V4.5.0.0.4 Deployment

About Applying This Patch

How do I Know if I Need This Patch?

You must apply this patch if your current version is V4.5.0.0.0 through V4.5.0.0.3 and you are using one or more of the following modules or features:
  • Asset Criticality Analysis
  • APM Mobile Application
  • Calibration Management
  • eLog
  • Family Management
  • Family Policies
  • Generation Availability Analysis
  • Inspection Management
  • Metrics and Scorecards
  • OT Connect
  • SIS Management
  • Thickness Monitoring

For details, refer to the release notes for this patch.

Applying V4.5.0.0.4

To apply this patch, complete the following steps:

  1. Apply this patch to all instances of the GE Digital APM Server (both dedicated and supporting).
  2. Apply this patch to mobile devices using an iOS, Android, or Windows operating system by following the standard documentation for installing the GE Digital APM mobile application.
  3. Uninstall the previous version of the Meridium Device Service, and install the latest version of the Meridium Device Service on all of the machines that is used to connect datalogger devices with Thickness Monitoring.
    Note: This step is required only if you will use a datalogger device to collect data that you transfer to Thickness Monitoring.
  4. If you are using OT Connect, perform the following steps:
    1. Remove all OT Connect Adapters, and then reinstall them from the 4.5.0.0.4 OTConn installer available in the distribution package.
    2. Re-enter the password for any OSI PI or GE Historian OT Source in the Connections section.

The files that you need to apply this patch are included in the distribution package.

Install the GE Digital APM Mobile Application on an iOS Device

GE Digital provides an iOS application, but there are specific steps that you must perform to install the GE Digital APM mobile application on iOS devices.

Before You Begin

An Apple developer's license must be purchased.

Procedure

  1. Access the application package file at C:\Program Files\Meridium\ApplicationServer\distribution\GEDigitalAPM.ipa.
    Note: This is the default location of the application package file. The exact location at which you can obtain the application package file may differ based on your initial installation of GE Digital APM.
  2. Sign the application using the production certificate, private key, application identifier, and distribution provisioning profile created through https://developer.apple.com/programs/enterprise/.
    The GE Digital APM Mobile Application is installed on the iOS Device.
  3. Optional: If your organization does not use mobile device management, complete the following steps to distribute the application within your organization:
    1. In Notepad or a similar text editor, copy and paste the following text:
      <?xml version="1.0" encoding="UTF - 8"?>
      <!DOCTYPE plist PUBLIC " -//Apple//DTD PLIST 1.0//EN" "http://www.apple.com/DTDs/PropertyList-1.0.dtd">
      <plist version="1.0">
      <dict>
      	<key>items</key>
      	<array>
      		<dict>
      			<key>assets</key>
      			<array>
      				<dict>
      					<key>kind</key>
      					<string>software-package</string>
      					<key>url</key>
      					<string>https://<your_server_url>/GEDigitalAPM.ipa</string>
      				</dict>
      			</array>
      			<key>metadata</key>
      			<dict>
      				<key>bundle-identifier</key>
      				<string><your_application_identifier></string>
      				<key>kind</key>
      				<string>software</string>
      				<key>title</key>
      				<string>GEDigitalAPM</string>
      			</dict>
      		</dict>
      	</array>
      </dict>
      </plist>
    2. Replace <your_server_url> with the URL of your server.
    3. Replace <your_application_identifier> with an identifier for your application.
    4. Save the file as GEDigitalAPM.plist, and then close the file.
      The .plist file is created. When you configure a distribution page for your application, link to this file.
    5. In the web page from which you want to distribute the application within your organization, add an anchor tag with an href pointing to the installation file, as shown in the following example:
      <a href="itms-services://?action=download-manifest&url=https://my.company.com/GEDigitalAPM.plist">Install GE Digital APM</a>

    You can use the link you configured to distribute the application within your organization.

Install the GE Digital APM Mobile Application on an Android Device

GE Digital provides an Android application, but there are specific steps that you must perform to install the GE Digital APM mobile application on Android devices.

Procedure

  1. Access the application package file at C:\Program Files\Meridium\ApplicationServer\distribution\GEDigitalAPM.apk.
    Note: This is the default location of the application package file. The exact location at which you can obtain the application package file may differ based on your initial installation of GE Digital APM.
  2. Optional: If your organization does not use mobile device management, in the web page from which you want to distribute the application within your organization, add an anchor tag with an href pointing to the installation file, as shown in the following example:
    <a href="my.company.com/GEDigitalAPM.apk">Install GE Digital APM</a>

    You can use the link you configured to distribute the application within your organization.

Install the GE Digital APM Mobile Application on a Windows Device

Procedure

  1. Access the application package file at C:\Program Files\Meridium\ApplicationServer\distribution\GEDigitalAPM.zip.
    Note: This is the default location of the application package file. The exact location at which you can obtain the application package file may differ based on your initial installation of GE Digital APM.
  2. Access the application package file at C:\Program Files\Meridium\ApplicationServer\distribution\GEDigitalAPM.zip.
    Note: This is the default location of the application package file. The exact location at which you can obtain the application package file may differ based on your initial installation of GE Digital APM.
  3. On the device on which you want to install the GE Digital APM mobile application, extract the content of the application package file to a local folder.
  4. In the folder into which you extracted the application package file content, right-click Install.bat, and then select Run as an Administrator.
    Note: If you are using a touch-screen device, press and hold Install.bat, and then select Run as an Administrator.
    The GE Digital APM mobile application is installed on the Windows device for all current and future Windows user accounts.
  5. Optional: To cancel future installations or uninstall the GE Digital APM mobile application, in the folder into which you extracted the application package file content, right-click Uninstall.bat, and then select Run as an Administrator.
    Note: If you are using a touch-screen device, press and hold Uninstall.bat, and then select Run as an Administrator.
    The GE Digital APM mobile application is uninstalled for the Windows user account that is currently logged in, and installations for future Windows user accounts are canceled.

Install the Latest Version of the Meridium Device Service

About This Task

To apply the update to resolve the datalogger issue, you must uninstall the previous version of the Meridium Device Service, and install the latest version of the Meridium Device Service.
Note: If the URL is secured (https), follow the instructions in HOW TO: V4 Thickness Monitoring - Devices - Dataloggers and Secure HTTPS Browsers on Windows Machines KBA 2850 to install the Meridium Device Service.

Procedure

  1. On the computer, access the Uninstall or Change a Program section of the Control Panel.
  2. Select Meridium Device Service, right-click, and then select Uninstall.
    The Meridium Device Service is uninstalled.
  3. Restart the computer.
  4. Access the Access Dataloggers page.
  5. Select Send.
    Note: A datalogger does not need to be connected.
    The Meridium Device Service Not Found window appears.
  6. Select the Download link.
    MeridiumDevices.exe is downloaded.
  7. Run MeridiumDevices.exe, and then follow the instructions in the installer.
    The Meridium Device Service is installed.
  8. In the Meridium Device Service Not Found window, select Continue.
    Dataloggers can now be used with Thickness Monitoring.

Run OT Connect Tag Sync Utility

About This Task

The OT Connect Tag Sync Utility assists in Tag Sync troubleshooting. This can be used to test the Tag Sync without installing an adapter service.

Procedure

  1. Open the C:\Program Files\Meridium\Services\OTConnect\Adapters\{name}\appsettings.json file in a text editor, and then configure it to connect to the process historian or OPC server that you want to investigate.
  2. Open Command Prompt, and then run C:\Program Files\Meridium\Services\OTConnect\Adapters\{name}\APM.OTConnect.Adapter.exe tags.
    The exact Source Tag metadata collected from the process historian is written to a file, tags.csv in the working directory.

Run Portable OT Connect Capability and Tag Sync Utilities

About This Task

An archive containing the APM.OTConnect.Adapter.exe and all required libraries are available with the GE Digital APM distribution package. You can use this to run the OT Connect utilities without installing a service.

Procedure

  1. Extract the archive to a working directory.
  2. Update the appsettings.json file in the working directory. For more information, refer to the https://www.ge.com/digital/documentation/apm-classic/otc-working-with-ot-source-capability-utility.html#otc-working-with-ot-source-capability-utility topic.
  3. To run the Portable OT Connect Capability Utility, run APM.OTConnect.Adapter.exe check.