On the GE Digital APM Server, navigate to Meridium/Upgrade/DBUpgrade, and then open the file RevertToBaselineApp.exe.
The Revert To Baseline Login Screen window appears.
Enter a valid data source, user name, and password, and then select Next.
Note: The value in the Meridium Data Source box should match exactly the Data Source ID of the data source.
The Revert To Baseline screen appears, displaying the families that you can revert to baseline.
Select the row containing the family whose element you want to revert to baseline, and then select Revert To Baseline.
Tip: You can enter a value in the Search box to search for a specific family.
Note: If you want to revert records and links for a family for which the value in the Is Composite Family column is Yes, you will need to revert the records and links for the parent family of that family. If this is the case, based on the following table, please select the appropriate parent family for the child family whose records and links you want to revert to baseline.
Child Family to Revert | Parent Family to Select |
---|---|
MI_STRMAPP | MI_STMPCNFG |
MI_RRSKMDT | MI_RRSKMAP |
MI_CLMND_PR MI_MPPG_QRY |
MI_DATA_GRP |
MI_PROTDEFI MI_RISKTHRE MI_PROBDEFI MI_CONSDEFI MI_RISKCATE |
MI_RISKMATR |
The Various Options For Revert window appears.
Select the check box for the revert to baseline action that you want to execute, and then select OK.
If you selected the Associated Pages, Datasheets, Privileges, Project, or Behavior check box, the Success window appears, displaying a message indicating that the revert to baseline action has been completed. The following image shows the Success window after the action of reverting Privileges to baseline has been completed.
Select OK.
The Success and Various Options For Revert windows close.
-or-
If you selected the Records and Link check box, the Revert to Baseline - Records and Links window appears.
In the list on the left side of the window, select the family that contains the records and links that you want to revert to baseline.
The selected records and links appear in the list on the right side of the window.
If you want to revert the records and links for records in the family, in the list on the right side of the window, select the check box next to each record that you want to revert to baseline, and then select Revert Selected.
-or-
If you want to revert customized template values for the family to baseline, select a family on the left side of the window, and then, in the My Template Defaults row that appears, select Compare. Then, on the My Template Defaults window that appears, select Revert.
A message appears, indicating that the selected records and links have been reverted to baseline.
-or-
If you selected the State Management check box, the State Management Mapper window appears.
The family of the item that you selected in the Comparison Results grid is highlighted in the tree in the Entity Families section of the State Management Mapper window. In the Custom section, a list of the customized states for the family appears. In the Baseline section, a list of the baseline states for the family appears.
The customized states for the family also appear in the Custom Source column in the grid in the State Management Baseline Mapping section.
In the State Management Baseline Mapping section, in each cell in the Select Target column, select the baseline target for each customized state in the Custom Source column.
The selected targets appear in the cells in the Baseline Target column.
Select Revert Single Family or Revert Multiple.
If you selected Revert Single Family, a message appears, asking if you want to save the current mapping and revert to it.
Select Yes.
A confirmation message appears.
Select OK.
The selected states are converted.
-or-
If you selected Revert Multiple, the Browse For Folder window appears.
Navigate to the folder containing all of the families whose states you want to convert, and then select OK.
A message appears, asking you to confirm that you want to continue.
Select Yes.
A confirmation message appears.
Select OK.
The selected states are converted.