Calibration, CMX Records

Calibration, CMX record is a type of Calibration record that stores information about the calibration events that you have created manually for calibration profiles of type Calibration Template, CMX or events that you have received from Beamex CMX calibration software. This topic provides an alphabetical list and description of the fields that exist for the Calibration, CMX family. The information in this table reflects the baseline state and behavior of these fields. This list is not comprehensive.

This family is enabled for site filtering, which means that records in this family can be assigned to a specific site, and will then only be accessible to users who are assigned to the same site and have the appropriate license and family privileges. See the Site Filtering section of the documentation for more information on using this feature.

Field Data Type Description Behavior and Usage
Ad-Hoc Calibration Boolean

Indicates that the calibration is performed on the equipment that needs to be calibrated outside of its calibration schedule.

For example, suppose a piece of equipment has an annual calibration task in January. If the equipment needs a repair or replacement during the year, after the equipment is repaired or replaced, the equipment should be calibrated. An Ad-Hoc calibration is performed in this scenario.

By default, this check box is cleared. If you select this check box, after you perform the calibration, the associated Calibration Task is not recycled.
Asset ID Character The Identification of the equipment that you have calibrated.

This field is populated with the Equipment ID of the piece of equipment that is linked to the Calibration.

This field is labeled Select Equipment on the datasheet. You can select the Equipment ID hyperlink to view the Equipment details.

Asset Short Description Character A brief description of the asset that you have calibrated.

This field is populated with the value stored in the Equipment Short Description field in the Equipment that is linked to the Calibration.

This field is labeled Equipment Short Description on the datasheet. You can modify this value if needed.

Asset Type Character The type of the asset that you have calibrated.

This field is populated with the value stored in the Equipment Type field in the Equipment that is linked to the Calibration.

This field is labeled Equipment Type on the datasheet. You can modify this value if needed.

Calibration Approval By Character The name and User ID of the user who approved the calibration. This field contains a list of user names. You can select the appropriate user from the list.
Calibration Error Limit Numeric A number indicating the maximum percentage of acceptable error before the calibration is considered to be failed.

This field is populated with the value stored in the Max Error Limit field of the Calibration Template that is linked to this Calibration. You can modify this value if needed.

Calibration Passed Character A value that indicates whether the calibration passed or failed.

In automated calibration, this field is populated based on the calibration results that are received from the Beamex CMX calibration software.

In manual calibration, you can select one of the following values that are defined in the MI_CALIBRATION_RESULT System Code Table, to indicate the result of calibration:

  • PASS
  • FAIL
Calibration Strategy Character The strategy for performing the calibration.

This field is disabled and populated with the value in the Calibration Strategy field of the Calibration Template that is linked to this Calibration.

Calibration Task Character The identification of the Calibration Task that is linked to this Calibration.

This field is disabled and populated with the ID of the Calibration Task that is associated with the Calibration.

Calibration Technician Character The name of the person who is responsible for performing the calibration.

You can modify this value by selecting a user from the list.

Calibration Template Key Numeric The ID of the Calibration Template linked to the Calibration.

This field is disabled and populated with the ID of the Calibration Template that is associated with the Calibration.

This field is labeled Select Calibration on the datasheet.

Calibration Type Character The type of calibration event.

This field is disabled and populated with the value CMX.

Event End Date Date The date on which you have completed the calibration.

This field is populated with the current date and time.

This field is labeled Calibration End Date on the datasheet. You can modify this value if needed.

Event ID Character The identification of the calibration event. This field is disabled and populated with a default value.
Event Long Description Character Any comments on the calibration that you have performed.

This field is populated with the value in the Comments field of the calibration in the Beamex CMX calibration software.

This field is labeled Comments on the datasheet.

Equipment Manufacturer Character The manufacturer of the equipment that you have calibrated.

This field is populated with the value stored in the Manufacturer field in the Equipment that is linked to the Calibration.

This field is labeled Instrument Manufacturer on the datasheet. You can modify this value if needed.

Equipment Model Number Character The model number of the asset that you have calibrated.

This field is populated with the value stored in the Model Number field in the Equipment that is linked to the Calibration.

This field is labeled Instrument Model Number on the datasheet. You can modify this value if needed.

Event Start Date Date The date on which you have started calibrating the asset.

This field is populated with the current date and time.

This field is labeled Calibration Start Date on the datasheet. You can modify this value if needed.

Equipment Serial Number Character The serial number of the asset that you have calibrated.

This field is populated with the value stored in the Equipment Serial Number field in the Equipment that is linked to the Calibration.

This field is labeled Instrument Serial Number on the datasheet. You can modify this value if needed.

Location ID Character The physical location where you have performed the calibration. You can enter a value manually.
Location Short Description Character A description of the location where you have performed the calibration. You can enter a value manually.
Scheduled Calibration Date Date The date on which the calibration is scheduled to be performed. You can enter a value manually.
Off Line Duration Numeric A number representing the amount of time in hours that passed between the time the calibration was initiated and the time that it was completed. You can enter a value manually.
Overall AF Pass/Fail Character A value that indicates whether the calibration passed or failed based on whether the As Found values fall within the range of values specified in the record.

In automated calibration, this field is populated based on the calibration results that are received from the Beamex CMX calibration software.

In manual calibration, you can select one of the following values that are defined in the MI_CALIBRATION_RESULT System Code Table, to indicate the result of calibration:

  • PASS
  • FAIL
Overall AF Error Max Numeric A number that corresponds to the highest error value recorded from all the As Found values.

In automated calibration, this field is populated based on the calibration results that are received from the Beamex CMX calibration software.

In manual calibration, you can enter a value manually.

Overall AL Error Max Numeric The highest error value recorded from all the As Left values.

In automated calibration, this field is populated based on the calibration results that are received from the Beamex CMX calibration software.

In manual calibration, you can enter a value manually.

Overall AL Pass/Fail Character A value that indicates whether the calibration passed or failed based on whether the As Left values fall within the range of values specified in the Calibration.

In automated calibration, this field is populated based on the calibration results that are received from the Beamex CMX calibration software.

In manual calibration, you can select one of the following values that are defined in the MI_CALIBRATION_RESULT System Code Table, to indicate the result of calibration:

  • PASS
  • FAIL

WO Reference Character The work order number associated with the calibration event. You can enter a value manually.