V4.3.0.3.8.1 Deployment
About Applying This Patch
How do I Know if I Need This Patch?
You must apply this patch if your current version is V4.3.0.3.0 through V4.3.0.3.8, and you are using Asset Health Manager.
For details, refer to the release notes for this patch.
Applying V4.3.0.3.8.1
To apply this patch, complete the following steps:
- Apply this patch to all instances of the GE Digital APM Server (both dedicated and supporting).Important: This patch can be applied to any machine where V4.3.0.0.0 is currently running. To ensure that the machine is updated to the baseline database content, you must complete steps 2 through 5 if you have not completed them when applying a previous release.
- If you are using Calibration Management, using the command prompt, navigate to the <GE Digital APM installation folder>\Upgrade folder, and then run the following command:
Meridium.DbUtility.PostUpgrade.exe -x:<path>/CalibrationDataModelUpgradeUtility.xml -d:<datasource ID> -u:<user name> -p:<password>
Where:
- <path> is the folder path of the file CalibrationDataModelUpgradeUtility.xml.Tip: The default path is C:\Meridium\DbUpg\MI_DB_MASTER_4030003\4030003\_99_PostProcess\_files. If, however, you have provided a different location to save and extract zip files, then you can search for the folder path in the Windows registry under HKEY_LOCAL_MACHINE\SOFTWARE\Meridium\APM\InstallInfo.
- <datasource ID> identifies the GE Digital APM datasource.
- <user name> is the GE Digital APM user name.
- <password> is the GE Digital APM password.
- <path> is the folder path of the file CalibrationDataModelUpgradeUtility.xml.
- If you are using one of the following modules, import the needed files:
- Calibration Management
- Reliability Analytics
- Root Cause Analysis
- Rounds Designer
- Rounds
- If you are using Root Cause Analysis:
- If you are using a module that uses the MI_TASK family, run the upgrade script to update the existing records.
- Apply this patch to mobile devices using an iOS, Android, or Windows operating system by following the standard documentation for installing the GE Digital APM mobile application.
The files that you need to apply this patch are included in the distribution package.
Apply This Patch to GE Digital APM Server Instances
Procedure
Import Files
Procedure
Enable State Management for the RCA Analysis Family
- Access Configuration Manager, and then select Family Management.
- In the family hierarchy, search for and select RCA Analysis.
The workspace for the RCA Analysis family appears.
- In the workspace, select State Configuration.
- Select Enable State Functionality.
- Clear the Show States on Datasheets check box.
- Select Add States, and then add states. The following table provides values that you can use to create states.
ID Caption Initial State Not Started Not Started Yes In Progress In Progress No On Hold On Hold No Deferred Deferred No Completed Completed No - Select Add Operation, and then add operations. The following table provides values that you can use to create operations.
ID Caption Predecessor State Successor State Start Start Not Started In Progress Hold Hold In Progress On Hold Continue Continue On Hold In Progress Defer Defer In Progress Deferred Complete Complete In Progress Completed - Select Save.
State Management is enabled for the RCA Analysis family.
Remove Status Field from the RCA Recommendation Datasheet
Procedure
Run the Upgrade Script
If you are using a module that uses the MI_TASK family, run the RUN_SCRIPT.cmd file to update the values in the Task State field in the existing records as follows:
Existing Value | Updated Value |
---|---|
Proposed | PROPOSED |
Scheduled with change | SCHEDULED WITH CHANGE |
Scheduled without change | SCHEDULED WITHOUT CHANGE |
- Install the database client.Note: If the database client is not installed, an error message appears, indicating that the database client is not recognized, and the script will not run as expected.
- Navigate to the folder <Distribution Package>\General Release\Meridium APM Setup\Database\Update Task State.
- If you are using an Oracle database, copy the folder ORA to a local or mapped drive that is accessible from the machine in which you will run the script.
-or-
If you are using an SQL database, copy the folder SQL to a local or mapped drive that is accessible from the machine in which you will run the script.
Note: Make sure that the folder name does not contain space. - From the copied folder, run the file RUN_SCRIPT.cmd, and then follow the on-screen instructions.
Values in the Task State field will be updated in the existing records.
A log file is generated. If the log file contains errors, contact the technical product support.
Install the GE Digital APM Mobile Application on an iOS Device
GE Digital provides an iOS app, but there are specific steps that must be taken for an organization to install the GE Digital APM mobile application on iOS devices.
Before you begin
Before the application can be installed, an Apple developer's license must be purchased.
Procedure
Install the GE Digital APM Mobile Application on an Android Device
GE Digital provides an Android app, but there are specific steps that must be taken for an organization to install the GE Digital APM mobile application on Android devices.