Records in the Tank T-Min Annular Ring family make up the Tank T-Min Annular Ring reference table, which GE Digital APM uses to locate the appropriate Calculated T-Min value for each Thickness Measurement Location (TML) with the value API 653 in the Design Code field and Annular Ring in the Tank Type field.
The baseline GE Digital APM product does not include any records in the Tank T-Min Annular Ring family. For Calculated T-Min values to be determined, you must create Tank T-Min Annular Ring records using values from industry standards.
The following table lists the default fields in the Tank T-Min Annular Ring family and the corresponding fields in the Thickness Measurement Location family.
Tank T-Min Annular Ring Field | Corresponding TML Field | Notes |
---|---|---|
Hydrostatic Test Stress Lower Bound | Allowable Stress | The Hydrostatic Test Stress Lower Bound field establishes the lower boundary of a stress range. An Allowable Stress value from a TML that falls within the established range is considered a match. |
Hydrostatic Test Stress Upper Bound | Allowable Stress | The Hydrostatic Test Stress Upper Bound field establishes the upper boundary of a stress range. An Allowable Stress value from a TML that falls within the established range is considered a match. |
Plate Thickness Lower Bound | Plate Thickness | The Plate Thickness Lower Bound field establishes the lower boundary of a plate thickness range. A Plate Thickness value from a TML that falls within the established range is considered a match. |
Plate Thickness Upper Bound | Plate Thickness | The Plate Thickness Upper Bound field establishes the upper boundary of a plate thickness range. A Plate Thickness value from a TML that falls within the established range is considered a match. |
T-Min | Minimum Thickness | The T-Min value that corresponds to the stress range and plate thickness range identified by the Allowable Stress and Plate Thickness values in the TML becomes the Calculated T-Min value for that record. This value can be used to populate the Minimum Thickness field in the TML, or a user-defined value can be specified instead. |
Copyright © 2018 General Electric Company. All rights reserved.