108443093

Features

Legacy ESM solutions backed by 10 years of exhaust spread monitoring experience

  • More robust combustion spread monitoring and thermocouple adjacency logic
  • Less conservatism in response to faults in adjacent thermocouples; two adjacent faults are allowed indefinitely, while three adjacent faults cause a protective shutdown after one hour
  • Improved running reliability and longer response time to address thermocouple faults
  • Time-delayed runback action on adjacent TC failure instead of instant trip
  • Reliance on flame detector inputs removed

 

Webinar

91M+ operating hours of insight: F-class reliability solutions

Sep 4, 2025 | 3pm MYT, 11am Berlin, 11am NYC

With over 1.6 million starts across 1,350+ F-class gas turbines, GE Vernova has gained deep insight into reliability challenges. Join our webinar to learn how we can help you reduce trips and failed starts with proven solutions.

Mohamed Sayed

Customer Application Engineering, GE Vernova

Noora AlAmiri

Lead Upgrade Sales Manager for Gulf, GE Vernova

Houssem Zoghmar

Service Engineering Leader, GE Vernova

f-class-valve-reliability-image.jpg

Save time and money with F-class reliability upgrades

We’ve drawn on millions of hours of fleet data and created a solution to keep you running and preserve revenue. In fact, 40% of reported F-class reliability issues could have been prevented with valve and instrumentation upgrades.

Contact us

Talk to an expert about this reliability upgrade for your units