analysis | 9 |
Brittle Fracture DME | 1 per Analysis | 9 |
Total number of records | 90 |
About the Risk Based Inspection (RBI) 581 Data Loader Workbook Layout and Use
To import data using the Risk Based Inspection (RBI) 581 Data Loader, APM provides an Excel workbook, Risk Based Inspection (RBI) 581.xlsx, which supports baseline Risk Based Inspection in APM. This workbook must be used to perform the data load. You can modify the Excel workbook to include custom fields used by your organization.
Worksheet | Description |
---|---|
Assets | This worksheet is used to specify existing Asset records to which components will be linked. |
RBI_Components | This worksheet is used to specify the following types of RBI Component records that will be updated or created and linked to assets.
|
RBI_581_Analysis | This worksheet is used to define RBI 581 Analysis records that will be linked to components. You cannot update an RBI 581 Risk Analysis using the data loader workbook. |
RBI_581_Consequence | This worksheet is used to define RBI 581 Consequence Evaluation records that will be linked to analyses. Each analysis can be linked to only one RBI 581 Consequence Evaluation. |
DME_Lining | This worksheet is used to specify the 581-Internal Component Lining Damage DMs (which are or will be represented by the RBI 581 Thinning and Lining Evaluation records) that you want to create or update. These records will be linked to an RBI 581 Risk Analysis. You can specify these DMs only if the value in the Lining Present column is True in the RBI_Component worksheet for the associated component. |
DME_AST |
This worksheet is used to specify the 581-Atmospheric Tank Bottom Corrosion DMs (which are or will be represented by the RBI 581 Thinning and Lining Evaluation records) that you want to create or update. These records will be linked to an RBI 581 Risk Analysis. You can specify these DMs only if:
|
DME_Thinning | This worksheet is used to specify the following DMs that you want to create or update:
These DMs belong to the RBI 581 Thinning and Lining Evaluation methodology. These records will be linked to an RBI 581 Risk Analysis. |
DME_ExternalDamage |
This worksheet is used to define the following DMs that you want to create or update:
These DMs belong to the RBI 581 External Damage Evaluation methodology. These records will be linked to an RBI 581 Risk Analysis. You can specify these DMs only if the component type is not Tank Bottom (i.e., the value in the Component Family column in the RBI_Component worksheet is not MI_CCRBICTB). |
DME_ExternalCracking |
This worksheet is used to define the following DMs that you want to create or update:
These DMs belong to the RBI 581 External Cracking Damage Evaluation methodology. These records will be linked to an RBI 581 Risk Analysis. You can specify these DMs only if the component type is not Tank Bottom (i.e., the value in the Component Family column in the RBI_Component worksheet is not MI_CCRBICTB). |
DME_Cracking |
This worksheet is used to specify the following DMs that you want to create or update:
These DMs belong to the RBI 581 Cracking Damage Evaluation methodology. These records will be linked to an RBI 581 Risk Analysis. |
DME_HTHA | This worksheet is used to specify the 581-High Temperature Hydrogen Attack DMs (which are or will be represented by the RBI 581 HTHA Damage Evaluation records) that you want to create or update. These records will be linked to an RBI 581 Risk Analysis. You can specify these DMs only if the component type is not Tank Bottom (i.e., the value in the Component Family column in the RBI_Component worksheet is not MI_CCRBICTB). |
DME_MechanicalFatigue | This worksheet is used to specify the 581- Mechanical Fatigues DMs (which are or will be represented by the RBI 581 Mechanical Fatigue Damage Evaluation records) that you want to create or update. These records will be linked to an RBI 581 Risk Analysis. You can specify these DMs only if the component type is not Tank Bottom (i.e., the value in the Component Family column in the RBI_Component worksheet is not MI_CCRBICTB). |
DME_BrittleFracture |
This worksheet is used to specify the following DMs (which are or will be represented by the RBI 581 Brittle Fracture Damage Evaluation records) that you want to create or update.
These records will be linked to an RBI 581 Risk Analysis. You can specify these DMs only if the component type is not Tank Bottom (i.e., the value in the Component Family column in the RBI_Component worksheet is not MI_CCRBICTB). |
(PickList) |
This worksheet contains a list of valid values that you can enter in each column (as applicable) in the aforementioned worksheets. When you load data using the data loader, the data on this worksheet is not loaded. The values in the some of the columns are filtered based on the values in other fields. For example, the values in the following columns are filtered based on the values in the Stress Lookup Table column:
Also, if you select a value in the BM Code column, the values in the BM Year, BM Spec, and BM Grade columns are filtered accordingly. |
Color Coding
Certain columns on the worksheets have different functions and requirements. To illustrate this, certain columns are color-coded. The following table lists the colors and what they represent.
Color |
Description |
Comments |
---|---|---|
Grey |
Lookup Fields |
Indicates columns that contain values that are used by the Risk Based Inspection (RBI) 581 Data Loader to look up and create records. If these columns are removed from the worksheets, the data load will fail. While the worksheets require that these columns be present, values are not necessarily required in these columns. |
Red |
Fields Required for Calculation |
Indicates columns that contain values that are required to perform calculations in Risk Based Inspection. Some cells only require values in certain cases. Such cases are found in parentheses in the first row of each worksheet. |
Blue |
Recommended Fields |
Indicates columns that, according to APM Best Practice for Risk Based Inspection, should contain values. |
Green |
Custom Fields |
Indicates columns where you can specify custom fields. |
Limitations
The Risk Based Inspection (RBI) 581 Data Loader has the following limitations:
- You must use the data loader workbook. If you modify the format of the values in columns in any of the worksheets, you will not be able to import data.
- Components of the Heat Exchanger - Bundle type are not supported as part of the baseline APM, but you can enter data related to the component.
- The values that you enter in the data loader workbook are case-sensitive.
- You cannot import data related to a custom DME using the Risk Based Inspection (RBI) 581 Data Loader. You must import only those DMEs that are included in the data loader workbook.
-
If you reimport data, the records that have been created by the Data Loader will be updated. While reimporting data, if you remove the data for a field in the data loader workbook, the value for the corresponding field in APM will not be updated.
- You cannot create Inventory Group Configuration records, or link a Component to an inventory group using the data loader workbook.
- When you use the data loader to create an RBI Analysis, if the value provided for the field on the Analysis, Consequence, or Degradation Mechanism Evaluation sheets is empty, the field will be skipped and the default value or the value mapped from the RBI Component will remain.
-
When you use the data loader to update an RBI Component or RBI 581 Analysis and the associated Consequence Evaluation, Damage Mechanisms, and Damage Mechanism Evaluations:
- If a cell contains data, the value in the corresponding field will be updated in the database.
- If a cell is blank, the value in the corresponding field will not be updated with a blank value in the database. The value that previously existed in the field is retained.
- You cannot delete the Consequence Evaluation and the Degradation Mechanism Evaluations associated with an RBI Analysis using the data loader.
- You can set the Event Type column to W and update an existing What-If Analysis using the data loader; however, you cannot create a new What-If Analysis. If there are more than one What-If Analyses linked to a component, you must enter a unique value in the Sub ID column.
- The RBI 581 HE Bundle Damage Evaluation is not supported in Data Loader.
Assets Worksheet
In the Assets worksheet, you will specify assets to which you want to link components. The columns that appear on this worksheet also appear on every subsequent worksheet, and are used to identify the records that will be linked, directly or indirectly, to the assets. The combination of values in the three columns on this worksheet must be unique.
Field Caption |
Field ID |
Data Type (Length) |
Comments |
---|---|---|---|
Asset ID |
MI_EQUIP000_EQUIP_ID_C |
Character (255) |
This column requires at least one cell to have a value. For a Functional Location asset, the field MI_FNCLOC00_FNC_LOC_C must be used. |
Asset CMMS System |
MI_EQUIP000_SAP_SYSTEM_C |
Character (255) |
If the Asset record has a value in the CMMS System field, enter that value in this column. For a Functional Location asset the field MI_FNCLOC00_SAP_SYSTEM_C must be used. |
Asset Family |
ASSET_FAMILY_ID |
Character (255) | This column is required when loading Functional Location assets. If no value is provided, the asset is considered as an Equipment asset. Note: The following values are the valid values:
|
Equipment Technical Number |
MI_EQUIP000_EQUIP_TECH_NBR_C |
Character (255) |
If you are required to enter a value for the CMMS System cell for an equipment asset, and the Equipment has a value in the Equipment Technical Number field, enter that value in this column. If there is no value in the CMMS System field, this column can be blank, even if the Equipment record contains a value for the Equipment Technical Number field. Note: This field must be left blank for a Functional Location asset.
|
RBI_Component Worksheet
In the RBI_Component worksheet, you will specify the components (which are or will be represented by RBI Component records) that you want to create or update.
Field Caption |
Field ID |
Data Type (Length) |
Comments | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Asset ID |
MI_EQUIP000_EQUIP_ID_C |
Character (255) |
Values in this column must match values entered in the Assets worksheet. Multiple components can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Asset CMMS System |
MI_EQUIP000_SAP_SYSTEM_C |
Character (255) |
Values in this column must match values entered in the Assets worksheet, if they exist. Multiple components can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Equipment Technical Number |
MI_EQUIP000_EQUIP_TECH_NBR_C |
Character (255) |
Values in this column must match values entered in the Assets worksheet, if they exist. Multiple components can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Component |
MI_RBICOMPO_COMPO_C | Character (250) | A value is required and must be unique. This value identifies the component. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Component Type |
MI_RBICOMPO_COMPO_TYPE_C | Character (60) | A value is required. This cell may only contain one of the following values, which exist in the list in the Component Type field for RBI Component records:
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Component Family |
FAMILY_ID | Character (50) |
A value is required. This cell may only contain one of the following values:
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Component Description |
MI_RBICOMPO_COMPO_DESCR_C | Character (255) | None | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Component Start Date |
MI_RBICOMPO_COMP_STRT_DATE_DT | Date | A value is required. Enter the value in the following format: YYYY-MM-DD hh:mm:ss | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Circuit From |
MI_CCRBICPI_CIRCU_FROM_C | Character (250) | This value is applicable only if the component type is piping (i.e., the value in the Component Family cell is MI_CCRBICPI). | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Circuit To |
MI_CCRBICPI_CIRCU_TO_C | Character (250) | This value is applicable only if the component type is piping (i.e., the value in the Component Family cell is MI_CCRBICPI). | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Component Comments |
MI_RBICOMPO_COMPO_COMME_TX | Text | None | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Operating Pressure |
MI_RBICOMPO_OPERA_PRESS_N | Numeric |
A value is required. The value in this cell is copied to the Operating Pressure field of the associated RBI Analysis. The value in this cell is compared with the value in the Design Pressure cell for the analysis to be created. The value in this cell must be greater than or equal to zero, and less than or equal to the value in the Design Pressure cell. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Operating Temperature |
MI_RBICOMPO_OPERA_TEMPE_N | Numeric |
A value is required. The value in this cell is copied to the Operating Temperature field of the associated RBI Analysis. The value in this cell is compared with the value in the Design Temperature cell for the analysis to be created. If the value in the Design Temperature cell is greater than or equal to zero, the value in this cell must be less than or equal to the value in the Design Temperature cell. If the value in the Design Temperature cell is less than zero, the analysis can be created with any value in this cell. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Foundation Type |
MI_CCRBICTB_FOUND_TYPE_C | Character (50) |
A value is required if the value in the Component Type cell is Storage Tank Bottom. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the FOUNDATION TYPES System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Initial Fluid Phase |
MI_RBICOMPO_INIT_FLU_PHASE_C | Character (20) |
A value is required. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the FLUID TYPES System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Process Fluid |
MI_RBICOMPO_PROCE_FLUID_C | Character (50) |
The field is required. If the value is left blank, a valid value must be provided on the related child analysis records. This cell may only contain a value that exists in the list in the Process Fluid field for RBI Component records. If you enter a value that is not valid for RBI 581, the Data Loader will skip that row. If the value in the Component Type is Storage Tank Bottom, then this cell may only contain a fluid with a Dynamic Viscosity greater than 0. In the baseline APM, the following fluids have a valid Dynamic Viscosity and are supported by the Storage Tank Bottom:
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Toxic Mixture |
MI_RBICOMPO_TOXIC_MIX_F | Boolean |
Enter True or False. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Toxic Fluid |
MI_RBICOMPO_TOXIC_MODEL_C | Character (50) |
A value is required if the value in the Toxic Mixture cell is True. This cell may only contain a value that exists in the list in the Toxic Fluid field for RBI Component records. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Percent Toxic |
MI_RBICOMPO_PERCE_TOXIC_N | Numeric | A value is required if the value in the Toxic Mixture cell is True. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Inventory |
MI_RBICOMPO_INVEN_N | Numeric | A value is required if component type is not Tank Bottom (i.e., the value in the Component Family cell is not MI_CCRBICTB). | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Inventory Group |
MI_RBICOMPO_INVEN_GROUP_C | Character (50) |
You cannot use this column to link the Component to an inventory group. You can link a component to an inventory group only by accessing the MI Admin Preferences page in APM. If the Component is already linked to an inventory group, you can override the value in the Inventory Group field by entering a value in this column. However, the calculated value in the Inventory Group Mass field remains as is. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Design Pressure |
MI_RBICOMPO_DESIG_PRESS_N | Numeric |
A value is required if the component is linked to the following Potential Degradation Mechanisms (PDMs):
The value in this cell is copied to the Design Pressure field of the associated RBI Analysis. The value in this cell is compared with the value in the Operating Pressure cell for the analysis to be created. The value in this cell must be greater than or equal to zero, and greater than or equal to the value in the Operating Pressure cell. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Design Temperature |
MI_RBICOMPO_DESIG_TEMPE_N | Numeric |
A value is required if the component is linked to a PDM that belongs to the following DMEs:
The value in this cell is copied to the Design Temperature field of the associated RBI Analysis. The value in this cell is compared with the value in the Operating Temperature cell for the analysis to be created. If the value in this cell is greater than or equal to zero, the value in the Operating Temperature cell must be less than or equal to the value in this field. If the value in this cell is less than zero, the analysis is created with any value in the Operating Temperature cell. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Diameter |
MI_RBICOMPO_DIAME_INNER_N | Numeric | A value is required. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Length |
MI_RBICOMPO_LENGT_N | Numeric |
A value is required if you want to calculate inventory. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fill Height | MI_CCRBICTB_FILL_HEIGH_N | Numeric |
A value is required if the value in the Component Type cell is Storage Tank Bottom or Storage Tank. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Nominal Thickness |
MI_RBICOMPO_NOMIN_THICK_N | Numeric |
A value is required if the component is linked to an analysis that is linked to the following damage mechanisms (DMs):
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Stress Lookup Table |
MI_RBICOMPO_STRESS_TABLE_C | Character (50) |
A value is required if the component is linked to an analysis that is linked to the following damage mechanisms (DMs):
In the baseline APM system, this cell may only contain one of the following values:
If the family has been customized, the valid values could be different. This cell may only contain a value that exists in the list in the Stress Lookup Table field for RBI Component records. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
BM CODE |
MI_RBICOMPO_BM_CODE_C | Character (30) |
A value is required if the component is linked to an analysis that is linked to the following damage mechanisms (DMs):
Refer to the (Picklist) worksheet in the excel workbook for valid values that you can enter in this cell. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
BM YEAR |
MI_RBICOMPO_BM_YEAR_C | Character (50) |
A value is required if the component is linked to an analysis that is linked to the following damage mechanisms (DMs):
Refer to the (Picklist) worksheet in the excel workbook for valid values that you can enter in this cell. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
BM SPEC |
MI_RBICOMPO_BM_SPEC_C | Character (50) |
A value is required if the component is linked to an analysis that is linked to the following damage mechanisms (DMs):
Refer to the (Picklist) worksheet in the excel workbook for valid values that you can enter in this cell. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
BM GRADE |
MI_RBICOMPO_BM_GRADE_C | Character (50) |
A value is required if the component is linked to an analysis that is linked to the following damage mechanisms (DMs):
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Weld Joint Effy |
MI_RBICOMPO_WELD_JOINT_EFFY_N | Numeric |
A value is required if the component is linked to a PDM that belongs to the following DMEs:
In the baseline APM, this cell may only contain one of the following values:
If the family has been customized, the valid values could be different. This cell may only contain a value that exists in the list in the Weld Joint Efficiency field for RBI Component records. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Insulated? |
MI_RBICOMPO_INSUL_F | Boolean |
Enter True or False. The value in this cell must be True if the an analysis in the component is linked to one of the following DMs:
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Insulation Type | MI_RBICOMPO_INSUL_C | Character (200) |
A value is required if the value in the Insulated? cell is True. This cell may only contain one of the following values, which exist in the list in the Insulation Type field for RBI Component records:
If the family has been customized, the valid values could be different. This cell may only contain a value that exists in the list in the Insulation Type field for RBI Component records. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Injection Point Data | MI_CCRBICPI_INJ_PT_CIR_C | Character (50) | A value is required if the component type is Piping (i.e., the value in the Component Family cell is CCRBICPI). | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Piping Circuit Length | MI_CCRBICPI_PIP_CIR_LENG_N | Numeric |
A value is required if:
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||
PWHT | MI_RBICOMPO_PWHT_F | Boolean | Enter True or False. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Internal Corrosion Type | MI_RBICOMPO_INTER_CORR_TYPE_C | Character (50) |
A value is required if component is linked to RBI 581 Thinning and Lining Evaluation. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the CORROSION TYPES System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in yourAPM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Predictable Int. Corr. Location | MI_CCRBICOM_PRED_INT_COR_LOC_F | Boolean | Enter True or False. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Estimated Internal Corrosion Rate | MI_RBICOMPO_EXP_INT_CORR_RT_N | Numeric |
A value is required if:
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Estimated External Corrosion Rate | MI_RBICOMPO_EXP_EXT_CORR_RT_N | Numeric |
A value is required if:
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Measured External Corrosion Rate | MI_RBICOMPO_MEAS_EXT_COR_RT_N | Numeric | None | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Source of Calculated Corrosion Rates | MI_CCRBICOM_CALCD_CR_SRC_C | Character (50) |
In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_RBI_CALC_CORRO_SRC System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Percent Liquid Volume | MI_RBICOMPO_PER_LIQ_VOL_N | Numeric |
A value is required if you want to calculate inventory. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Detection System | MI_CCRBICOM_DETECTION_SYSTEM_C | Character (4) |
A value is required. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the 581_Detection System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Isolation System | MI_CCRBICOM_ISOLA_SYSTE_CHR | Character (50) |
A value is required. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the 581_Isolation System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Mitigation System | MI_CCRBICOM_MITIGATION_SYSTM_C | Character (60) |
A value is required. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the 581_Mitigation_System System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluid Velocity | MI_CCRBICOM_FLUID_VELOCITY_N | Numeric |
A value is required if an analysis in the component is linked to any of the following DMs:
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||
pH of Water | MI_CCRBICOM_PH_OF_WATER_N | Numeric |
A value is required if an analysis in the component is linked to any of the following DMs:
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Geometry Type | MI_CCRBICOM_GEOMETRY_TYPE_C | Character (60) |
A value is required if the component is linked to any of the following PDMs:
In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_Component_Geometry_Types System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
GFF Component Type | MI_CCRBICOM_GFF_COMPO_TYPE_CHR | Character (50) |
A value is required. This cell may only contain one of the following values, which exist in the list in the GFF Component Type field for RBI Component records:
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Cladding Present | MI_CCRBICOM_CLADDING_PRESENT_L | Character (50) |
A value is required if an associated analysis is linked to any of the following DMs:
In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Furnished Cladding Thickness | MI_CCRBICOM_CHR | Numeric | A value is required if the value in the Cladding Present cell is Y. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Minimum Structural Thickness | MI_CCRBICOM_MNMM_STRCTRL_THS_N | Numeric |
A value is required if the component is linked to any of the following PDMs:
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Liner Present | MI_CCRBICOM_LINER_PRESE_CHR | Character (50) |
A value is required if the component is linked to the RBI 581 Thinning and Lining Evaluation PDM. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. For the 581-Internal Component Lining Damage DM, the value in this cell must be Yes. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Liner Type | MI_CCRBICOM_LINER_TP_C | Character (50) |
A value is required if the value in the Liner Present cell is Y. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_Lining_Types_And_Resistance System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Has Release Prevention Barrier? | MI_CCRBICTB_HAS_RELEA_PREVE_F | Boolean |
A value is required if the value in the Component Type cell is Storage Tank Bottom. Enter True or False. If you enter True, then after you load data, the value in the Maximum Fill Height in AST field is populated with the value 0.25 feet. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
CM Corrosion Rate | MI_CCRBICOM_CM_COR_RT_C | Numeric |
A value is required if:
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Corrosion Allow | MI_RBICOMPO_CORRO_ALLOW_N | Numeric | None | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Is Intrusive? | MI_RBICOMPO_IS_INTRU_CHR | Character (50) |
A value is required if an analysis in the component is linked to any of the following DMs:
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Specified Tmin | MI_CCRBICOM_SPECIFIED_TMIN_N | Numeric | A value is required if the value in the Override Minimum Thickness cell is True. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Base Material | MI_CCRBICOM_BASE_MATER_C | Character (50) |
A value is required if an analysis in the component is linked to any of the following DMs:
This cell may only contain one of the values that exist in the list in the Base Material field for RBI Component records. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Cladding Material | MI_CCRBICOM_CLADDING_MATERIL_C | Character (50) |
A value is required if:
This cell may only contain one of the values that exist in the list in the Cladding Material field for RBI Component records. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Total Acid Number | MI_CCRBICOM_TOTAL_ACID_NUMBR_N | Numeric | A value is required if an analysis in the component is linked to the 581-High Temperature Sulfidic and Naphthenic Acid DM. |
RBI_581_Analysis Worksheet
In the RBI_581_Analysis worksheet, you will specify the analyses (which will be represented by RBI 581 Risk Analysis records) that you want to create. You cannot update an RBI 581 Risk Analysis using the data loader workbook.
Field Caption |
Field ID |
Data Type (Length) |
Comments | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Asset ID |
MI_EQUIP000_EQUIP_ID_C |
Character (255) |
Values in this column must match values entered in the Assets worksheet. Multiple analyses can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||||||
Asset CMMS System |
MI_EQUIP000_SAP_SYSTEM_C |
Character (255) |
Values in this column must match values entered in the Assets worksheet, if they exist. Multiple analyses can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||||||
Equipment Technical Number |
MI_EQUIP000_EQUIP_TECH_NBR_C |
Character (255) |
Values in this column must match values entered in the Assets worksheet, if they exist. Multiple components can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||||||
Component |
MI_RBICOMPO_COMPO_C | Character (250) | Values in this column must match values entered on the RBI_Component worksheet, if they exist. Multiple analyses can be linked to the same component (i.e., rows may have the same value in this column). | ||||||||||
Component Type |
MI_RBICOMPO_COMPO_TYPE_C | Character (60) |
Values in this column must match values that you entered in the Component Type column in the RBI_Component worksheet for the associated component. | ||||||||||
Analysis Unique ID | MI_ANALYSIS_ID | Character (255) | A value is required and must be unique. This value identifies the analysis. However, in the RBI 581 Risk Analysis records that are created by the data loader in APM, the value in the Analysis ID field is different from the value that you enter in this cell. | ||||||||||
Event Type | MI_CRITANAL_ANAL_TYPE_C | Character (1) | This column is not required. When this column exists and the value is W, the system searches for a What-If Analysis with an Analysis ID that matches the Analysis Unique ID column. | ||||||||||
Sub ID | MI_CRITANAL_SUB_ID_C | Character (50) | This column is not required. When this column exists and the value is provided, the value must match the existing Analysis Sub ID field. Note: The Sub ID field must be blank for analyses unless Event Type is set to W. | ||||||||||
Scenario ID | MI_CRITANAL_TURNAROUND_ID_C | Character (50) | None | ||||||||||
Coefficient Y Material | MI_581RANAL_COEFFICNT_Y_MTRL_C | Character (255) |
A value is required if the component type is Piping (i.e., the value in the Component Family cell is MI_CCRBICPI). In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_Coefficient_Materials System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||
Stress Override | MI_581RANAL_STRES_OVER_F | Boolean | Enter True or False. | ||||||||||
Allowable Stress | MI_CRITANAL_MTL_ALLOW_STRESS_N | Numeric | A value is required if the value in the Stress Override cell is True. | ||||||||||
Flow Stress | MI_581RANAL_FLOW_STRESS_N | Numeric | A value is required if the value in the Stress Override cell is True. | ||||||||||
Override Minimum Required Thickness | MI_581RANAL_OVERR_MINIM_REQUI_THICK_FLG | Boolean | Enter True or False. | ||||||||||
Course Number | MI_581RANAL_COURS_NUMBE_NBR | Numeric | A value is required if the analysis is linked to a component of type Storage Tank (i.e., the value in the Component Type cell in the RBI_Component worksheet for the associated component is Storage Tank). |
RBI_581_Consequence Worksheet
In the RBI_581_Consequence worksheet, you will specify the consequences (which are or will be represented by RBI 581 Consequence Evaluation records) that you want to create or update. You can create only one RBI 581 Consequence Evaluation for an RBI 581 Risk Analysis.
Field Caption |
Field ID |
Data Type (Length) |
Comments | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Asset ID |
MI_EQUIP000_EQUIP_ID_C |
Character (255) |
Values in this column must match values entered on the Assets worksheet. Multiple Consequence Evaluations can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||||||||||||||
Asset CMMS System |
MI_EQUIP000_SAP_SYSTEM_C |
Character (255) |
Values in this column must match values entered on the Assets worksheet, if they exist. Multiple Consequence Evaluations can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||||||||||||||
Equipment Technical Number |
MI_EQUIP000_EQUIP_TECH_NBR_C |
Character (255) |
Values in this column must match values entered on the Assets worksheet, if they exist. Multiple Consequence Evaluations can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||||||||||||||
Component |
MI_RBICOMPO_COMPO_C | Character (250) | Values in this column must match values entered on the RBI_Component worksheet, if they exist. Multiple Consequence Evaluations can be linked to the same component (i.e., rows may have the same value in this column). | ||||||||||||||||||
Component Type |
MI_RBICOMPO_COMPO_TYPE_C | Character (60) |
Values in this column must match values that you entered in the Component Type column on the RBI_Component worksheet for the associated component. | ||||||||||||||||||
Analysis Unique ID | MI_ANALYSIS_ID | Character (255) | Values in this column must match values entered on the RBI_581_Analysis worksheet. Each analysis can have only one Consequence Evaluation. | ||||||||||||||||||
Event Type | MI_CRITANAL_ANAL_TYPE_C | Character (1) | This column is not required. The value in this column must correspond to the value entered in the Event Type column on the RBI_581_Analysis worksheet. | ||||||||||||||||||
Sub ID | MI_CRITANAL_SUB_ID_C | Character (50) | This column is not required. The value in this column must match the value entered in the Sub ID column in the RBI_581_Analysis worksheet. | ||||||||||||||||||
Consequence | MI_RCONEVAL_CONS_C | Character (50) | A value is required in this cell if you are creating more than one Consequence Evaluation for the same analysis. If left blank, the Consequence field will be populated with the value RBI Consequence. | ||||||||||||||||||
Use Calculated Inventory | MI_RBI_EVN0_USE_CAL_INV_L | Boolean |
Enter True or False. If the value in this cell is True, values in the following cells in the RBI_Component worksheet for the associated component are required:
| ||||||||||||||||||
Inventory Group Mass | MI_RBI_EVN0_INV_GRP_MSS_N | Numeric |
A value is required if the value in the Component Family cell is not Storage Tank Bottom. | ||||||||||||||||||
Include Personnel Injury | MI_RBI_EVN0_INCLDPRSNNLNJRYG_L | Boolean | Enter True or False. | ||||||||||||||||||
Injury Cost | MI_RCONEVAL_INJUR_COST_N | Numeric | A value is required if the value in the Include Personnel Injury cell is True. | ||||||||||||||||||
Asset Cost | MI_RCONEVAL_EQU_COST_N | Numeric | A value is required if the value in the Component Type cell is not Storage Tank Bottom. | ||||||||||||||||||
Production Cost | MI_RCONEVAL_PROD_COST_N | Numeric | A value is required. | ||||||||||||||||||
Environmental Clean-up Costs | MI_RBI_EVN0_ENVIR_CLEAN_COSTS_NBR | Numeric | A value is required if the value in the Component Type cell is not Storage Tank Bottom. | ||||||||||||||||||
Allow Override of Total Financial Consequence | MI_RBI_EVN0_ALW_OVE_OF_TT_FC_FLAG | Boolean | Enter True or False. | ||||||||||||||||||
User Total Financial Consequences | MI_RBI_EVN0_USERTOTAL_FC_N | Numeric | A value is required if the value in the Allow Override of Total Financial Consequence cell is True. | ||||||||||||||||||
Cost Escalation Factor | MI_RBI_EVN0_CST_ESC_FAC_N | Numeric | If you do not enter a value, a value of 1 is considered to calculate the consequence. | ||||||||||||||||||
Maximum Fill Height in AST | MI_RBI_EVN0_MXM_FLL_HGT_AST_N | Numeric |
A value is required if, on the RBI_Component worksheet:
If, however, the value in the Has Release Prevention Barrier cell is True, after you load data, the Maximum Fill Height is AST field is populated with the value 0.25 feet irrespective of the value in this cell. | ||||||||||||||||||
Fluid Percent Leaving Dike | MI_RBI_EVN0_FLD_PRCT_LVG_DKE_N | Numeric | A value is required if the component type is Storage Tank or component type is Storage Tank Bottom and component family is Tank Bottom (i.e., the value in the Component Family column in the RBI_Component worksheet is MI_CCRBICTB). | ||||||||||||||||||
Fluid Percent Onsite | MI_RBI_EVN0_FLUD_PRCNT_ONSTE_N | Numeric | A value is required if the component type is Storage Tank or component type is Storage Tank Bottom and component family is Tank Bottom (i.e., the value in the Component Family column in the RBI_Component worksheet is MI_CCRBICTB). | ||||||||||||||||||
Fluid Percent Offsite | MI_RBI_EVN0_FLD_PRCNT_OFFSTE_N | Numeric | A value is required if the component type is Storage Tank or component type is Storage Tank Bottom and component family is Tank Bottom (i.e., the value in the Component Family column in the RBI_Component worksheet is MI_CCRBICTB). | ||||||||||||||||||
Environmental Sensitivity | MI_RBI_EVN0_ENVRNMNTL_SNSTVY_C | Character (50) |
A value is required if the component type is Storage Tank or component type is Storage Tank Bottom and component family is Tank Bottom (i.e., the value in the Component Family column in the RBI_Component worksheet is MI_CCRBICTB). In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_Environmental_Sensitivity System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||
Tank Course Height | MI_RBI_EVN0_TANK_COURSE_HGHT_N | Numeric | A value is required if the value in the Component Type cell is Storage Tank. | ||||||||||||||||||
Distance from Tankbottom to Groundwater | MI_RBI_EVN0_DSE_FRM_TNM_GRR_N | Numeric | A value is required if the value in the Component Type cell is Storage Tank Bottom. | ||||||||||||||||||
Soil Type under Tank bottom | MI_RBI_EVN0_SL_TYE_UNR_T_BTM_C | Character (50) |
A value is required if the value in the Component Type cell is Storage Tank Bottom. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_Soil_Types System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. |
DME_Lining Worksheet
On the DME_Lining worksheet, you will specify the 581-Atmospheric Tank Bottom Corrosion DMs (which are or will be represented by the RBI 581 Thinning and Lining Evaluation records) that you want to create or update. You can specify these records only if the value in the Liner Present cell in the RBI_Component worksheet for the associated component is Y.
Field Caption |
Field ID |
Data Type (Length) |
Comments | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Asset ID |
MI_EQUIP000_EQUIP_ID_C |
Character (255) |
Values in this column must match values entered in the Assets worksheet. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||||
Asset CMMS System |
MI_EQUIP000_SAP_SYSTEM_C |
Character (255) |
Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||||
Equipment Technical Number |
MI_EQUIP000_EQUIP_TECH_NBR_C |
Character (255) |
Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||||
Component |
MI_RBICOMPO_COMPO_C | Character (250) | Values in this column must match values entered in the RBI_Component worksheet, if they exist. Multiple DMs can be linked to the same component (i.e., rows may have the same value in this column). | ||||||||
Component Type |
MI_RBICOMPO_COMPO_TYPE_C | Character (60) |
Values in this column must match values that you entered in the Component Type column in the RBI_Component worksheet for the associated component. | ||||||||
Analysis Unique ID | MI_ANALYSIS_ID | Character (255) | Values in this column must match values entered in the RBI_581_Analysis worksheet, if they exist. Multiple DMs can be linked to the same analysis (i.e., rows may have the same value in this column). | ||||||||
Event Type | MI_CRITANAL_ANAL_TYPE_C | Character (50) | This column is not required. The value in this column must match the value entered in the Event Type column in the RBI_581_Analysis worksheet. | ||||||||
Sub ID | MI_CRITANAL_SUB_ID_C | Character (50) | This column is not required. The value in this column must match the value entered in the Sub ID column in the RBI_581_Analysis worksheet. | ||||||||
Damage Mechanism | MI_RBDEMEEV_DAM_MECH_C | Character (50) | Enter 581-Internal Component Lining Damage. | ||||||||
Last Known Inspection Date | MI_581DMCHE_LST_KNWN_INN_DTE_D | Date | Enter a value in the following format: YYYY-MM-DD hh:mm:ss | ||||||||
Online Monitoring Flag | MI_581DMCHE_ONLNE_MNTRNG_FLG_C | Character (50) |
A value is required. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||
Key Process Variable? | MI_581DMCHE_KEY_PROCSS_VRBLE_C | Character (3) |
A value is required if the value in the Online Monitoring Flag column is Y. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||
Electrical Resistance Probes? | MI_581DMCHE_ELCTRCL_RSSE_PRS_C | Character (3) |
A value is required if the value in the Online Monitoring Flag column is Y. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||
Corrosion Coupons? | MI_581DMCHE_CORROSION_COUPNS_C | Character (3) |
A value is required if the value in the Online Monitoring Flag column is Y. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||
Liner Installation Date | MI_581THNL_LIN_INST_DT_D | Date |
A value is required. Enter the value in the following format: YYYY-MM-DD hh:mm:ss | ||||||||
Liner Condition | MI_581THNL_LINER_COND_C | Character (50) |
A value is required. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_Lining_Condition System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||
Immersion Grade Coating Quality | MI_581THNL_IMMN_GRE_CTG_QLY_C | Character (50) |
A value is required if the liner type is organic coating (i.e., the value in the Liner Type column in the RBI_Component worksheet for the associated component is 2). In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_Coating_Quality System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. |
DME_AST Worksheet
In the DME_Lining worksheet, you will specify the 581-Atmospheric Tank Bottom Corrosion DM (which are or will be represented by the RBI 581 Thinning and Lining Evaluation records) that you want to create or update.
Field Caption |
Field ID |
Data Type (Length) |
Comments | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Asset ID |
MI_EQUIP000_EQUIP_ID_C |
Character (255) |
Values in this column must match values entered in the Assets worksheet. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||||||||
Asset CMMS System |
MI_EQUIP000_SAP_SYSTEM_C |
Character (255) |
Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||||||||
Equipment Technical Number |
MI_EQUIP000_EQUIP_TECH_NBR_C |
Character (255) |
Values in this column must match values entered in the Assets worksheet, if they exist. Multiple components can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||||||||
Component |
MI_RBICOMPO_COMPO_C | Character (250) | Values in this column must match values entered in the RBI_Component worksheet, if they exist. Multiple DMs can be linked to the same component (i.e., rows may have the same value in this column). | ||||||||||||
Component Type |
MI_RBICOMPO_COMPO_TYPE_C | Character (60) |
Values in this column must match values that you entered in the Component Type column in the RBI_Component worksheet for the associated component. | ||||||||||||
Analysis Unique ID | MI_ANALYSIS_ID | Character (255) | Values in this column must match values entered in the RBI_581_Analysis worksheet, if they exist. Multiple Consequences can be linked to the same analysis (i.e., rows may have the same value in this column). | ||||||||||||
Event Type | MI_CRITANAL_ANAL_TYPE_C | Character (1) | This column is not required. The value in this column must correspond to the value entered in the Event Type column on the RBI_581_Analysis worksheet. | ||||||||||||
Sub ID | MI_CRITANAL_SUB_ID_C | Character (50) | This column is not required. The value in this column must match the value entered in the Sub ID column in the RBI_581_Analysis worksheet. | ||||||||||||
Damage Mechanism | MI_RBDEMEEV_DAM_MECH_C | Character (50) | Enter 581-Atmospheric Tank Bottom Corrosion. | ||||||||||||
Selected Base Material Corrosion Rate | MI_581THNL_SELEC_BM_COR_R_C | Character (50) |
A value is required. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the 581_CORR_TYPE System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Liner Condition | MI_581THNL_LINER_COND_C | Character (50) |
A value is required if the liner present is Yes (i.e., the value in the Liner Present column in the RBI_Component worksheet for the associated component is Y). In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_Lining_Condition System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Immersion Grade Coating Quality | MI_581THNL_IMMN_GRE_CTG_QLY_C | Character (50) |
A value is required if the liner type is organic coating (i.e., the value in the Liner Type column in the RBI_Component worksheet for the associated component is 2). In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_Coating_Quality System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Long Term Avg Corr Rate | MI_581THNL_LNG_TRM_AVG_COR_R_N | Numeric |
A value is required if:
| ||||||||||||
Short Term Avg Corr Rate | MI_581THNL_SHRT_TRM_AVG_COR_N | Numeric |
A value is required if:
| ||||||||||||
Selected Cladding Material Corrosion Rate | MI_581THNL_SELEC_CLADD_COR_R_C | Character (50) |
A value is required if the value in the Cladding Present column in the RBI_Component worksheet for the associated component is Y. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the 581_CORR_TYPE System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Thinning Type | MI_RBDEMEEV_THIN_TYPE_C | Character (50) |
A value is required. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the CORROSION TYPES System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Highest Effective Inspection Level | MI_RBDEMEEV_HIGH_EFF_INSP_C | Character (25) |
A value is required. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_Inspection_Effectiveness System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Number of Highest Effective Inspections | MI_RBDEMEEV_NO_HIGH_EFF_INS_N | Numeric | A value is required, and should be either 0 or 1. If you enter 0 in this column, then the value in the Highest Effective Inspection Level column must be E. | ||||||||||||
Welded Construction Flag | MI_581DMCHE_WLDD_CNSTRCN_FLG_C | Character (50) |
A value is required. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
API 653 Maintenance Flag | MI_581THNL_API_653_MNTE_FLG_L | Boolean | A value is required. Enter True or False. | ||||||||||||
Foundation Type | MI_581DMCHE_FOUND_TYPE_CHR | Character (50) |
A value is required. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the FOUNDATION TYPES System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Settlement Adjustment Flag | MI_581DMCHE_STTLMNT_ADJT_FLG_C | Character (3) |
A value is required if the value in the Foundation Type column is not Concrete. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Settlement Adjustment Inspection | MI_581DMCHE_STTLMNT_ADJT_INN_C | Character (50) |
A value is required if the value in the Settlement Adjustment Flag column is Y. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_Recorded_Settlement_Criteria System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Online Monitoring Flag | MI_581DMCHE_ONLNE_MNTRNG_FLG_C | Character (50) |
A value is required. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Key Process Variable? | MI_581DMCHE_KEY_PROCSS_VRBLE_C | Character (3) |
A value is required if the value in the Online Monitoring Flag column is Y. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Electrical Resistance Probes? | MI_581DMCHE_ELCTRCL_RSSE_PRS_C | Character (3) |
A value is required if the value in the Online Monitoring Flag column is Y. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Corrosion Coupons? | MI_581DMCHE_CORROSION_COUPNS_C | Character (3) |
A value is required if the value in the Online Monitoring Flag column is Y. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Soil Resistivity | MI_581THNL_SOIL_RESIS_C | Numeric |
A value is required if the value in the Selected Base Material Corrosion Rate cell is Calculated Rate. | ||||||||||||
AST Pad | MI_581THNL_AST_PAD_C | Character (50) |
A value is required if the value in the Selected Base Material Corrosion Rate cell is Calculated Rate. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the 581_AST_PAD_MAT_TYPE System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
AST Drainage | MI_581THNL_AST_DRAINAGE_C | Character (50) |
A value is required if the value in the Selected Base Material Corrosion Rate cell is Calculated Rate. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the 581_AST_DRAINAGE_TYPE System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
AST Steam Coil Heater | MI_581THNL_AST_STEAM_CL_HTR_C | Character (50) |
A value is required if the value in the Selected Base Material Corrosion Rate cell is Calculated Rate. In the baselineAPM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_AST_STEAMCOIL_WATERDRWASOFF System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
AST Bottom Type | MI_581THNL_AST_BOTTOM_TYPE_C | Character (50) |
A value is required if the value in the Selected Base Material Corrosion Rate cell is Calculated Rate. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the 581_AST_BOTTOM_TYPE System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Cathodic Protection | MI_581THNL_CATHODIC_PROTCTN_C | Character (50) |
A value is required if the value in the Selected Base Material Corrosion Rate cell is Calculated Rate. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the 581_AST_Cathodic Protection System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Product Side Condition | MI_581THNL_PRODCT_SDE_CNDTN_C | Character (50) |
A value is required if the value in the Selected Base Material Corrosion Rate cell is Calculated Rate. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the 581_Product_Side_Condition System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Water Product Draws | MI_581THNL_WATER_PRDCT_DRWS_C | Character (50) |
A value is required if the value in the Selected Base Material Corrosion Rate cell is Calculated Rate. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_AST_STEAMCOIL_WATERDRWASOFF System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. |
DME_Thinning Worksheet
In the DME_Thinning worksheet, you will specify the following DMs (which are or will be represented by the RBI 581 Thinning and Lining Evaluation records) that you want to create or update.
-
581-High Temperature Oxidation
-
581-Cooling Water Corrosion
-
581-High Temperature H2/H2S Corrosion
-
581-Amine Corrosion
-
581-Hydrofluoric Acid Corrosion
-
581-Sulfuric Acid Corrosion
-
581-Hydrochloric Acid Corrosion
-
581-Acid Sour Water Corrosion
-
581-High Temperature Sulfidic and Naphthenic Acid
-
581-Alkaline Sour Water Corrosion
-
581-Soil Side Corrosion
These DMs belong to the RBI 581 Thinning and Lining Evaluation methodology. You can specify these DMs only if the value in the Component Type cell in the RBI_Component worksheet for the associated component is not Storage Tank Bottom.
Field Caption |
Field ID |
Data Type (Length) |
Comments | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Asset ID |
MI_EQUIP000_EQUIP_ID_C |
Character (255) |
Values in this column must match values entered in the Assets worksheet. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||||||||||||||||
Asset CMMS System |
MI_EQUIP000_SAP_SYSTEM_C |
Character (255) |
Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||||||||||||||||
Equipment Technical Number |
MI_EQUIP000_EQUIP_TECH_NBR_C |
Character (255) |
Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||||||||||||||||
Component |
MI_RBICOMPO_COMPO_C | Character (250) | Values in this column must match values entered in the RBI_Component worksheet, if they exist. Multiple DMs can be linked to the same component (i.e., rows may have the same value in this column). | ||||||||||||||||||||
Component Type |
MI_RBICOMPO_COMPO_TYPE_C | Character (60) |
Values in this column must match values that you entered in the Component Type column on the RBI_Component worksheet for the associated component. | ||||||||||||||||||||
Analysis Unique ID | MI_ANALYSIS_ID | Character (255) | Values in this column must match values entered in the RBI_581_Analysis worksheet, if they exist. Multiple DMs can be linked to the same analysis (i.e., rows may have the same value in this column). | ||||||||||||||||||||
Event Type | MI_CRITANAL_ANAL_TYPE_C | Character (1) | This column is not required. The value in this column must correspond to the value entered in the Event Type column on the RBI_581_Analysis worksheet. | ||||||||||||||||||||
Sub ID | MI_CRITANAL_SUB_ID_C | Character (50) | This column is not required. The value in this column must match the value entered in the Sub ID column in the RBI_581_Analysis worksheet. | ||||||||||||||||||||
Damage Mechanism | MI_RBDEMEEV_DAM_MECH_C | Character (50) |
In the baseline APM system, this cell may only contain one of the following values, which exist in the list in the Damage Mechanism field in the Potential Degradation Mechanisms record:
| ||||||||||||||||||||
Governing Thinning Damage Mechanism | MI_581THNL_GOV_THIN_DMG_MECH_C | Character (50) |
In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_GOV_THINNING_DAMAGE System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||
Last Known Inspection Date | MI_581DMCHE_LST_KNWN_INN_DTE_D | Date | Enter a value in the following format: YYYY-MM-DD hh:mm:ss | ||||||||||||||||||||
Last Known Thickness | MI_581DMCHE_LST_KNWN_THCKNSS_N | Numeric | A value is required if you entered a value in the Last Known Inspection Date cell. | ||||||||||||||||||||
Selected Base Material Corrosion Rate | MI_581THNL_SELEC_BM_COR_R_C | Character (50) |
A value is required. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the 581_CORR_TYPE System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||
Long Term Avg Corr Rate | MI_581THNL_LNG_TRM_AVG_COR_R_N | Numeric |
A value is required if:
| ||||||||||||||||||||
Short Term Avg Corr Rate | MI_581THNL_SHRT_TRM_AVG_COR_N | Numeric |
A value is required if:
| ||||||||||||||||||||
Selected Cladding Material Corrosion Rate | MI_581THNL_SELEC_CLADD_COR_R_C | Character (50) |
A value is required if the value in the Cladding Present column in the RBI_Component worksheet for the associated component is Y. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the 581_CORR_TYPE System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||
Number of A Level Inspections | MI_581DMCHE_NMR_OF_A_LVL_INS_N | Numeric | A value is required. | ||||||||||||||||||||
Number of B Level Inspections | MI_581DMCHE_NMR_OF_B_LVL_INS_N | Numeric | A value is required. | ||||||||||||||||||||
Number of C Level Inspections | MI_581DMCHE_NMR_OF_C_LVL_INS_N | Numeric | A value is required. | ||||||||||||||||||||
Number of D Level Inspections | MI_581DMCHE_NMR_OF_D_LVL_INS_N | Numeric | A value is required. | ||||||||||||||||||||
Thinning Type | MI_RBDEMEEV_THIN_TYPE_C | Character (50) |
A value is required. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the CORROSION TYPES System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||
Injection Point Flag | MI_581DMCHE_INJECTIN_PNT_FLG_C | Character (50) |
A value is required if the component type is piping (i.e., the value in the Component Family column in the RBI_Component worksheet for the associated component is MI_CCRBICPI). In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||
Injection Point Inspection | MI_581DMCHE_INJCTN_PNT_INSPN_C | Character (50) |
A value is required if the value in the Injection Point Flag column is Y. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||
Deadleg Flag | MI_581DMCHE_DEADLEG_FLAG_C | Character (50) |
A value is required if the component type is piping (i.e., the value in the Component Family column in the RBI_Component worksheet for the associated component is MI_CCRBICPI). In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||
Deadleg Inspection | MI_581DMCHE_DEADLEG_INSPECTN_C | Character (50) |
A value is required if the value in the Deadleg Flag column is Y. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||
Welded Construction Flag | MI_581DMCHE_WLDD_CNSTRCN_FLG_C | Character (50) |
In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||
API 653 Maintenance Flag | MI_581THNL_API_653_MNTE_FLG_L | Boolean | Enter True or False. | ||||||||||||||||||||
Foundation Type | MI_581DMCHE_FOUND_TYPE_CHR | Character (50) |
A value is required. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the FOUNDATION TYPES System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||
Settlement Adjustment Flag | MI_581DMCHE_STTLMNT_ADJT_FLG_C | Character (3) |
A value is required if the value in the Foundation Type column is not Concrete. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||
Settlement Adjustment Inspection | MI_581DMCHE_STTLMNT_ADJT_INN_C | Character (50) |
A value is required if the value in the Settlement Adjustment Flag column is Y. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_Recorded_Settlement_Criteria System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||
Online Monitoring Flag | MI_581DMCHE_ONLNE_MNTRNG_FLG_C | Character (50) |
A value is required. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||
Key Process Variable? | MI_581DMCHE_KEY_PROCSS_VRBLE_C | Character (3) |
A value is required if the value in the Online Monitoring Flag column is Y. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||
Electrical Resistance Probes? | MI_581DMCHE_ELCTRCL_RSSE_PRS_C | Character (3) |
A value is required if the value in the Online Monitoring Flag column is Y. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||
Corrosion Coupons? | MI_581DMCHE_CORROSION_COUPNS_C | Character (3) |
A value is required if the value in the Online Monitoring Flag column is Y. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||
Cl Concentration | MI_581THNL_HCL_CONCENTRATIN_N | Numeric | A value is required if the value in the Damage Mechanism column is 581-Cooling Water Corrosion. | ||||||||||||||||||||
Is Air or Oxidant Present? | MI_581THNL_IS_AR_OR_OXN_PRT_C | Character (50) |
A value is required if the Damage Mechanism column contains one of the following values:
| ||||||||||||||||||||
Soil Resistivity | MI_581THNL_SOIL_RESIS_C | Numeric | A value is required if the value in the Damage Mechanism column is 581-Soil Side Corrosion. | ||||||||||||||||||||
H2S Content | MI_581THNL_H2_CONTENT_N | Numeric | A value is required if the value in the Damage Mechanism column is 581-High Temperature H2/H2S Corrosion. | ||||||||||||||||||||
Hydrocarbon Type | MI_581THNL_HYDROCARBON_TYPE_C | Character (50) |
A value is required if the value in the Damage Mechanism column is 581-High Temperature H2/H2S Corrosion. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_HYDROCARBON_TYPES System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||
Sulphur Concentration | MI_581THNL_SULPHUR_CNCNTRTN_N | Numeric | A value is required if the value in the Damage Mechanism column is 581-High Temperature Sulfidic and Naphthenic Acid. | ||||||||||||||||||||
Cooling System Type | MI_581THNL_COOLI_SYSTE_TYPE_C | Character (50) |
A value is required if the value in the Damage Mechanism column is 581-Cooling Water Corrosion. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_Cooling_System System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||
Water Type | MI_581THNL_WATER_TYPE_C | Character (50) |
A value is required if the value in the Cooling System Type column is Once-Through. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_Water_Type System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||
Water Treatment Type | MI_581THNL_WATER_TREAT_TYPE_C | Character (50) |
A value is required if:
In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_Water_Treatment_Type System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||
Recirculating System Type | MI_581THNL_RECIR_SYSTE_TYPE_C | Character (50) |
A value is required if the value in the Cooling System Type column is Recirculating. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_Recirculating_System System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||
Calcium Hardness | MI_581THNL_CALCI_HARDN_N | Numeric |
A value is required if:
| ||||||||||||||||||||
Total Dissolved Solids | MI_581THNL_TOTAL_DISSO_SOLID_N | Numeric |
A value is required if:
| ||||||||||||||||||||
MO Alkalinity | MI_581THNL_MO_ALKAL_N | Numeric |
A value is required if:
| ||||||||||||||||||||
Oxygen in the Process Stream | MI_581THNL_OXYGN_ADJSTT_FCR_N | Numeric | A value is required if the value in the Damage Mechanism column is 581-Acid Sour Water Corrosion. | ||||||||||||||||||||
Acid Concentration | MI_581THNL_ACID_CONCENTRATN_N | Numeric | A value is required if the value in the Damage Mechanism column is 581-Sulfuric Acid Corrosion. | ||||||||||||||||||||
Soil Type | MI_581THNL_SOIL_TYPE_C | Character (50) |
A value is required if the value in the Damage Mechanism column is 581-Soil Side Corrosion. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the 581_Primary_Soil_Type System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||
Cathodic Protection Effectiveness | MI_581THNL_CATHO_PROTE_EFFEC_C | Character (50) |
A value is required if the value in the Damage Mechanism column is 581-Soil Side Corrosion. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_Cathodic Protection Effectiveness Factors System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||
Coating Present? | MI_581DMCHE_COATING_PRESENT_C | Character (3) |
A value is required if the value in the Damage Mechanism column is 581-Soil Side Corrosion. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||
Coating Age | MI_581DMCHE_COATING_AGE_N | Numeric |
A value is required if the value in the Coating Present? column is Y. | ||||||||||||||||||||
Maximum Coating Temperature Rating Exceeded? | MI_581THNL_MAXCOTEMP_EXCEE_C | Character (50) |
A value is required if the value in the Coating Present? column is Y. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||
Coating Maintenance Rare or None? | MI_581THNLCOATI_MAINT_NONE_C | Character (50) |
A value is required if the value in the Coating Present? column is Y. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||
Coating Type | MI_581THNL_COATINGTYPE_C | Character (50) |
A value is required if the value in the Coating Present? column is Y. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the 581_Coating_Type System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||
Amine Type | MI_581THNL_AMINE_TYPE_C | Character (50) |
A value is required if the value in the Damage Mechanism column is 581-Amine Corrosion. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_Amine_Types System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||
Heat Stable Amine Salts(HSAS) | MI_581THNL_HSAS_N | Numeric | A value is required if the value in the Damage Mechanism column is 581-Amine Corrosion. | ||||||||||||||||||||
Acid Gas Loading | MI_581THNL_ACID_GAS_LOADING_N | Numeric | A value is required if the value in the Damage Mechanism column is 581-Amine Corrosion. | ||||||||||||||||||||
Amine Concentration | MI_581THNL_AMINE_CONCENTRTN_N | Numeric | A value is required if the value in the Damage Mechanism column is 581-Amine Corrosion. | ||||||||||||||||||||
HF Concentration | MI_581THNL_HF_CONCE_NBR | Numeric | A value is required if the value in the Damage Mechanism column is 581-Hydrofluoric Acid Corrosion. | ||||||||||||||||||||
H2S Partial Pressure | MI_581THNL_H2S_PARTI_PRESS_NBR | Numeric | A value is required if the value in the Damage Mechanism column is 581-Alkaline Sour Water Corrosion. | ||||||||||||||||||||
NH4HS Concentration | MI_581THNL_NH4HS_CONCE_NBR | Numeric | A value is required if the value in the Damage Mechanism column is 581-Alkaline Sour Water Corrosion. |
DME_ExternalDamage Worksheet
In the DME_ExternalDamage worksheet, you can specify the following DMs that you want to create or update:
-
581-Ferritic Component Atmospheric Corrosion
-
581-Ferritic Component Corrosion Under Insulation
These DMs belong to the RBI 581 External Damage Evaluation methodology. These records will be linked to an RBI 581 Risk Analysis. You can specify these DMs only if the component type is not Tank Bottom (i.e., the value in the Component Family column in the RBI_Component worksheet is not MI_CCRBICTB).
Field Caption |
Field ID |
Data Type (Length) |
Comments | ||||||
---|---|---|---|---|---|---|---|---|---|
Asset ID |
MI_EQUIP000_EQUIP_ID_C |
Character (255) |
Values in this column must match values entered in the Assets worksheet. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||
Asset CMMS System |
MI_EQUIP000_SAP_SYSTEM_C |
Character (255) |
Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||
Equipment Technical Number |
MI_EQUIP000_EQUIP_TECH_NBR_C |
Character (255) |
Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||
Component |
MI_RBICOMPO_COMPO_C | Character (250) | Values in this column must match values entered in the RBI_Component worksheet, if they exist. Multiple DMs can be linked to the same component (i.e., rows may have the same value in this column). | ||||||
Component Type |
MI_RBICOMPO_COMPO_TYPE_C | Character (60) |
Values in this column must match values that you entered in the Component Type column on the RBI_Component worksheet for the associated component. | ||||||
Analysis Unique ID | MI_ANALYSIS_ID | Character (255) | Values in this column must match values entered in the RBI_581_Analysis worksheet, if they exist. Multiple DMs can be linked to the same analysis (i.e., rows may have the same value in this column). | ||||||
Event Type | MI_CRITANAL_ANAL_TYPE_C | Character (1) | This column is not required. The value in this column must correspond to the value entered in the Event Type column on the RBI_581_Analysis worksheet. | ||||||
Sub ID | MI_CRITANAL_SUB_ID_C | Character (50) | This column is not required. The value in this column must match the value entered in the Sub ID column in the RBI_581_Analysis worksheet. | ||||||
Damage Mechanism | MI_RBDEMEEV_DAM_MECH_C | Character (50) |
In the baseline APM system, this cell may only contain one of the following values, which exist in the list in the Damage Mechanism field in the Potential Degradation Mechanisms record:
| ||||||
Selected External Corrosion Rate | MI_581_XDME_SEL_EXT_CORR_RT_C | Character (50) |
A value is required. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_Corrosion_Rate System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||
Base Material Measured Rate | MI_RBDEMEEV_BM_MEASU_RT_N | Numeric | A value is required if the value in the Selected External Corrosion Rate cell is Estimated. | ||||||
Thinning Type | MI_RBDEMEEV_THIN_TYPE_C | Character (50) |
A value is required. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the CORROSION TYPES System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||
Coating Present? | MI_581DMCHE_COATING_PRESENT_C | Character (3) |
In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||
Coating Installation Date | MI_581DMCHE_CTNG_INSTLLN_DTE_D | Date | A value is required if the value in the Coating Present? cell is Y. Enter the value in the following format: YYYY-MM-DD hh:mm:ss | ||||||
Coating Quality | MI_RBDEMEEV_COAT_QUAL_C | Character (50) |
A value is required if the value in the Coating Present? cell is Y. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the 581_Coating_Quality System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||
Insulation Condition | MI_RBDEMEEV_INSUL_CON_C | Character (50) |
A value is required if the value in the Damage Mechanism cell is 581-Ferritic Component Corrosion Under Insulation. This cell may only contain one of the following values:
| ||||||
Piping System Complexity | MI_RBDEMEEV_PIP_SYS_COMPL_C | Character (50) |
A value is required if the value in the Damage Mechanism cell is 581-Ferritic Component Corrosion Under Insulation. This cell may only contain one of the following values:
| ||||||
Corrosion Rate Adjustment for bad Design/Fabrication | MI_581_XDME_ADJST_FR_DSN_FBN_C | Boolean | Enter True or False. | ||||||
Soil to Air Interface Present? | MI_581_XDME_SL_TO_AR_INE_PRT_L | Boolean | Enter True or False. | ||||||
Atmospheric Condition | MI_581_XDME_ATMOSPHERC_CNDTN_C | Character (50) |
A value is required if the value in the Selected External Corrosion Rate cell is Calculated. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_ATMOSPHERIC_CONDITION System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||
Last Known Inspection Date | MI_581DMCHE_LST_KNWN_INN_DTE_D | Date | Enter a value in the following format: YYYY-MM-DD hh:mm:ss | ||||||
Last Known Thickness | MI_581DMCHE_LST_KNWN_THCKNSS_N | Numeric | A value is required if you entered a value in the Last Known Inspection Date cell. | ||||||
Number of A Level Inspections | MI_581DMCHE_NMR_OF_A_LVL_INS_N | Numeric | A value is required. | ||||||
Number of B Level Inspections | MI_581DMCHE_NMR_OF_B_LVL_INS_N | Numeric | A value is required. | ||||||
Number of C Level Inspections | MI_581DMCHE_NMR_OF_C_LVL_INS_N | Numeric | A value is required. | ||||||
Number of D Level Inspections | MI_581DMCHE_NMR_OF_D_LVL_INS_N | Numeric | A value is required. |
DME_ExternalCracking Worksheet
In the DME_ExternalCracking worksheet, you can specify the following DMs that you want to create or update:
- 581-Austenitic Component Cracking Under Insulation
- 581-Austenitic Component Atmospheric Cracking
These DMs belong to the RBI 581 External Cracking Damage Evaluation methodology. These records will be linked to an RBI 581 Risk Analysis. You can specify these DMs only if the component type is not Tank Bottom (i.e., the value in the Component Family column in the RBI_Component worksheet is not MI_CCRBICTB).
Field Caption |
Field ID |
Data Type (Length) |
Comments | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Asset ID |
MI_EQUIP000_EQUIP_ID_C |
Character (255) |
Values in this column must match values entered in the Assets worksheet. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||||||||
Asset CMMS System |
MI_EQUIP000_SAP_SYSTEM_C |
Character (255) |
Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||||||||
Equipment Technical Number |
MI_EQUIP000_EQUIP_TECH_NBR_C |
Character (255) |
Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||||||||
Component |
MI_RBICOMPO_COMPO_C | Character (250) | Values in this column must match values entered in the RBI_Component worksheet, if they exist. Multiple DMs can be linked to the same component (i.e., rows may have the same value in this column). | ||||||||||||
Component Type |
MI_RBICOMPO_COMPO_TYPE_C | Character (60) |
Values in this column must match values that you entered in the Component Type column on the RBI_Component worksheet for the associated component. | ||||||||||||
Analysis Unique ID | MI_ANALYSIS_ID | Character (255) | Values in this column must match values entered in the RBI_581_Analysis worksheet, if they exist. Multiple DMs can be linked to the same analysis (i.e., rows may have the same value in this column). | ||||||||||||
Event Type | MI_CRITANAL_ANAL_TYPE_C | Character (1) | This column is not required. The value in this column must correspond to the value entered in the Event Type column on the RBI_581_Analysis worksheet. | ||||||||||||
Sub ID | MI_CRITANAL_SUB_ID_C | Character (50) | This column is not required. The value in this column must match the value entered in the Sub ID column in the RBI_581_Analysis worksheet. | ||||||||||||
Damage Mechanism | MI_RBDEMEEV_DAM_MECH_C | Character (50) |
In the baseline APM system, this cell may only contain one of the following values, which exist in the list in the Damage Mechanism field in the Potential Degradation Mechanism record:
| ||||||||||||
Number of Highest Effective Inspections | MI_RBDEMEEV_NO_HIGH_EFF_INS_N | Numeric | A value is required, and must be between 0 and 6. If you enter 0 in this column, then the value in the Highest Effective Inspection Level column must be E. | ||||||||||||
Highest Effective Inspection Level | MI_RBDEMEEV_HIGH_EFF_INSP_C | Character (25) |
A value is required. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_Inspection_Effectiveness System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Last Known Inspection Date | MI_581DMCHE_LST_KNWN_INN_DTE_D | Date | Enter a value in the following format: YYYY-MM-DD hh:mm:ss | ||||||||||||
Susceptibility Type | MI_581DMCHE_SUSCEPTBLTY_TYPE_C | Character (50) |
A value is required. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_Cracking_Susceptibility_Types System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Atmospheric Condition | MI_581_XCDME_ATMOS_CONDI_C | Character (50) |
A value is required if the value in the Susceptibility Type cell is Calculated. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_ATMOSPHERIC_CONDITION System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APMM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Susceptibility | MI_581DMCHE_SUSCEPTIBILITY_C | Character (50) |
A value is required if the value in the Susceptibility Type cell is Estimated. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_Cracking_Susceptibility System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Coating Present? | MI_581DMCHE_COATING_PRESENT_C | Character (3) |
A value is required. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Coating Installation Date | MI_581DMCHE_CTNG_INSTLLN_DTE_D | Date | A value is required if the value in the Coating Present? cell is Y. Enter the value in the following format: YYYY-MM-DD hh:mm:ss | ||||||||||||
Coating Quality | MI_RBDEMEEV_COAT_QUAL_C | Character (50) |
A value is required if the value in the Coating Present? cell is Y. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the 581_Coating_Quality System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Piping System Complexity | MI_RBDEMEEV_PIP_SYS_COMPL_C | Character (50) |
A value is required if the value in the Damage Mechanism cell is 581-Austenitic Component Cracking Under Insulation. This cell may only contain one of the following values:
| ||||||||||||
Insulation Condition | MI_RBDEMEEV_INSUL_CON_C | Character (50) |
A value is required if the value in the Damage Mechanism cell is 581-Austenitic Component Cracking Under Insulation. This cell may only contain one of the following values:
| ||||||||||||
Chloride Free Insulation | MI_581_XCDME_CHL_FREE_INSUL_C | Character (50) |
A value is required if the value in the Damage Mechanism cell is 581-Austenitic Component Cracking Under Insulation. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. |
DME_Cracking Worksheet
In the DME_Cracking worksheet, you can specify the following DMs that you want to create or update:
- 581-Amine Cracking
- 581-Alkaline Carbonate Stress Corrosion Cracking
- 581-HIC/SOHIC - HF
- 581-HIC/SOHIC - H2S
- 581-Caustic Cracking
- 581-Hydrogen Stress Cracking
- 581-Other Cracking
- 581-Sulfide Stress Cracking
- 581-Chloride Stress Corrosion Cracking
- 581-Polythionic Acid Cracking
These DMs belong to the RBI 581 Cracking Damage Evaluation methodology. These records will be linked to an RBI 581 Risk Analysis.
Field Caption |
Field ID |
Data Type (Length) |
Comments | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Asset ID |
MI_EQUIP000_EQUIP_ID_C |
Character (255) |
Values in this column must match values entered in the Assets worksheet. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||||||||
Asset CMMS System |
MI_EQUIP000_SAP_SYSTEM_C |
Character (255) |
Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||||||||
Equipment Technical Number |
MI_EQUIP000_EQUIP_TECH_NBR_C |
Character (255) |
Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||||||||
Component |
MI_RBICOMPO_COMPO_C | Character (250) | Values in this column must match values entered in the RBI_Component worksheet, if they exist. Multiple DMs can be linked to the same component (i.e., rows may have the same value in this column). | ||||||||||||
Component Type |
MI_RBICOMPO_COMPO_TYPE_C | Character (60) |
Values in this column must match values that you entered in the Component Type column on the RBI_Component worksheet for the associated component. | ||||||||||||
Analysis Unique ID | MI_ANALYSIS_ID | Character (255) | Values in this column must match values entered in the RBI_581_Analysis worksheet, if they exist. Multiple DMs can be linked to the same analysis (i.e., rows may have the same value in this column). | ||||||||||||
Event Type | MI_CRITANAL_ANAL_TYPE_C | Character (1) | This column is not required. The value in this column must correspond to the value entered in the Event Type column on the RBI_581_Analysis worksheet. | ||||||||||||
Sub ID | MI_CRITANAL_SUB_ID_C | Character (50) | This column is not required. The value in this column must match the value entered in the Sub ID column in the RBI_581_Analysis worksheet. | ||||||||||||
Damage Mechanism | MI_RBDEMEEV_DAM_MECH_C | Character (50) |
In the baseline APM system, this cell may only contain one of the following values, which exist in the list in the Damage Mechanism field in the Potential Degradation Mechanism record:
| ||||||||||||
Number of Highest Effective Inspections | MI_RBDEMEEV_NO_HIGH_EFF_INS_N | Numeric | A value is required, and must be between 0 and 6. If you enter 0 in this column, then the value in the Highest Effective Inspection Level column must be E. | ||||||||||||
Highest Effective Inspection Level | MI_RBDEMEEV_HIGH_EFF_INSP_C | Character (25) |
A value is required. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_Inspection_Effectiveness System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Last Known Inspection Date | MI_581DMCHE_LST_KNWN_INN_DTE_D | Date | Enter a value in the following format: YYYY-MM-DD hh:mm:ss | ||||||||||||
Susceptibility Type | MI_581DMCHE_SUSCEPTBLTY_TYPE_C | Character (50) |
A value is required. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_Cracking_Susceptibility_Types System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Susceptibility | MI_581DMCHE_SUSCEPTIBILITY_C | Character (50) |
A value is required only if the value in the Susceptibility Type cell is Estimated. If the value in the Susceptibility Type cell is Calculated or Detected, then APM will not consider the value that you enter in this cell. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_Cracking_Susceptibility System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Severity Index Adjustment Factor | MI_581DMCHE_SVRY_INX_ADT_FCR_N | Numeric |
A value is required if the value in the Damage Mechanism cell is 581-Other Cracking. In the baseline APM system, this cell may only contain one of the following values:
If the family has been customized, the valid values could be different. This cell may only contain a value that exists in the list in the Severity Index Adjustment Factor field for RBI 581 Cracking Damage Evaluation records. | ||||||||||||
Online Monitoring Flag | MI_581DMCHE_ONLNE_MNTRNG_FLG_C | Character (50) |
A value is required if the value in the Damage Mechanism cell is 581-HIC/SOHIC - H2S. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Key Process Variable? | MI_581DMCHE_KEY_PROCSS_VRBLE_C | Character (3) |
A value is required if the value in the Online Monitoring Flag cell is Y. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Hydrogen Probes | MI_581DMCHE_HYDROGEN_PROBES_C | Character (3) |
A value is required if the value in the Online Monitoring Flag cell is Y.
| ||||||||||||
Steam Out? | MI_581CRKEV_STEAM_OUT_C | Character (50) |
A value is required if:
In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Sulfur Content of Steel | MI_581CRKEV_SLFR_CNTT_OF_STL_C | Character (50) |
A value is required if:
In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_Sulfur_Content_Of_Steel System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Maximum Brinnell Hardness | MI_581CRKEV_MAX_BRIN_HARD_N | Numeric |
A value is required if:
| ||||||||||||
Heat Traced? | MI_581CRKEV_HEAT_TRACED_C | Character (50) |
A value is required if:
In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
H2S Water Content | MI_581DMCHE_H2S_WTR_CONT_N | Numeric |
A value is required if:
| ||||||||||||
Product Form | MI_581CRKEV_PRODUCT_FORM_C | Character (50) |
A value is required if:
In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_Product_Form System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
HF Present? | MI_581CRKEV_HF_PRESENT_C | Character (50) |
A value is required if:
In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Amine Solution Type | MI_581CRKEV_AMINE_SOLTN_TYPE_C | Character (50) |
A value is required if:
In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_Amine_Solution_Types System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Amine Type | MI_581CRKEV_AMINE_TYPE_C | Character (50) |
A value is required if:
In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_Amine_Types System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in yourAPM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Cyanides | MI_RBDEMEEV_CYANI_F | Boolean |
Enter True or False. | ||||||||||||
Caustic Type | MI_581CRKEV_CAUST_TYPE_C | Character (50) |
A value is required if:
In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_Caustic_Types System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
NaOH Caustic Concentration | MI_581CRKEV_NH_CSTC_CNCNTRTN_N | Numeric |
A value is required if:
| ||||||||||||
CO3 Concentration in Water | MI_581CRKEV_CO3_CONC_IN_WTR_N | Numeric |
A value is required if:
| ||||||||||||
Chloride Concentration Water Process | MI_581CRKEV_CH_CNC_OF_PR_WTR_C | Numeric |
A value is required if:
| ||||||||||||
Oxygen Concentration | MI_581CRKEV_O2_CONC_N | Numeric | The value in this column is used to calculate Susceptibility if the Susceptibility Type is Calculated and the Damage Mechanism is 581-Chloride Stress Corrosion Cracking. | ||||||||||||
Deposits Present | MI_581CRKEV_DEP_PRES_L | Boolean | Enter True or False. The value in this column is used to calculate Susceptibility if the Susceptibility Type is Calculated and the Damage Mechanism is 581-Chloride Stress Corrosion Cracking. | ||||||||||||
Exposure to Oxygen During Operation/Downtime | MI_581CRKEV_EXE_TO_OXN_D_OPE_C | Character (50) |
A value is required if:
In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Exposure to Sulfur During Operation/Downtime | MI_581CRKEV_EXE_TO_SLR_D_OPE_C | Character (50) |
A value is required if:
In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Exposure to Water During Operation/Shutdown | MI_581CRKEV_EXE_TO_WTR_D_OPN_C | Character (50) |
A value is required if:
In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Downtime Protection Used | MI_581CRKEV_DWNTME_PRTCN_USD_C | Character (50) |
A value is required if:
In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||
Thermal History (Heat Treatment History) | MI_581CRKEV_THL_HSY_HT_T_HSY_C | Character (50) |
A value is required if:
In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_Heat_Treatment_History System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. |
DME_HTHA Worksheet
In the DME_HTHA worksheet, you can specify the 581-High Temperature Hydrogen Attack DM that you want to create or update. This DM, however, is not applicable for a component of type Storage Tank Bottom.
Field Caption |
Field ID |
Data Type (Length) |
Comments | ||||||
---|---|---|---|---|---|---|---|---|---|
Asset ID |
MI_EQUIP000_EQUIP_ID_C |
Character (255) |
Values in this column must match values entered in the Assets worksheet. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||
Asset CMMS System |
MI_EQUIP000_SAP_SYSTEM_C |
Character (255) |
Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||
Equipment Technical Number |
MI_EQUIP000_EQUIP_TECH_NBR_C |
Character (255) |
Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||
Component |
MI_RBICOMPO_COMPO_C | Character (250) |
Values in this column must match values entered in the RBI_Component worksheet, if they exist. Multiple DMs can be linked to the same component (i.e., rows may have the same value in this column). | ||||||
Component Type |
MI_RBICOMPO_COMPO_TYPE_C | Character (60) |
Values in this column must match values that you entered in the Component Type column on the RBI_Component worksheet for the associated component. | ||||||
Analysis Unique ID | MI_ANALYSIS_ID | Character (255) | Values in this column must match values entered in the RBI_581_Analysis worksheet, if they exist. Multiple DMs can be linked to the same analysis (i.e., rows may have the same value in this column). | ||||||
Damage Mechanism | MI_RBDEMEEV_DAM_MECH_C | Character (50) |
Enter 581-High Temperature Hydrogen Attack. | ||||||
Event Type | MI_CRITANAL_ANAL_TYPE_C | Character (1) | This column is not required. The value in this column must correspond to the value entered in the Event Type column on the RBI_581_Analysis worksheet. | ||||||
Sub ID | MI_CRITANAL_SUB_ID_C | Character (50) | This column is not required. The value in this column must match the value entered in the Sub ID column in the RBI_581_Analysis worksheet. | ||||||
Is HTHA Damage Observed | MI_581_HTHA_IS_DAMAG_OBS_C | Character (50) |
A value is required. In the baselineAPM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||
Is Component Replaced | MI_581_HTHA_IS_COMPO_REPLA_C | Character (50) |
A value is required if the value in the Is HTHA Damage Observed cell is Y. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_YES_NO System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||
Exposure Hydrogen Partial Pressure | MI_581_HTHA_HYDRO_PAR_PRESS_N | Numeric |
A value is required if the value in the Is HTHA Damage Observed cell is N. | ||||||
Delta Temperature | MI_581_HTHA_DELTA_TEMPE_C | Character (50) |
A value is required if the value in the Is HTHA Damage Observed cell is N. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_HTHA_Delta_Temperature System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. |
DME_MechanicalFatigue Worksheet
Field Caption |
Field ID |
Data Type (Length) |
Comments | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Asset ID |
MI_EQUIP000_EQUIP_ID_C |
Character (255) |
Values in this column must match values entered in the Assets worksheet. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||||||||||||
Asset CMMS System |
MI_EQUIP000_SAP_SYSTEM_C |
Character (255) |
Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||||||||||||
Equipment Technical Number |
MI_EQUIP000_EQUIP_TECH_NBR_C |
Character (255) |
Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||||||||||||
Component |
MI_RBICOMPO_COMPO_C | Character (250) |
Values in this column must match values entered in the RBI_Component worksheet, if they exist. Multiple DMs can be linked to the same component (i.e., rows may have the same value in this column). | ||||||||||||||||
Component Type |
MI_RBICOMPO_COMPO_TYPE_C | Character (60) |
Values in this column must match values that you entered in the Component Type column on the RBI_Component worksheet for the associated component. | ||||||||||||||||
Analysis Unique ID | MI_ANALYSIS_ID | Character (255) | Values in this column must match values entered in the RBI_581_Analysis worksheet, if they exist. Multiple DMs can be linked to the same analysis (i.e., rows may have the same value in this column). | ||||||||||||||||
Damage Mechanism | MI_RBDEMEEV_DAM_MECH_C | Character (50) |
Enter 581-High Temperature Hydrogen Attack. | ||||||||||||||||
Event Type | MI_CRITANAL_ANAL_TYPE_C | Character (1) | This column is not required. The value in this column must correspond to the value entered in the Event Type column on the RBI_581_Analysis worksheet. | ||||||||||||||||
Sub ID | MI_CRITANAL_SUB_ID_C | Character (50) | This column is not required. The value in this column must match the value entered in the Sub ID column in the RBI_581_Analysis worksheet. | ||||||||||||||||
Previous Failure | MI_581MECHFT_PREVIOUS_FAIL_C | Character (50) |
A value is required. In the baselineAPM system, this cell may only contain one of the following System Code IDs:
| ||||||||||||||||
Visible/Audible Shaking | MI_581MECHFT_SHAKING_C | Character (50) |
A value is required. In the baselineAPM system, this cell may only contain one of the following System Code IDs:
| ||||||||||||||||
Shaking Frequency | MI_581MECHFT_SHAKING_DRTN_WKS_C | Character (50) |
A value is required. In the baselineAPM system, this cell may only contain one of the following System Code IDs:
| ||||||||||||||||
Cyclic Loading | MI_581MECHFT_CYCLIC_LOADING_C | Character (50) |
A value is required. In the baselineAPM system, this cell may only contain one of the following System Code IDs:
| ||||||||||||||||
Pipe Condition | MI_581MECHFT_PIPE_CONDITION_C | Character (50) |
A value is required. In the baselineAPM system, this cell may only contain one of the following System Code IDs:
| ||||||||||||||||
Corrective Action | MI_581MECHFT_CORREC_ACTIN_C | Character (50) |
A value is required. In the baselineAPM system, this cell may only contain one of the following System Code IDs:
| ||||||||||||||||
Branch Diameter | MI_581MECHFT_ADJST_FR_BRHDMR_C | Character (50) |
A value is required. In the baselineAPM system, this cell may only contain one of the following System Code IDs:
| ||||||||||||||||
Joint Type or Branch Design | MI_581MECHFT_ADT_FR_JNTT_DSN_C | Character (50) |
A value is required. In the baselineAPM system, this cell may only contain one of the following System Code IDs:
| ||||||||||||||||
Pipe Complexity | MI_581MECHFT_ADJST_FR_PPECMY_C | Character (50) |
A value is required. In the baselineAPM system, this cell may only contain one of the following System Code IDs:
|
DME_BrittleFracture Worksheet
In the DME_BrittleFracture worksheet, you can specify the following DMs that you want to create or update:
- 581-Sigma Phase Embrittlement
- 581-885F Embrittlement
- 581-Brittle Fracture
- 581-Low Alloy Steel Embrittlement
Field Caption |
Field ID |
Data Type (Length) |
Comments | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Asset ID |
MI_EQUIP000_EQUIP_ID_C |
Character (255) |
Values in this column must match values entered in the Assets worksheet. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||||||||||||||||||
Asset CMMS System |
MI_EQUIP000_SAP_SYSTEM_C |
Character (255) |
Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||||||||||||||||||
Equipment Technical Number |
MI_EQUIP000_EQUIP_TECH_NBR_C |
Character (255) |
Values in this column must match values entered in the Assets worksheet, if they exist. Multiple DMs can be linked to the same asset (i.e., rows may have the same value in this column). | ||||||||||||||||||||||
Component |
MI_RBICOMPO_COMPO_C | Character (250) | Values in this column must match values entered in the RBI_Component worksheet, if they exist. Multiple DMs can be linked to the same component (i.e., rows may have the same value in this column). | ||||||||||||||||||||||
Component Type |
MI_RBICOMPO_COMPO_TYPE_C | Character (60) |
Values in this column must match values that you entered in the Component Type column on the RBI_Component worksheet for the associated component. | ||||||||||||||||||||||
Analysis Unique ID | MI_ANALYSIS_ID | Character (255) | Values in this column must match values entered in the RBI_581_Analysis worksheet, if they exist. Multiple DMs can be linked to the same analysis (i.e., rows may have the same value in this column). | ||||||||||||||||||||||
Event Type | MI_CRITANAL_ANAL_TYPE_C | Character (1) | This column is not required. The value in this column must correspond to the value entered in the Event Type column on the RBI_581_Analysis worksheet. | ||||||||||||||||||||||
Sub ID | MI_CRITANAL_SUB_ID_C | Character (50) | This column is not required. The value in this column must match the value entered in the Sub ID column in the RBI_581_Analysis worksheet. | ||||||||||||||||||||||
Damage Mechanism | MI_RBDEMEEV_DAM_MECH_C | Character (50) |
In the baseline APM system, this cell may only contain one of the following values, which exist in the list in the Damage Mechanism field in the Potential Degradation Mechanism record:
| ||||||||||||||||||||||
Material Exemption Curve | MI_581BRFRAC_MTRL_EXMPTNCRVE_N | Character (50) |
A value is required if the value in the Damage Mechanism cell is 581-Brittle Fracture or 581-Low Alloy Steel Embrittlement. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_Material_Temperature_Exemption_Curves System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. | ||||||||||||||||||||||
Minimum Allowable Temperature | MI_581BRFRAC_MNMM_ALLWBLETME_N | Numeric |
A value is required if the Damage Mechanism cell contains one of the following values:
| ||||||||||||||||||||||
Minimum Design Metal Temperature (MDMT) | MI_581BRFRAC_MNM_DSN_MTL_MDT_N | Numeric |
A value is required if the Damage Mechanism cell contains one of the following values:
| ||||||||||||||||||||||
Critical Exposure Temperature(CET) | MI_581BRFRAC_CRTCLEXPSRE_TMT_N | Numeric |
A value is required if the value in the Damage Mechanism cell is 581-Brittle Fracture. | ||||||||||||||||||||||
Is CET at the MAWP >= -29°C | MI_581BRIFRAC_IS_CT_PVPCRT_L | Boolean | Enter True or False. | ||||||||||||||||||||||
Is Cyclic service Design Requirement | MI_581BRIFRAC_IS_CYC_SREFRQT_L | Boolean | Enter True or False. | ||||||||||||||||||||||
Is Asset Or Circuit Subject to EVN Cracking | MI_581BRIFRAC_IS_EQT_CRCRG_L | Boolean | Enter True or False. | ||||||||||||||||||||||
Is Asset Or Circuit Subject to Shock Chilling | MI_581BRIFRAC_IS_EQT_CR_SCHG_L | Boolean | Enter True or False. | ||||||||||||||||||||||
Is Fabricated From P-1 and P-3 Steels | MI_581BRIFRAC_IS_FBD_FRMP65F_L | Boolean | Enter True or False. | ||||||||||||||||||||||
Is Nominal Operating Conditions Changed | MI_581BRIFRAC_IS_NML_OPGCCHD_L | Boolean | Enter True or False. | ||||||||||||||||||||||
Is Nominal Uncorroded Thickness < 50.8 mm (2 inch) | MI_581BRIFRAC_NML_UNDTHS_INH_L | Boolean | Enter True or False. | ||||||||||||||||||||||
Is Satisfied All Requirements For Fabrication | MI_581BRIFRAC_IS_STD_ALLRFRN_L | Boolean | Enter True or False. | ||||||||||||||||||||||
Fracture Appearance Transition Temperature(FATT) | MI_581BRFRAC_FRCEAPE_TRN_TME_N | Numeric | A value is required if the value in the Damage Mechanism cell is 581-Low Alloy Steel Embrittlement. | ||||||||||||||||||||||
Sigma Percentage | MI_581BRIFRAC_SIGMA_AMOUNT_N | Numeric |
A value is required if the value in the Damage Mechanism cell is 581-Sigma Phase Embrittlement. In the baseline APM system, this cell may only contain one of the following System Code IDs:
The list in this field is populated by the MI_581_Sigma_Percentage System Code Table. If the system code table has been customized, the valid values could be different. To verify which options are acceptable in your APM system, via Configuration Manager, refer to the appropriate table. |